Do You Need a Permit for a Retaining Wall? Rules in All 50 States
Whether you need a permit for a retaining wall usually comes down to one number: 4 feet. The model residential code exempts shorter walls that don’t hold back a driveway, slope or building. But states adopt that code differently, and some have no statewide residential code at all, so the real answer depends on your state and town. Here’s the rule in all 50 states and D.C.
Quick answer
Under the International Residential Code, a retaining wall 4 feet or shorter (measured from the bottom of the footing to the top of the wall) doesn’t need a permit unless it supports a surcharge like a driveway, a slope above it or a building. Taller or surcharged walls usually need a permit, and often an engineer’s design. Your state may measure differently or leave it to your town; find yours below.
What counts as a surcharge
A surcharge is any extra load on the soil the wall is holding back: a driveway or parking area, a slope rising above the wall, a building or deck footing, a pool, or another wall above it in a terrace. Codes treat surcharged walls as structural at any height, because that load pushes much harder than flat soil.
Builder’s note: Height is measured differently from state to state. The model code measures from the bottom of the footing; Pennsylvania’s rule measures from the lowest level of grade. A wall that’s 4 feet tall above ground may already be over the line once you count the buried course and base. If you’re near 4 feet, call the building department first.
Retaining wall permit rules in all 50 states
| State | Statewide residential code | Retaining wall permit exemption |
|---|---|---|
| Alabama | 2015 IRC with Alabama amendments (Alabama Residential Building Code, eff. Oct 1, 2016). Applies only in jurisdictions that had no residential code before March 2010; those with an earlier local code may keep it. | Exempt if not over 4 ft measured from bottom of footing to top of wall, unless supporting a surcharge or impounding Class I, II or IIIA liquids (2015 IRC R105.2 as adopted; Alabama's amendments change only IRC Chapters 3, 11, 24 and 34). |
| Alaska | No statewide residential code (local adoption) | Set locally |
| Arizona | No statewide residential code (local adoption) | Set locally |
| Arkansas | 2021 IRC as Arkansas Fire Prevention Code Vol. III (Residential), eff. Jan 1, 2023 | No state-specific rule. The state's adopting rule amends parts of the code's permit chapter but lists no retaining wall change. Check with your city or county building department. |
| California | 2025 California Residential Code (Title 24, Part 2.5), based on 2024 IRC, eff. Jan 1, 2026 | Set locally. CRC Chapter 1 Division II (incl. R105.2) is not adopted by HCD except where indicated, so cities and counties adopt it, often with amendments. The CRC's R105.2 text exempts walls not over 4 ft from bottom of footing to top of wall, unless supporting a surcharge. |
| Colorado | No statewide residential code (local adoption). The 2024 IRC applies only to construction by state agencies (OSA Exhibit A, rev. 10/2026). | Set locally |
| Connecticut | 2022 Connecticut State Building Code (2021 IRC portion with CT amendments), eff. Oct 1, 2022 | Exempt if not higher than 3 ft (914 mm) measured from finished grade at the bottom of the wall to finished grade at the top, unless supporting a surcharge or impounding Class I, II or IIIA liquids (CT amendment to §105.2; towns apply the same 3 ft rule to homes under R105.2). |
| Delaware | No statewide residential code (local adoption) | Set locally |
| District of Columbia | 2017 DC Construction Codes (built on the 2015 ICC model codes, incl. IRC, amended by 12 DCMR), eff. May 29, 2020 | — |
| Florida | Florida Building Code, 8th Edition (2023), Residential volume, statewide, eff. Dec 31, 2023 (based on the 2021 IRC, according to FEMA) | No statewide height exemption: the Florida Building Code's permit-exemption list, as published by Miami-Dade and Lake County, doesn't include retaining walls. Since July 1, 2026 (HB 803, ch. 2026-63), a wall that spans several single-family, two-family or townhouse lots gets one permit for the whole project, and the new $7,500 single-family exemption doesn't apply to structural work. |
| Georgia | 2024 IRC with Georgia amendments (mandatory state minimum standard), eff. Jan 1, 2026 | Set locally. Georgia's IRC amendments delete Chapter 1 (incl. R105.2) and keep it only as a reference and guide for local governments; this amendment was carried forward for the 2024 code. |
