Skip to content Groundwork Design Co.Want a design?Custom patio, wall, deck and yard plans, drawn by builders. Anywhere in the U.S. From $349.Start here
LOCK HAVEN, PA · PA HIC #PA212584 · INSURED FREE ESTIMATES · CALL OR TEXT
PAGE

34 Pa. Code 403.21: The Pennsylvania UCC, Which 2021 I-Codes Are Adopted and Key Residential Changes

Pennsylvania does not write its own building code from scratch. Section 403.21 of Title 34 of the Pennsylvania Code adopts a set of International Code Council model codes by reference and calls the result the Uniform Construction Code (UCC), with listed exceptions and swaps. If you build decks, additions, stairs or foundations, this is the section that tells you which edition of which code applies and where Pennsylvania departs from the model text. This page walks through the section as shown on Cornell’s Legal Information Institute and checked November 23, 2026. The section has many cross-references, so verify every number and section reference against the current regulation. Our page on Construction Code Act sections 301 to 305 covers the statute behind this rule.

Quick answer

  • 403.21(a): the Department adopts the listed model codes by reference as the UCC, mainly 2021 editions, with exceptions and modifications
  • Stairs: maximum riser height 8 1/4 inches and minimum tread depth 9 inches for IRC and R-3 stairs
  • Smoke alarms: interconnection under IRC R314.4 does not apply to alterations, repairs or additions to one- and two-family dwellings; battery alarms are used instead
  • 403.21(b): if the UCC and the adopted codes differ, the UCC controls
  • 403.21(e): individual sewage disposal systems are governed by 25 Pa. Code Chapter 73

Which codes does 403.21(a) adopt?

Under subsection (a), the Department adopts these model codes by reference, each with its own exceptions:

ItemCode adopted
(a)(1)International Building Code (IBC) 2021 (Chapters 2 to 10, 12 to 29 and 31 to 35), with listed exceptions and modifications
(a)(2)Chapter 11 of the IBC 2021 (accessibility)
(a)(3)International Mechanical Code 2021
(a)(4)International Fuel Gas Code 2021
(a)(5)International Performance Code for Buildings and Facilities 2021
(a)(6)International Plumbing Code (IPC) 2021, with exceptions
(a)(7)International Residential Code (IRC) 2021, with provisions
(a)(8)International Fire Code 2021, only to the extent other adopted codes reference it
(a)(9)International Energy Conservation Code (IECC) 2021, with provisions
(a)(10)International Existing Building Code (IEBC) 2021, with exceptions
(a)(11)International Wildland-Urban Interface Code 2021
(a)(12) and (a)(13)Appendix E of the IBC 2018 and Appendix H of the IBC 2009
(a)(14)International Swimming Pool and Spa Code 2021

Notice the mixed editions. The base is 2021, but Pennsylvania keeps Appendix E of the IBC from 2018, Appendix H of the IBC from 2009 and some provisions from earlier editions. That is why a contractor cannot simply buy the 2021 residential code and stop reading. The adopted-code list also explains why a building department asks which edition governs a question. For deck work, our deck post height and bracing page and beam sizing page rely on the residential code.

What does Pennsylvania change in the residential code?

Subsection (a)(7) is the one most home builders care about. The most useful items:

  • Smoke alarms: the interconnected requirement in R314.4 does not apply to one- and two-family dwellings undergoing alterations, repairs or additions. Those dwellings install non-interconnected battery-operated smoke alarms instead.
  • Stair riser and tread: maximum riser height of 8 1/4 inches, with variation within a flight limited to 3/8 inch; minimum tread depth of 9 inches measured nosing to nosing, with variation limited to 3/8 inch.
  • Nosing: uniform tread projection limited to 1 1/2 inches when solid risers are used.
  • Stair width and headroom: minimum clear width of 3 feet with 6 feet 8 inches of clear headroom along the full run, and handrails may project 3 1/2 inches into the required width.
  • Crawl spaces: R408.3 requires dehumidification sized to the manufacturer’s specifications for unvented crawl spaces.
  • Stucco: R703.7 requires compliance with ASTM C926-2018B and C1063-2018B.
  • Attic and roof ventilation: R806.1 requires ventilation openings to open directly to outside air, and R806.3 requires that nothing block the free flow of air where eave or cornice vents are installed.
  • Foyer receptacles: E3901.11 changes a 3-foot spacing to 6 feet and requires at least one receptacle.
  • Energy: the Climate Zone 3 fenestration U-factor in Table N1102.1.2 is set to 0.35.

