State guides · Pennsylvania · Deck code
Deck post height limits and bracing
A tall deck post is a column that can buckle and a lever that can sway. The American Wood Council’s DCA 6 guide limits post height by species, beam span and joist span in its Table 4, and it sets a bracing rule for corner posts. Here is what the guide says, and how the numbers change as a deck gets taller and wider.
In the AWC guide (2015 edition, p. 10) posts must be at least 6×6 nominal, and 8×8 posts may replace them anywhere in Table 4 up to 14 ft high. Corner posts over 2 ft high need diagonal bracing parallel to the beam. Height runs from grade, or the top of the foundation if higher, to the underside of the beam. Checked Nov. 23, 2026.
Post rules by section
| Item | What the source states | Source and edition |
|---|---|---|
| Minimum size | At least 6×6 nominal. 8×8 posts may replace them anywhere in Table 4, up to 14 ft high. | AWC DCA 6, 2015 edition, p. 10 |
| How height is measured | From grade, or the top of the foundation if that is higher, to the underside of the beam. | AWC DCA 6, 2015 edition, p. 10 |
| Footing position | Posts are centered on their footings. | AWC DCA 6, 2015 edition, p. 10 |
| Beam connection | Notch the post (Fig. 8A) or use a post cap (Fig. 8B). All 3-ply beams need a post cap. Attaching to the side of an un-notched post is prohibited (Fig. 9). | AWC DCA 6, 2015 edition, p. 10 |
| Bracing | Diagonal bracing parallel to the beam at corner posts over 2 ft high; not used on center posts; fastened with 1/2 in. lag screws. | AWC DCA 6, 2015 edition, p. 10 |
| Lateral restraint (code view) | Manufactured connectors, or at least 12 in. of post embedment in surrounding soil or concrete piers (R507.4.1). | Penn State handout, 2018 IRC, slide 35 |
| Footing depth (code view) | Extends below the frost line in Table R301.2(1) (R507.3.2). | Penn State handout, 2018 IRC, slide 37 |
Sample rows from Table 4 (DCA 6, 2015 edition, p. 12)
Table 4 gives the maximum post height in feet for each species group, along with the footing size the guide pairs with that beam and joist span. LB is the beam span and LJ is the joist span. The columns are southern pine (SP), Douglas fir-larch (DF-L), hem-fir and western cedars (HF/WC), redwood, and ponderosa pine, red pine and SPF (PP/RP/SPF). These are selected rows only.
| Beam span | Joist span | SP | DF-L | HF/WC | Redwood | PP/RP/SPF | Round footing | Square footing | Thick |
|---|---|---|---|---|---|---|---|---|---|
| 6 ft | to 10 ft | 14 | 14 | 14 | 14 | 14 | 18 in. | 16×16 in. | 7 in. |
| 6 ft | to 14 ft | 14 | 14 | 14 | 14 | 14 | 21 in. | 18×18 in. | 8 in. |
| 6 ft | to 18 ft | 14 | 14 | 12 | 14 | 11 | 24 in. | 21×21 in. | 10 in. |
| 12 ft | to 10 ft | 14 | 14 | 12 | 14 | 10 | 25 in. | 22×22 in. | 10 in. |
| 12 ft | to 14 ft | 13 | 12 | 9 | 11 | 5 | 30 in. | 26×26 in. | 13 in. |
| 12 ft | to 18 ft | 11 | 9 | 6 | 9 | 2 | 34 in. | 30×30 in. | 15 in. |
| 18 ft | to 10 ft | 12 | 11 | 8 | 11 | 2 | 31 in. | 27×27 in. | 13 in. |
| 18 ft | to 14 ft | 9 | 8 | 2 | 8 | NP | 37 in. | 33×33 in. | 16 in. |
| 18 ft | to 18 ft | 5 | 2 | 2 | 6 | NP | 42 in. | 37×37 in. | 19 in. |
Table assumptions: 40 psf live load, 10 psf dead load, No. 2 grade lumber, wet service, 1,500 psf soil, 150 pcf concrete and 2,500 psi concrete. Multiply the footing size by 0.9 for corner posts. “NP” appears in the table for some species at the longest spans; confirm the table key in the PDF. Check any number you build from against the page.
Reading the pattern
At a 6 ft beam span nearly every species reaches 14 ft. At 18 ft, the same joist span drops the southern pine limit to 12 ft or less, and some species fall to 2 ft.
Read down any beam-span block. As the joist span grows from 10 to 18 ft, the permitted post height falls and the footing grows, because the post carries more deck area.
Southern pine and Douglas fir-larch hold height best in these rows. Ponderosa pine, red pine and SPF are the first to hit the table’s limits, so a bundle of lumber changes the answer.
Practical notes from the field
Measure post height the way the guide does. A deck over a sloped yard has posts of different heights, and the tallest post sets the row you read. Take the height from grade, or from the top of a foundation if that is higher, up to the underside of the beam, not to the deck surface. The beam and decking add to the overall deck height but not to the post height in the table.
Do not skip bracing because the deck is low. The guide’s trigger is a corner post over 2 ft high, which most raised decks exceed. Brace the corner posts parallel to the beam, not the center posts, and use 1/2 in. lag screws as the guide says. Bracing does not replace the lateral connection to the house or ground; see our lateral load and hold-down page.
When the table says the post is too tall for your species, you have options that do not involve guessing: choose a stronger species group, shorten the beam span by adding a post, shorten the joist span, or have an engineer design the post. A post taller than the table is the case where a design professional earns the fee.
Related: post-to-beam connections, beam sizing and Pennsylvania frost line depth.
Questions
What size post does a deck need?
The AWC guide (2015 edition) calls for at least a 6×6 nominal post. An 8×8 post may replace it anywhere in Table 4, up to 14 ft high.
Where do you measure deck post height?
From grade, or the top of the foundation if that is higher, to the underside of the beam (DCA 6, p. 10).
Does a deck post need diagonal bracing?
The AWC guide calls for diagonal bracing parallel to the beam at corner posts over 2 ft high, fastened with 1/2 in. lag screws. It is not used on center posts.
How deep does a deck post footing go?
The AWC guide puts footings on undisturbed soil at least 12 in. below grade or below the frost line, whichever is deeper. Penn State’s handout, citing the 2018 IRC, says footings extend below the frost line in Table R301.2(1).
Sources: American Wood Council, DCA 6 (2015 edition), pp. 10-12; Penn State Housing Research Center, deck design handout (2018 IRC), slides 35-37; our IRC rules page. Checked Nov. 23, 2026.
Muthler Landscaping & Construction · Lock Haven, PA
Planning a deck in central PA?
We build decks and site work across Clinton, Centre, Lycoming and Union counties, and we handle the permits that go with them.
Get a free estimatePennsylvania guideMuthler Landscaping & Construction LLC · 913 Bellefonte Ave, Lock Haven, PA 17745 · (570) 397-9800 · PA HIC #PA212584.
Using this guide? Link to it or cite it. It’s free to use with a link back, and we keep it updated against official sources.
Cite as: Muthler Landscaping & Construction, “Deck Post Height Limits and Bracing: DCA 6 Table 4 Explained,” https://muthlerlandscaping.com/state-guides/pennsylvania/deck-post-height-limits-and-bracing/ (page updated November 23, 2026).
Get an email when your state’s rules change
We re-check every entry against official sources. Tell us your state and we’ll email you when something changes.