| Hawaii | State Residential Code: 2018 IRC (as adopted by the State Building Code Council). The 2021 IRC was adopted by default without state amendments, but the counties enforce their own 2018-based codes. | Set locally (county building codes) |
| Idaho | Idaho Residential Code (2020 Edition) = 2018 IRC Parts I–III and IX with Idaho amendments. Local enforcement is optional, but jurisdictions that enforce must use the state code. | Exempt if not over 4 ft from bottom of footing to top of wall, unless supporting a surcharge or impounding Class I, II or IIIA liquids (2018 IRC R105.2 as adopted; Idaho amends only R105.2 items 7 (pools) and 11 (flag poles)). |
| Illinois | No statewide residential code. According to FEMA, jurisdictions that enforce a code must use an IRC edition published within the past 9 years. In areas without a building code, the new-home contract must adopt the IRC or a local code; the current IRC is the default (815 ILCS 670). | Set locally |
| Indiana | 2020 Indiana Residential Code (2018 IRC with Indiana amendments, 675 IAC 14-4.4) | Set locally. Indiana deletes IRC R105 (incl. the R105.2 exemption list) and replaces it with an additions-and-alterations section. |
| Iowa | 2024 IRC in the Iowa State Building Code (481 IAC 301.8, ARC 9474C, eff. Sept 10, 2025). Applies only to buildings covered by the state code under Iowa Code ch. 103A; according to FEMA, that means state-owned or state-financed buildings and cities over 15,000 without an equivalent local code. | Set locally. Iowa's adoption deletes IRC sections R103–R114 (incl. R105.2). |
| Kansas | No statewide residential code (local adoption) | Set locally |
| Kentucky | 2018 Kentucky Residential Code, 3rd Ed. (Aug 2024), based on 2015 IRC (815 KAR 7:125, eff. Dec 3, 2024) | Set locally. The state regulation says permits, inspections and certificates of occupancy are not required for a single-family dwelling unless a local ordinance requires them (815 KAR 7:125 §2(2)(a)). |
| Louisiana | 2021 IRC as amended by the Louisiana State Uniform Construction Code Council, eff. Jan 1, 2023 | Set locally. Louisiana adopts the 2021 IRC 'not including Parts I-Administrative' (LAC 17:I.107), so the IRC's R105.2 permit exemptions aren't part of the state code. |
| Maine | 2021 IRC with Maine amendments (MUBEC). The amended adoption has been enforced since Apr 7, 2025; enforcement is mandatory in municipalities of 4,000+ and optional below that. | Exempt if not over 4 ft (1219 mm) in height measured from finish grade to the top of the wall, unless supporting a surcharge (Maine replacement of IRC R105.2 item 3, 16-642 CMR ch. 5). Municipalities may add exemptions by ordinance. |
| Maryland | 2021 IRC through the Maryland Building Performance Standards. Local jurisdictions may modify it with wide discretion (according to FEMA). | Model rule by default: exempt if not over 4 ft from bottom of footing to top of wall, unless supporting a surcharge or impounding Class I, II or IIIA liquids (2021 IRC R105.2 as incorporated by COMAR 09.12.51.04, which makes no change to R105). Counties and cities may change it by local amendment, and local amendments prevail (COMAR 09.12.51.05). |
| Massachusetts | 780 CMR 10th Edition, Ch. 51 Massachusetts Residential Code (2021 IRC with MA amendments). First effective Oct 11, 2024; the only code in effect since the concurrency period ended June 30, 2025. | Exempt if not over 4 ft (1,219 mm) measured from the bottom of the footing to the top of the wall, unless supporting a surcharge (780 CMR 51.00 R105.2 item 3, 10th Edition). |
| Michigan | Michigan Residential Code based on 2021 IRC, eff. Aug 29, 2025 (replaced a code based on the 2015 IRC) | Exempt if not more than 4 ft from bottom of footing to top of wall, unless supporting a surcharge (Mich. Admin. Code R 408.30505, amending IRC R105.2). This is the wording from the code in effect until Aug. 29, 2025. |
| Minnesota | Minnesota Residential Code based on 2018 IRC (according to FEMA), part of the Minnesota State Building Code | Exempt if not over 4 ft (1,219 mm) measured from the bottom of the footing to the top of the wall, unless supporting a surcharge or impounding Class I, II or III-A liquids (Minn. R. 1300.0120, subp. 4.A.4). |
| Mississippi | According to FEMA, a statewide rule requires jurisdictions to adopt one of the three most recent IRC editions, and jurisdictions could opt out when the law passed. The International Code Council's adoption chart (Apr 2026) lists the 2024 IRC. | Set locally |
