Pennsylvania Construction Code Act Section 105: Department of Labor and Industry Review, State Buildings, Elevators and Health Care Facilities
Most of Pennsylvania’s Construction Code Act (Act 45 of 1999, 35 P.S. 7210.101 et seq.) is about local permits, but Section 105 is about the state agency behind the Uniform Construction Code (UCC). It sets out what the Department of Labor and Industry can do when a municipality or code official is not doing the job, who handles State-owned buildings, who controls elevators, and what happens to health care facilities. A contractor rarely cites Section 105 directly, yet it explains why an elevator is sealed by the state and not the town, and why a hospital project follows a different path. This page walks through the section as the General Assembly publishes it, checked November 23, 2026. Verify every detail against the current statute text.
Quick answer
- 105(a): the Department may review municipalities and code officials where there is reasonable cause, report to the local governing body, and enforce compliance through Commonwealth Court
- 105(b): the Department keeps plan review and inspection authority over State-owned buildings; municipalities notify it of inspections of political-subdivision buildings
- 105(c): the Department has statewide authority over elevators and conveying systems
- 105(d): health care facilities stay under their licensure codes, and plan review may be delegated to the Department of Health
- 105(e): the act may not restrict builders’ right to compete for commercial construction contracts
What does Section 105(a) let the Department do about municipalities?
Subsection (a) is the oversight clause. The Department may review a municipality, and the code officials working for it, when it has reasonable cause to do so. After a review it reports to the local governing body with recommendations. If a municipality still does not comply, the Department may enforce compliance by going to Commonwealth Court. For a contractor, the practical point is that the UCC is a statewide code and the Department has a statewide oversight role. How a town chooses to enforce the code in the first place is covered on our Section 501 enforcement options page and our opt-in and opt-out guide.
Who reviews State-owned and local government buildings under 105(b)?
Subsection (b) splits public buildings into two groups. For buildings owned by the Commonwealth, the Department keeps its own plan review and inspection authority, so a State project is not sent to the local code office. For buildings owned by a political subdivision, such as a township, borough or school district, the municipality must notify the Department of inspections. The wording does not say a municipality loses its role over its own buildings; it says the Department is told. If you bid public work, ask the owner early who reviews the plans and who inspects, because the answer changes where you send drawings and when you can schedule a final inspection. Public bids can also bring wage and bonding rules that are separate from the UCC, such as those on our prevailing wage page.
How does Section 105(c) treat elevators and conveying systems?
Elevators are the one area where the state, not the town, holds the authority. The Department has statewide authority over elevators and conveying systems. It may modify certain referenced standards from the 1999 BOCA code, and it may not require reshackling more than once every two years. Third-party elevator inspections remain allowed. A related rule sits in the regulations: 34 Pa. Code 403.84(f) says the Department may seal an elevator for an unsafe condition under section 105(c)(1) of the act, that only the Department may remove the seal, and that it does so only after the owner corrects the condition or authorizes removal. That means a local building official cannot sign off on a sealed elevator, and a contractor repairing one needs to deal with the Department. Our third-party agencies page explains the separate role of private inspection agencies.
What happens to health care facilities under 105(d)?
Health care facilities continue under their own licensure codes. The Department may delegate their plan reviews to the Department of Health. Section 104(d), covered on our Section 104 page, separately says licensing and federal certification rules for health care facilities are not preempted by the act. Read together, a clinic, nursing facility or hospital addition may need approval from the health agency in addition to, or in place of, the usual local plan review. Ask the agency which approvals replace which before you price the job. The permit application rule at 34 Pa. Code 403.42a(n) also lists the Health Care Facilities Act among other laws whose permit, certification or licensure rules the applicant must still follow.
What does 105(e) say about competing for commercial work?
Subsection (e) is a short limitation. Nothing in the act may restrict builders’ right to compete for commercial construction contracts. It is easy to overread. It does not say a builder is exempt from the UCC, and it does not stop a town from licensing workers under Section 104(e). It says the act itself is not a tool for closing the market. If a local rule seems to shut out outside builders from commercial bids, whether it conflicts with Section 105(e) is a legal question for a Pennsylvania attorney.
| Subsection | Subject | What the section says |
|---|---|---|
| (a) | Review of municipalities | Reasonable-cause review, report to the governing body, Commonwealth Court enforcement |
| (b) | Public buildings | Department reviews and inspects State-owned buildings; municipalities notify it of local government building inspections |
| (c) | Elevators | Statewide authority; reshackling no more than once every two years; third-party inspections allowed |
| (d) | Health care facilities | Licensure codes continue; review may be delegated to the Department of Health |
| (e) | Competition | Act may not restrict the right to compete for commercial contracts |
What owners and contractors can do with Section 105
- On State-owned or school or township projects, ask the owner who reviews plans and who inspects before you submit anything.
- On any elevator or lift work, plan on the Department, not the local office, as the authority.
- On health care work, ask both the local code office and the health agency which approvals apply.
- If a code office keeps missing deadlines, ask a Pennsylvania attorney what options exist; Section 105(a) describes the Department’s review role, not a complaint procedure.
- Keep written copies of every approval, because the same project may touch more than one agency.
Sources
Construction Code Act, Act 45 of 1999, Section 105, text published by the Pennsylvania General Assembly (PDF); 34 Pa. Code 403.84 (Cornell LII) and 403.42a (Cornell LII). Checked Nov. 23, 2026. Verify against the current statute text, since the act has been amended.
FAQ
Can the state review a municipality’s building code office?
Section 105(a) lets the Department of Labor and Industry review municipalities and code officials with reasonable cause, report to the local governing body, and enforce compliance through Commonwealth Court. Verify the current text.
Who inspects elevators in Pennsylvania under the Construction Code Act?
Section 105(c) gives the Department statewide authority over elevators and conveying systems, and third-party elevator inspections remain allowed. Check the current text and ask the Department about a specific unit.
Does the local code office review State-owned building plans?
Section 105(b) says the Department keeps plan review and inspection authority over State-owned buildings. For political-subdivision buildings, municipalities must notify the Department of inspections.
Are health care facilities covered by the UCC permit process?
Section 105(d) says health care facilities continue under their licensure codes and the Department may delegate plan review to the Department of Health. Ask both agencies which approvals apply, and consult an attorney on a specific project.
This is a plain-English summary of what the official sources state, not legal advice. Statutes get amended and courts interpret them, so talk to a Pennsylvania attorney about your own situation before you rely on any of it.
Related: Pennsylvania guide · Section 103 definitions · Pennsylvania building code · UCC opt-in vs opt-out.
Using this guide? Link to it or cite it. It’s free to use with a link back, and we keep it updated against official sources.
Cite as: Muthler Landscaping & Construction, “Pennsylvania Construction Code Act Section 105: Department of Labor and Industry Review, State Buildings, Elevators and Health Care Facilities,” https://muthlerlandscaping.com/state-guides/pennsylvania/construction-code-act-section-105-department-review-state-buildings-elevators/ (page updated November 23, 2026).
Get an email when your state’s rules change
We re-check every entry against official sources. Tell us your state and we’ll email you when something changes.