The section also lists a long run of IRC 2021 sections that are excluded or modified, with some provisions kept from earlier editions. We did not reproduce that list. Pennsylvania picks and chooses by section, so the section number in a plan note should always be checked against 403.21 before you assume it applies. Also remember that the stair numbers above matter for steps to a deck or patio; see our page on work that does not need a UCC permit for the separate question of whether a permit is needed at all.

What about plumbing, energy and the existing building code?

For plumbing, subsection (a)(6) says a municipality in a second-class county may not administer or enforce the IPC under this chapter, and that such a municipality with its own plumbing code under the Local Health Administration Law keeps the authority to enforce it and make changes, provided the changes meet UCC minimums. For energy, subsection (d) lets a permit applicant use prescriptive compliance methods based on climate zone: for detached residential buildings, the IECC 2021 compliance guide (REScheck) or Pennsylvania’s Alternative Residential Energy Provisions, and for all other buildings the IECC 2021 compliance guide (COMcheck). For repairs, alterations, changes of occupancy, additions and relocations of existing buildings, subsection (f) says they must comply with IBC 2021 Chapter 34 or the IEBC 2021.

Conflicts, appendices and sewage

Subsection (b) says the fire code under (a)(8) is part of the UCC only to the extent the IBC 2021 Chapter 35 references it, and that if the UCC and the adopted codes differ, the UCC controls. For conflicts involving administrative provisions in the incorporated codes, the chapter’s administrative provisions govern under 403.27(e). Subsection (c) says appendices are not adopted, except for the appendices and resource information in the IEBC 2021 and the appendices listed in (a)(12) and (a)(13). Subsection (e) says individual sewage disposal systems are governed by 25 Pa. Code Chapter 73, which is why septic questions are handled under environmental rules, not the building code; see our page on Act 537 sewage facilities planning.

How to use this section on a job

  • Ask your code office which edition and which Pennsylvania modifications they apply before you draw plans.
  • Do not take a stair detail from a generic internet source; use the Pennsylvania figures and verify them.
  • For alterations to an existing home, check the smoke alarm rule so you install the right type.
  • For an unvented crawl space, plan the dehumidification the manufacturer specifies.
  • Keep a copy of the energy compliance report your method produces.

Limits of this summary

This page summarizes a very long section and may have shortened or reordered items. The section has been amended many times, most recently by a final-omitted rulemaking published in the Pennsylvania Bulletin on November 8, 2025 (IRRC Regulation #12-125), effective January 1, 2026, and Pennsylvania may adopt newer I-Code editions later, so check that the editions above are still current. This page does not cover the underlying model code text. Code interpretation on a specific project belongs with your building code official, your design professional and, for legal disputes, a Pennsylvania attorney.

Sources

34 Pa. Code 403.21 (Cornell LII); final regulation, IRRC Regulation #12-125 (IRRC), published as final Nov. 8, 2025, effective Jan. 1, 2026. The Cornell LII copy had not yet reflected the 2025 amendment when checked Nov. 23, 2026. Verify against the current regulation text.

FAQ

Which edition of the residential code does Pennsylvania use?

Under 403.21(a)(7), the International Residential Code 2021, with listed Pennsylvania exclusions, modifications and substitute provisions from earlier editions.

What are the Pennsylvania stair riser and tread limits for houses?

A maximum riser height of 8 1/4 inches and a minimum tread depth of 9 inches measured nosing to nosing. Verify the current text.

Do smoke alarms have to be interconnected when I remodel a house?

Not for alterations, repairs or additions to one- and two-family dwellings; those install non-interconnected battery-operated smoke alarms instead, under subsection (a)(7)(i).

Who controls if the UCC and the model code disagree?

Subsection (b) says the UCC controls if it differs from the adopted codes.

This is a plain-English summary of what the official sources state, not legal advice. Regulations get amended and agencies and courts interpret them, so talk to a Pennsylvania attorney about your own situation before you rely on any of it.

Related: Pennsylvania guide · Work that doesn’t need a UCC permit · Pennsylvania building code · UCC opt-in vs opt-out.

Using this guide? Link to it or cite it. It’s free to use with a link back, and we keep it updated against official sources.

Cite as: Muthler Landscaping & Construction, “34 Pa. Code 403.21: The Pennsylvania UCC, Which 2021 I-Codes Are Adopted and Key Residential Changes,” https://muthlerlandscaping.com/state-guides/pennsylvania/ucc-34-pa-code-403-21-adopted-codes-2021-i-codes/ (page updated November 23, 2026).