| Missouri | No statewide residential code (local adoption) | Set locally |
| Montana | 2021 IRC (ARM 24.301.154; IRC Chs. 11–14 and 16–43 deleted; last amended eff. Sept 21, 2024) | Montana adopts the 2021 IRC (ARM 24.301.154) and lists no change to its permit exemptions. Confirm the 4 ft rule with your local building department or the state Building Codes Program. |
| Nebraska | 2018 IRC as part of the state building code (Neb. Rev. Stat. 71-6403; excludes R313 and Chs. 25–33) | Set locally. Nebraska's state building code (2018 IRC) carries the model 4 ft R105.2 exemption, but counties, cities and villages administer their own codes and may amend permit and inspection provisions (Neb. Rev. Stat. 71-6406). There is no state permit program for homes. |
| Nevada | No statewide residential code (local adoption). The state's 2024 IRC adoption applies only to state-owned projects. | Set locally |
| New Hampshire | 2021 IRC as part of the NH State Building Code (RSA 155-A:1, IV), eff. July 1, 2024 (HB 1059 of 2024) | Set locally. The state code applies statewide, but building permits exist only where a town or city has adopted local enforcement; that municipality decides. |
| New Jersey | 2024 IRC (New Jersey edition) under the NJ Uniform Construction Code (N.J.A.C. 5:23-3.21), eff. Aug 17, 2026; applications may use the previous (2021) codes through Feb 17, 2027 | A permit is required for any retaining wall with a total height of 4 ft or more, and for shorter walls that have a negative impact on a foundation. Total height is the sum of all walls on the same slope, measured from bottom of footing to top of wall (N.J.A.C. 5:23-2.14(g)). Walls dedicated to the municipality, bonded under the MLUL, or reviewed by a county engineer or NJDOT are excluded. |
| New Mexico | 2021 New Mexico Residential Building Code (2021 IRC, 14.7.3 NMAC), eff. July 14, 2023; applies to work on or after Dec 14, 2023 | Exempt if the wall retains less than 36 in (915 mm) of unbalanced fill and has a total height of 6 ft or less from top of wall to bottom of footing. Walls supporting a surcharge or impounding Class I, II or III-A liquids are not exempt (14.5.2.9(B) NMAC, modifying IRC R105.2(3)). |
| New York | 2025 Residential Code of New York State (2025 Uniform Code), eff. Dec 31, 2025, with a transition period allowing the 2020 code. Based on the 2024 IRC, according to FEMA. | Not on the statewide exemption list. 19 NYCRR 1203.3's list of work exempt from building permits (small sheds, awnings, partitions, finish work, etc.) doesn't include retaining walls; local enforcement programs decide. |
| North Carolina | 2018 NC Residential Code (2015 IRC basis) remains in effect. The 2024 NC Residential Code (2021 IRC basis) was adopted, but its effective date is delayed by legislation (according to FEMA, June 2025). | Set by your county or city inspections department. State law (G.S. 160D-1110(c)) waives permits for work of $40,000 or less in a single-family home unless it involves load-bearing structures or certain other work; it doesn't address retaining walls specifically. |
| North Dakota | 2024 IRC in the North Dakota State Building Code, eff. Jan 1, 2026. Local enforcement is optional, but jurisdictions that enforce must use the state code and may amend it. | Set locally (optional local enforcement; local amendments allowed) |
| Ohio | Residential Code of Ohio (based on 2018 IRC, first printing); OAC 4101:8, Chapter 1 rule eff. July 1, 2019 | Exempt if not over 4 ft (1219 mm) measured from the bottom of the footing to the top of the wall, unless supporting a surcharge (RCO §102.10, Building item 3). |
| Oklahoma | 2024 IRC as the statewide minimum code (OAC 748:20-6), eff. Sept 14, 2026; previously the 2018 IRC | IRC R105.2 as adopted: exempt if not over 4 ft from bottom of footing to top of wall, unless surcharged or impounding Class I, II or IIIA liquids. The state adopts the code's permit chapter only where it doesn't conflict with state law or local enforcement authority. |
| Oregon | 2026 Oregon Residential Specialty Code (2024 IRC basis), eff. Oct 1, 2026 (Chapter 1 adopted by OAR 918-480-0005) | No fixed statewide height. Statewide, a permit is required for retaining walls that provide safeguards for building users, support a regulated building, or retain material that could impact a regulated building if not restrained. Cities and counties may require permits for other walls by ordinance, but not for walls 4 ft or less (bottom of footing to top of wall) unless they support an ascending slope steeper than 3:1 or a nonsoil surcharge; a higher local threshold is allowed (2026 ORSC R101.2.2 item 2). |
