Pennsylvania Construction Code Act Sections 301 to 305: Adopted Codes, Referenced Standards and Local Code Preemption

Chapter 3 of Pennsylvania’s Construction Code Act (Act 45 of 1999, 35 P.S. 7210.101 et seq.) is where the law says which technical code builders must follow. It covers five sections: 301 on adoption by regulation, 302 on referenced standards, 303 on existing municipal codes, 304 on revised or successor codes and 305 on lateral connections. This page summarizes each, from the act as published by the General Assembly. The act names the original base code from 1999 and later editions that have been layered on through amendments and regulations. It does not tell you which edition is current in the field today; for that, see our Pennsylvania building code guide. Verify every date and number against the current statute text.

Quick answer

  • 301: the Department adopts the 1999 BOCA National Building Code, Fourteenth Edition, as the UCC, and also adopts the International Fuel Gas Code and prescriptive energy methods
  • One- and two-family choice: the applicant picks the ICC One and Two Family Dwelling Code (1998) or the UCC at plan submission, and the choice is irrevocable
  • 303: local codes weaker than the UCC must be amended; local codes adopted after July 1, 1999 are preempted
  • 304: council review begins 21 months after a new ICC edition, with regulations effective 33 months after review begins
  • Court note: the text records that Section 304(a)(3) was declared unconstitutional on October 26, 2022

What does Section 301 require the Department to adopt?

Within 180 days of the section’s effective date, the Department of Labor and Industry had to adopt the 1999 BOCA National Building Code, Fourteenth Edition, as the Uniform Construction Code. In the same 180-day window it had to adopt the International Fuel Gas Code and prescriptive energy-related methods. The regulations supersede conflicting local building codes, subject to the exceptions in the act.

Section 301 also records several targeted edits to the model codes. The 2003 International Residential Code section R313.1.1 is excluded from applying to existing dwellings undergoing alterations, while the battery-operated smoke alarm requirements are included. The 2006 International Residential Code section R404.1 is excluded and replaced by foundation-wall provisions. The International Building Code section 110.3 on temporary occupancy is adopted. These show how the General Assembly used the act itself, not only regulations, to tune the technical rules.

The one- and two-family code choice

For detached one- and two-family dwellings, one-family townhouses of up to three stories and their accessory structures, Section 301 offers a choice. The work may be built under the ICC International One and Two Family Dwelling Code, 1998 Edition, or under the UCC. The applicant must choose when submitting plans, and the choice is irrevocable. If no choice is made, the UCC applies. Because the choice cannot be undone, make it deliberately with your designer and the code official, and put the selected code on the plan sheet. The group of buildings this covers matches the residential definition explained on our Section 103 page.

Accessibility is handled differently. The Secretary has exclusive authority to grant modifications and to decide technical infeasibility for accessibility requirements, so a municipal official cannot waive them.

Section 302: referenced standards

Standards referenced in Chapters 30 and 35 of the 1999 BOCA code become part of the UCC, along with ASME/ANSI B77.1 for passenger tramways. Two items are excluded: BNPMC-96, the BOCA Property Maintenance Code, and ASME/ANSI A17.3 on existing elevators and escalators. The latest ANSI standards for ski lift operation are included. Municipalities may still adopt and enforce codes that are not referenced in the 1999 BOCA code. The text notes that this section was amended on December 1, 2004. The property maintenance exclusion is the practical point: a local property maintenance code is a separate local matter, not a UCC requirement.

Section 303: what happened to old local codes

Local ordinance situationResult under Section 303
Ordinance falls short of UCC minimumsMust be amended by the date the regulations take effect
City of the first class, ordinance adopted on or before January 1, 1998Amend by December 31, 2003
Ordinance in effect on July 1, 1999 that meets or exceeds the UCCStays in effect until it falls short
Ordinance adopted after July 1, 1999Preempted and treated as rescinded when the regulations take effect

The July 1, 1999 line explains why a municipality that wanted stricter rules after the act could not simply pass them. Later stricter rules must instead follow the notice and challenge process in Section 503, covered on our Sections 502 and 503 page.

Section 304: how new code editions get in

Section 304 sets the cycle for revised or successor codes. The Review and Advisory Council works through updated sections on a fixed clock, and the Department must then adopt its decisions.

  • Council review begins 21 months after a new ICC edition is published (Section 108).
  • A 120-day public comment period opens 30 days after review begins.
  • The council reports to the Secretary within 24 months of starting review.
  • The Department adopts the council’s decisions within nine months of the report, without change, using final-omitted rulemaking.
  • Regulations take effect 33 months after council review begins, except the 2015 Code Review regulations, which took effect October 1, 2018.
  • If an updated section is not adopted or modified, the existing provisions remain in effect.

Two transition rules protect jobs in progress. Valid permits remain valid, but a permit not actively pursued within two years, or a shorter municipal period, must be renewed. A contract signed before a new code takes effect may use the earlier code if a permit is applied for within six months, or a shorter municipal period. For a contractor, that second rule is a pricing tool: a signed contract plus a prompt permit application can lock in the older code. Confirm the municipal period first.

The act also records that the Commonwealth Court declared Section 304(a)(3) unconstitutional on October 26, 2022, in Pa. Builders Ass’n v. Dep’t of Labor, 284 A.3d 1287 (2022). This page does not address how that ruling changes the cycle in practice. If a project depends on which code edition applies, check with the Department of Labor and Industry and ask a Pennsylvania attorney.

Section 305: lateral connections

Section 305 was added on December 1, 2004. It preserves municipal or authority standards for lateral connections on private property that tie into public infrastructure, if the standards were in place on January 1, 2005, and meet or exceed the UCC, the International Residential Code or the International Plumbing Code. They must be amended once they fall short, and qualifying standards must be filed with the Department and with any local governments the municipality or authority serves. For sewer and water tie-ins, ask the local authority for its standard.

Sources

Construction Code Act, Act 45 of 1999, Sections 108 and 301 through 305, text published by the Pennsylvania General Assembly (PDF). Checked Nov. 23, 2026. Verify against the current statute text, especially the court citation.

FAQ

Can a builder switch codes after choosing for a one- or two-family house?

No. Section 301 says the choice between the ICC One and Two Family Dwelling Code (1998) and the UCC is made at plan submission and is irrevocable.

Can a town keep its own building code?

Under Section 303, ordinances in effect on July 1, 1999 that meet or exceed the UCC stayed in effect until they fall short, and ordinances adopted after that date are preempted.

Can I use the older code if I signed my contract before a new code took effect?

Section 304 allows it if a permit is applied for within six months, or a shorter municipal period. Confirm the local period with the code office.

When do new ICC code editions take effect in Pennsylvania?

The act sets review 21 months after a new ICC edition and regulations effective 33 months after review begins. A 2022 court ruling affected Section 304(a)(3), so check with the Department.

This is a plain-English summary of what the official sources state, not legal advice. Statutes get amended and courts interpret them, so talk to a Pennsylvania attorney about your own situation before you rely on any of it.

Related: Pennsylvania guide · Pennsylvania building code · Section 103 definitions · UCC opt-in vs opt-out.

Using this guide? Link to it or cite it. It’s free to use with a link back, and we keep it updated against official sources.

Cite as: Muthler Landscaping & Construction, “Pennsylvania Construction Code Act Sections 301 to 305: Adopted Codes, Referenced Standards and Local Code Preemption,” https://muthlerlandscaping.com/state-guides/pennsylvania/construction-code-act-sections-301-305-adopted-codes-preemption/ (page updated November 23, 2026).