IRC R401.3: grading the lot so water leaves the house

Section R401.3 is the grading rule that most directly touches a landscaper. It says how fast the ground must fall away from the foundation and what to do when it cannot. These are the figures, with the edition each one comes from.

Quick answer

Sources describing R401.3 give a minimum final grade of 6 inches of fall within the first 10 feet, which one source calls 5 percent, with a swale or drain as the alternative where that is impossible. Patios, walks and driveways within 10 feet of the foundation need at least a 2 percent slope away. Figures come from the 2015 and 2024 editions; confirm 2021 text.

The grading figures

RuleFigure as statedSource and edition
Slope away from foundationAt least 6 inches of fall within the first 10 feet. ICC calls this a minimum final grade of 5 percent.ICC TN04 (2015 IRC); InterNACHI (2024 IRC)
Where it will not fitDrains or swales may be used to direct water away from the foundation when lot lines or steep slopes prevent the 6-inch drop.InterNACHI (2024 IRC); ICC TN04 mentions drains or swales as the alternative
Impervious surfacesPatios, walks and driveways within 10 feet of the foundation need a slope of at least 2 percent away, described by ICC as 1/4 inch of drop per foot.ICC TN04 (2015 IRC); InterNACHI (2024 IRC)
Window wellsWindow wells should connect to the foundation drainage system under R310.2.3.2.ICC TN04 (2015 IRC)

The two sources above describe the 2015 and 2024 editions and agree on the figures, and our own IRC rules summary lists the same 6-inch figure for 2021. That is good evidence the number has been stable, but the adopted 2021 text, any Pennsylvania amendment and the code official govern. ICC’s note does not discuss lot-line exceptions, and InterNACHI does not give swale dimensions or the exception’s exact conditions.

Reading 6 inches in 10 feet

Six inches over ten feet is half an inch of fall per foot, which ICC states equals a 5 percent grade. That is a minimum measured on final grade, after mulch, topsoil and sod are in place, not on the rough grade you cut before finish materials. A common field mistake is to meet the number at rough grade and then lose it under several inches of mulch or compost placed against the house. Check the finished surface with a string line and a level, or a laser, before you leave. Our guides on regrading away from a foundation and the slope ratio chart help convert between percent and inches per foot.

Patios, walks and driveways within 10 feet

Hard surfaces shed water instead of absorbing it, so the sources hold them to a lower slope that still directs water away: at least 2 percent, or 1/4 inch of drop per foot, for impervious surfaces within 10 feet of the foundation. For a paver patio against a house this is the number the base has to be built to. A patio built dead level, or tilted toward the wall, sends every rainstorm to the foundation. Setting the slope into the base, not trying to correct it in the bedding layer, is the sound approach, and our drainage guide covers the build side.

When the slope cannot be achieved

Lot lines, neighboring walls and steep slopes can make 6 inches in 10 feet impossible. InterNACHI describes the code response as using drains or swales to redirect water away from the structure; ICC likewise says to use sufficient drains or swales. Neither source gives swale dimensions or the formal conditions of the exception, so the design and approval come from the plans and the code official. Our guide on building a drainage swale covers practical depth, width and slope, and our page on Pennsylvania drainage law covers what you may do with runoff that crosses onto a neighbor’s land.

Where grading meets the foundation drain

Grading and foundation drains do different jobs. Grading moves surface water away from the wall. Drains deal with groundwater at the footing. ICC TN04 says foundation drainage is required for basements and crawl spaces with floors below exterior grade unless the soil is a well-drained Group I soil. See our page on R405.1 and R406 foundation drains and waterproofing. Downspouts matter too: a good grade is wasted if the gutter discharge dumps at the wall. Our article on how far downspouts should extend and the wet basement exterior fixes go into that.

A correction to a common claim

Some people remember the grading rule as a 10 percent slope for 10 feet. The sources do not say that. They give 6 inches of fall in 10 feet, which ICC equates to 5 percent. A steeper grade is not prohibited by those sources, but it is not what they state as the minimum.

What to check before you leave a job

  • Measure fall from the foundation outward for 10 feet on finished grade, not rough grade.
  • Check any patio, walk or driveway within 10 feet for at least 2 percent away from the house.
  • Confirm the soil is not mounded against siding or sills by mulch.
  • Confirm window wells connect to the drainage system where one exists.
  • Where the slope cannot be met, confirm the swale or drain is on the approved plan.
Which edition applies. Pennsylvania’s Uniform Construction Code moved to the 2021 International Codes on January 1, 2026, according to a Manheim Township code memo and a Lower Merion Township notice (checked Nov. 23, 2026). Those notices say a project with a design or construction contract signed before January 1, 2026 could stay on the 2018 codes if the permit application was filed by June 30, 2026, and that from July 1, 2026 all projects are reviewed under the 2021 codes. The PA L&I UCC page confirms a Triennial Update approved October 16, 2025, published November 8, 2025 and effective January 1, 2026, but does not name editions. L&I’s regulations page still described the 2015 codes and warned it may be out of date, and a public copy of 34 Pa. Code § 403.21 still lists the 2018 IRC. Pennsylvania’s own amendments to the 2021 IRC are in the November 8, 2025 Pennsylvania Bulletin, so this page does not state any PA amendment. The adopted edition, any local amendments and your code official govern.
Planning information, not legal or engineering advice. This page paraphrases the model code and does not reproduce it. Table values, exceptions and local amendments are in the adopted text. The code official decides what your project needs; use a licensed design professional where the prescriptive path may not apply.

Questions

What slope does the IRC require away from a foundation?

Sources describing R401.3 give a minimum final grade of 6 inches of fall within the first 10 feet, which ICC equates to 5 percent. Those sources cover the 2015 and 2024 editions; confirm the adopted 2021 text.

How much slope does a patio need near the house?

The sources give at least 2 percent away from the foundation, about 1/4 inch of drop per foot, for impervious surfaces within 10 feet of the foundation.

What if I cannot get 6 inches of fall in 10 feet?

The sources say drains or swales may be used to carry water away from the foundation. They do not give swale dimensions, so confirm the design with the code official.

Is the rule 10 percent?

No. The sources give 6 inches in 10 feet, which ICC calls 5 percent, for the minimum final grade.

Sources: ICC Technical Note TN04, Rain and Groundwater Management (2015 IRC, p. 2); InterNACHI, Foundation Fundamentals: Inspecting Load Paths and Water Paths (cites 2024 IRC Chapter 4); Manheim Township, Code Change Memo 2026; Lower Merion Township, 2021 I Codes go into effect; PA L&I, Uniform Construction Code; PA L&I, UCC regulations and statutes. Checked Nov. 23, 2026.

Muthler Landscaping & Construction · Lock Haven, PA

Planning site work in central PA?

We do excavation, grading, drainage and hardscape across Clinton, Centre, Lycoming and Union counties. Tell us what you have in mind.

Get a free estimatePennsylvania guide

Muthler Landscaping & Construction LLC · 913 Bellefonte Ave, Lock Haven, PA 17745 · (570) 397-9800 · PA HIC #PA212584.

Using this guide? Link to it or cite it. It’s free to use with a link back, and we keep it updated against official sources.

Cite as: Muthler Landscaping & Construction, “IRC R401.3 Lot Grading: 6 Inches in 10 Feet, Explained,” https://muthlerlandscaping.com/state-guides/pennsylvania/irc-r401-3-lot-grading-drainage-away-from-house/ (page updated November 23, 2026).