| Pennsylvania | 2021 IRC with PA modifications under the Uniform Construction Code, eff. Jan 1, 2026 (L&I Triennial Update, Reg. #12-125 / IRRC #3455: approved Oct 16, 2025, published in the Pa. Bulletin Nov 8, 2025). It replaced the 2018 IRC adoption that took effect Feb 14, 2022. | Exempt if not over 4 ft measured from the lowest level of grade to the top of the wall, unless the wall supports a surcharge (34 Pa. Code §403.62(c)(2)). |
| Rhode Island | RISBC-2 Rhode Island State One and Two Family Dwelling Code (2021 IRC with RI amendments, 510-RICR-00-00-2); current version eff. Dec 1, 2025 | Exempt if not over 32 in high measured from the lower finished grade to the top of the wall, unless supporting a surcharge. Any cast-in-place concrete retaining wall over 24 in requires a permit (RISBC-2 R105.2 item 3, 510-RICR-00-00-2). |
| South Carolina | 2021 IRC with SC modifications, eff. Jan 1, 2023. The 2024 SC Building Codes take effect Jan 1, 2027. | Exempt if not over 4 ft from bottom of footing to top of wall, unless supporting a surcharge or impounding Class I, II or IIIA liquids (2021 IRC R105.2 as adopted; the Council's 2021 modification index has no Chapter 1 changes). |
| South Dakota | No statewide residential code. According to FEMA, jurisdictions that adopt one must use the 2021 IRC. | Set locally |
| Tennessee | 2018 IRC with Tennessee amendments (Rule 0780-02-23-.02), eff. July 16, 2020, adopted by the State Fire Marshal. According to FEMA, jurisdictions may opt out if they enforce a code no more than 7 years older than the latest edition. | Set locally. The state's residential program requires state permits only for new one- and two-family dwellings and townhouses and for additions of 30 sq ft or more of interior space (Rule 0780-02-23-.05); retaining walls aren't covered. Cities and counties that enforce their own codes decide. |
| Texas | No code for the whole state. According to FEMA, the 2012 IRC is the residential code for municipalities, which may amend it broadly. | Set locally |
| Utah | 2021 IRC with Utah amendments (Utah Code Title 15A). HB 65 (2026) keeps the 2021 IRC while moving other codes to 2024. | Exempt if retaining less than 4 ft (1219 mm) of unbalanced fill, unless supporting a surcharge or requiring design per IRC R404.4 (HB 65 (2026) replacement of R105.2 item 3 in §15A-3-202, eff. July 1, 2026). |
| Vermont | No statewide residential code (local adoption) | Set locally |
| Virginia | 2021 Virginia Uniform Statewide Building Code (2021 IRC basis), eff. Jan 18, 2024 | Exempt if supporting less than 3 ft of unbalanced fill and not built to impound Class I, II or III-A liquids or to support a surcharge other than ordinary unbalanced fill (USBC §108.2, item 7; 13VAC5-63-80). |
| Washington | 2021 IRC with WA amendments (State Building Code), eff. Mar 15, 2024. The 2024 IRC is targeted for adoption Oct 16, 2026, effective May 3, 2027. | Exempt if not over 4 ft from bottom of footing to top of wall, unless supporting a surcharge or impounding Class I, II or IIIA liquids (2021 IRC R105.2; WA's 2021 IRC amendment insert pages contain no R105.2 change). |
| West Virginia | 2018 IRC in the WV State Building Code (87CSR4). It applies only where a city or county adopts the State Building Code. | Exempt if not over 4 ft from bottom of footing to top of wall, unless supporting a surcharge or impounding Class I, II or IIIA liquids (2018 IRC R105.2 as adopted; 87CSR4 amendments don't touch Chapter 1), in jurisdictions that adopt the code. |
| Wisconsin | Uniform Dwelling Code (Wis. Admin. Code SPS 320–325), Wisconsin's own code, not the IRC (according to FEMA) | Set locally. The Uniform Dwelling Code covers new one- and two-family dwellings and doesn't regulate retaining walls; municipalities may regulate structures outside its scope (detached buildings, fences, driveways and the like) by local ordinance (SPS 320.02(2)(c), per DSPS's UDC commentary). |
| Wyoming | No statewide residential code (local adoption) | Set locally |
State-by-state details
AlabamaOfficial source
- Residential code
- 2015 IRC with Alabama amendments (Alabama Residential Building Code, eff. Oct 1, 2016). Applies only in jurisdictions that had no residential code before March 2010; those with an earlier local code may keep it.
- Code agency
- Alabama Energy and Residential Codes Board (ADECA)
- Retaining wall exemption
- Exempt if not over 4 ft measured from bottom of footing to top of wall, unless supporting a surcharge or impounding Class I, II or IIIA liquids (2015 IRC R105.2 as adopted; Alabama's amendments change only IRC Chapters 3, 11, 24 and 34).
- Who decides
- Your city or county decides. If it had its own residential code before March 2010, that code governs; otherwise the state's 2015 IRC applies where it is enforced locally.
- Good to know
- Wall height is measured from the bottom of the footing to the top of the wall. If your city or county had its own residential code before March 2010, that code may still apply.
Sources: adeca.alabama.gov · admincode.legislature.state.al.us · fema.gov
AlaskaSecondary source
- Residential code
- No statewide residential code (local adoption)
- Code agency
- None for private homes. Alaska Housing Finance Corp. sets construction and energy standards (BEES) for homes it finances; DPS Division of Fire and Life Safety adopts the IBC.
- Retaining wall exemption
- Set locally
- Who decides
- Your city or borough decides, if it has adopted a residential code.
- Good to know
- Homes financed by Alaska Housing Finance Corp. must meet its construction and energy standards (BEES). For other homes, check with your city or borough.
ArizonaSecondary source
- Residential code
- No statewide residential code (local adoption)
- Code agency
- None (no state building code for one- and two-family homes)
- Retaining wall exemption
- Set locally
- Who decides
- Your city or county building department decides.
- Good to know
- Codes are adopted and enforced locally, and Phoenix-area communities use editions ranging from 2018 to 2024. Ask your city or county building department which rules apply.
ArkansasSecondary source
- Residential code
- 2021 IRC as Arkansas Fire Prevention Code Vol. III (Residential), eff. Jan 1, 2023
- Code agency
- Arkansas State Fire Marshal (Arkansas Department of Public Safety)
- Retaining wall exemption
- No state-specific rule. The state's adopting rule amends parts of the code's permit chapter but lists no retaining wall change. Check with your city or county building department.
- Who decides
- Your city or county building department enforces the code and decides.
- Good to know
- Check with your city or county building department before you build.
Sources: law.cornell.edu · dps.arkansas.gov · fema.gov · dps.arkansas.gov
CaliforniaSecondary source
- Residential code
- 2025 California Residential Code (Title 24, Part 2.5), based on 2024 IRC, eff. Jan 1, 2026
- Code agency
- California Building Standards Commission
- Retaining wall exemption
- Set locally. CRC Chapter 1 Division II (incl. R105.2) is not adopted by HCD except where indicated, so cities and counties adopt it, often with amendments. The CRC's R105.2 text exempts walls not over 4 ft from bottom of footing to top of wall, unless supporting a surcharge.
- Who decides
- Your city or county building department decides, and many amend R105.2 locally.
- Good to know
- The 2025 California Residential Code took effect Jan. 1, 2026. Many cities and counties amend the 4 ft exemption, so check with your local building department.
Sources: dgs.ca.gov · gocodebook.com · alpinecountyca.gov · fema.gov · dgs.ca.gov
ColoradoOfficial source
- Residential code
- No statewide residential code (local adoption). The 2024 IRC applies only to construction by state agencies (OSA Exhibit A, rev. 10/2026).
- Code agency
- None for private homes. The Office of the State Architect sets codes for state-agency construction.
- Retaining wall exemption
- Set locally
- Who decides
- Your city or county decides. The state Division of Housing covers certain hotels and multifamily buildings in no-code areas, not single-family homes.
- Good to know
- Colorado has no statewide building code, so your city or county sets the rules for single-family homes.
Sources: osa.colorado.gov · fema.gov · osa.colorado.gov
ConnecticutOfficial source
- Residential code
- 2022 Connecticut State Building Code (2021 IRC portion with CT amendments), eff. Oct 1, 2022
- Code agency
- Department of Administrative Services, Office of the State Building Inspector
- Retaining wall exemption
- Exempt if not higher than 3 ft (914 mm) measured from finished grade at the bottom of the wall to finished grade at the top, unless supporting a surcharge or impounding Class I, II or IIIA liquids (CT amendment to §105.2; towns apply the same 3 ft rule to homes under R105.2).
- Who decides
- Your town building official enforces the state code.
- Good to know
- Connecticut is stricter than the model code: 3 ft instead of 4 ft, measured from finished grade at the bottom of the wall to finished grade at the top.
Sources: prdext3.cga.ct.gov · meridenct.gov · brookfieldct.gov · fema.gov · portal.ct.gov
DelawareSecondary source
- Residential code
- No statewide residential code (local adoption)
- Code agency
- None for the residential building code (counties and municipalities adopt)
- Retaining wall exemption
- Set locally
- Who decides
- Your county or municipality decides; smaller towns usually rely on the county.
- Good to know
- Most Delaware communities use the 2015 editions of the International Codes. Smaller towns usually rely on the county, so check with your county or town building office.
District of ColumbiaSecondary source
- Residential code
- 2017 DC Construction Codes (built on the 2015 ICC model codes, incl. IRC, amended by 12 DCMR), eff. May 29, 2020
- Code agency
- DC Department of Buildings (DOB)
- Engineer required
- DOB permit guideline 2019-003 (written under the 2013 DC codes): retaining walls taller than 4 ft need the seal of a District-licensed design professional.
- Who decides
- DOB decides citywide. Its retaining-wall permit guideline requires a site plan, and an official building plat for walls higher than 48 inches (DCBC 106.1.13). Walls in public space need DDOT review; walls in historic districts need historic review.
- Good to know
- Under DOB's guideline, walls taller than 4 ft need the seal of a District-licensed design professional. The guideline dates from the 2013 codes, so confirm the current rules with DOB before you build.
Sources: dob.dc.gov · dob.dc.gov · fema.gov
FloridaCheck locally
- Residential code
- Florida Building Code, 8th Edition (2023), Residential volume, statewide, eff. Dec 31, 2023 (based on the 2021 IRC, according to FEMA)
- Code agency
- Florida Building Commission
- Retaining wall exemption
- No statewide height exemption: the Florida Building Code's permit-exemption list, as published by Miami-Dade and Lake County, doesn't include retaining walls. Since July 1, 2026 (HB 803, ch. 2026-63), a wall that spans several single-family, two-family or townhouse lots gets one permit for the whole project, and the new $7,500 single-family exemption doesn't apply to structural work.
- Who decides
- Your county or city building department decides.
- Good to know
- Florida's 9th Edition building code (2026) is pending, and the 8th Edition is still current. Check with your county or city building department before you build.
Sources: floridabuilding.org · cdn.lakecountyfl.gov · miamidade.gov · floridabuilding.org · floridabuilding.org · fema.gov
GeorgiaSecondary source
- Residential code
- 2024 IRC with Georgia amendments (mandatory state minimum standard), eff. Jan 1, 2026
- Code agency
- Georgia Department of Community Affairs (DCA)
- Retaining wall exemption
- Set locally. Georgia's IRC amendments delete Chapter 1 (incl. R105.2) and keep it only as a reference and guide for local governments; this amendment was carried forward for the 2024 code.
- Who decides
- Your city or county adopts its own administrative and permit rules and decides.
- Good to know
- Georgia leaves permit rules to cities and counties. Ask your local building department whether your wall needs a permit.
Sources: dca.georgia.gov · dca.ga.gov · fema.gov · dca.georgia.gov · dca.georgia.gov
HawaiiSecondary source
- Residential code
- State Residential Code: 2018 IRC (as adopted by the State Building Code Council). The 2021 IRC was adopted by default without state amendments, but the counties enforce their own 2018-based codes.
- Code agency
- Hawaii State Building Code Council (DAGS)
- Retaining wall exemption
- Set locally (county building codes)
- Who decides
- Your county (Honolulu, Maui, Hawaiʻi or Kauaʻi) building department decides.
- Good to know
- Each county enforces its own building code based on the 2018 IRC. Check with your county building department.
Sources: ags.hawaii.gov · ags.hawaii.gov · fema.gov
IdahoSecondary source
- Residential code
- Idaho Residential Code (2020 Edition) = 2018 IRC Parts I–III and IX with Idaho amendments. Local enforcement is optional, but jurisdictions that enforce must use the state code.
- Code agency
- Idaho Division of Occupational and Professional Licenses (Idaho Building Code Board)
- Retaining wall exemption
- Exempt if not over 4 ft from bottom of footing to top of wall, unless supporting a surcharge or impounding Class I, II or IIIA liquids (2018 IRC R105.2 as adopted; Idaho amends only R105.2 items 7 (pools) and 11 (flag poles)).
- Who decides
- Cities and counties don't have to enforce a code. If yours does, it decides and can amend some parts by ordinance.
- Good to know
- Height is measured from the bottom of the footing to the top of the wall. A 2026 law (H0643) revised how cities and counties adopt the code, effective July 1, 2026.
Sources: dopl.idaho.gov · dopl.idaho.gov · legislature.idaho.gov · legislature.idaho.gov · fema.gov · dopl.idaho.gov
IllinoisSecondary source
- Residential code
- No statewide residential code. According to FEMA, jurisdictions that enforce a code must use an IRC edition published within the past 9 years. In areas without a building code, the new-home contract must adopt the IRC or a local code; the current IRC is the default (815 ILCS 670).
- Code agency
- None for residential construction
- Retaining wall exemption
- Set locally
- Who decides
- Your municipality or county decides. In areas without a building code, the construction contract sets the code.
- Good to know
- In areas without a building code, a new-home construction contract must adopt the IRC or a local code, and the current IRC is the default. For a retaining wall, check with your municipality or county.
IndianaOfficial source
- Residential code
- 2020 Indiana Residential Code (2018 IRC with Indiana amendments, 675 IAC 14-4.4)
- Code agency
- Indiana Fire Prevention and Building Safety Commission (Indiana Department of Homeland Security)
- Retaining wall exemption
- Set locally. Indiana deletes IRC R105 (incl. the R105.2 exemption list) and replaces it with an additions-and-alterations section.
- Who decides
- Your city, town or county building department decides whether a wall needs a local permit.
- Good to know
- Indiana's code has no statewide permit exemption list, so your city, town or county decides whether a wall needs a permit.
Sources: secure.in.gov · regulations.justia.com · fema.gov · in.gov
IowaOfficial source
- Residential code
- 2024 IRC in the Iowa State Building Code (481 IAC 301.8, ARC 9474C, eff. Sept 10, 2025). Applies only to buildings covered by the state code under Iowa Code ch. 103A; according to FEMA, that means state-owned or state-financed buildings and cities over 15,000 without an equivalent local code.
- Code agency
- Iowa Department of Inspections, Appeals, and Licensing – Building Code Bureau
- Retaining wall exemption
- Set locally. Iowa's adoption deletes IRC sections R103–R114 (incl. R105.2).
- Who decides
- Your city or county building department decides.
- Good to know
- Iowa's 2024 code took effect Sept. 10, 2025, but it applies only to some buildings and has no permit exemption list. Check with your city or county building department.
Sources: legis.iowa.gov · fema.gov · mitek-us.com · dial.iowa.gov
KansasSecondary source
- Residential code
- No statewide residential code (local adoption)
- Code agency
- None for residential construction
- Retaining wall exemption
- Set locally
- Who decides
- Your city or county building department decides.
Sources: fema.gov
KentuckyOfficial source
- Residential code
- 2018 Kentucky Residential Code, 3rd Ed. (Aug 2024), based on 2015 IRC (815 KAR 7:125, eff. Dec 3, 2024)
- Code agency
- Kentucky Department of Housing, Buildings and Construction
- Retaining wall exemption
- Set locally. The state regulation says permits, inspections and certificates of occupancy are not required for a single-family dwelling unless a local ordinance requires them (815 KAR 7:125 §2(2)(a)).
- Who decides
- Only your city or county can require a permit for work at a single-family home.
- Good to know
- Kentucky doesn't require permits for work at a single-family home unless a local ordinance does. Ask your city or county whether it has one.
Sources: apps.legislature.ky.gov · fema.gov · dhbc.ky.gov
LouisianaSecondary source
- Residential code
- 2021 IRC as amended by the Louisiana State Uniform Construction Code Council, eff. Jan 1, 2023
- Code agency
- Louisiana Uniform Construction Code Commission (LUCCC; formerly the LSUCCC)
- Retaining wall exemption
- Set locally. Louisiana adopts the 2021 IRC 'not including Parts I-Administrative' (LAC 17:I.107), so the IRC's R105.2 permit exemptions aren't part of the state code.
- Who decides
- Your parish or municipal building department enforces the state code and sets its own permit rules.
- Good to know
- A proposed rule to adopt the 2024 codes was published Aug. 20, 2026 but was not yet final. Your parish or municipal building department sets its own permit rules.
Sources: icc-nta.org · brla.gov · fema.gov · luccc.louisiana.gov · doa.louisiana.gov
MaineOfficial source
- Residential code
- 2021 IRC with Maine amendments (MUBEC). The amended adoption has been enforced since Apr 7, 2025; enforcement is mandatory in municipalities of 4,000+ and optional below that.
- Code agency
- Maine Office of Community Affairs – Division of Building Codes and Standards (formerly the Bureau in the State Fire Marshal's Office)
- Retaining wall exemption
- Exempt if not over 4 ft (1219 mm) in height measured from finish grade to the top of the wall, unless supporting a surcharge (Maine replacement of IRC R105.2 item 3, 16-642 CMR ch. 5). Municipalities may add exemptions by ordinance.
- Who decides
- Your municipal code office decides. Permits are required only where a municipal ordinance requires them.
- Good to know
- Maine measures height from finish grade, not the bottom of the footing. Permits are needed only where a municipal ordinance requires them.
MarylandSecondary source
- Residential code
- 2021 IRC through the Maryland Building Performance Standards. Local jurisdictions may modify it with wide discretion (according to FEMA).
- Code agency
- Maryland Department of Labor – Building Codes Administration
- Retaining wall exemption
- Model rule by default: exempt if not over 4 ft from bottom of footing to top of wall, unless supporting a surcharge or impounding Class I, II or IIIA liquids (2021 IRC R105.2 as incorporated by COMAR 09.12.51.04, which makes no change to R105). Counties and cities may change it by local amendment, and local amendments prevail (COMAR 09.12.51.05).
- Who decides
- Your county or municipality adopts and amends the code and decides.
- Good to know
- Counties and cities can change the 4 ft rule, and their local amendments override the state standard. Check with your county or city before you build.
Sources: fema.gov · mgaleg.maryland.gov · mitek-us.com · labor.maryland.gov · regs.maryland.gov · law.cornell.edu
MassachusettsOfficial source
- Residential code
- 780 CMR 10th Edition, Ch. 51 Massachusetts Residential Code (2021 IRC with MA amendments). First effective Oct 11, 2024; the only code in effect since the concurrency period ended June 30, 2025.
- Code agency
- Board of Building Regulations and Standards (BBRS)
- Retaining wall exemption
- Exempt if not over 4 ft (1,219 mm) measured from the bottom of the footing to the top of the wall, unless supporting a surcharge (780 CMR 51.00 R105.2 item 3, 10th Edition).
- Who decides
- Your city or town building department enforces the state code.
- Good to know
- Height is measured from the bottom of the footing to the top of the wall. The 10th Edition code has been the only code in effect since June 30, 2025.
Sources: mass.gov · mass.gov · mass.gov · fema.gov · mass.gov · mass.gov
MichiganSecondary source
- Residential code
- Michigan Residential Code based on 2021 IRC, eff. Aug 29, 2025 (replaced a code based on the 2015 IRC)
- Code agency
- Michigan LARA – Bureau of Construction Codes
- Retaining wall exemption
- Exempt if not more than 4 ft from bottom of footing to top of wall, unless supporting a surcharge (Mich. Admin. Code R 408.30505, amending IRC R105.2). This is the wording from the code in effect until Aug. 29, 2025.
- Who decides
- Your local building department decides.
- Good to know
- Michigan's 2021-based code took effect Aug. 29, 2025, and the exemption shown comes from the earlier version. Check with your local building department before you build.
Sources: law.cornell.edu · law.cornell.edu · fema.gov · michigan.gov
MinnesotaOfficial source
- Residential code
- Minnesota Residential Code based on 2018 IRC (according to FEMA), part of the Minnesota State Building Code
- Code agency
- Minnesota Department of Labor and Industry (Construction Codes and Licensing)
- Retaining wall exemption
- Exempt if not over 4 ft (1,219 mm) measured from the bottom of the footing to the top of the wall, unless supporting a surcharge or impounding Class I, II or III-A liquids (Minn. R. 1300.0120, subp. 4.A.4).
- Who decides
- Your city or county building official administers the code and decides.
- Good to know
- Height is measured from the bottom of the footing to the top of the wall. Walls that support a surcharge aren't exempt.
Sources: revisor.mn.gov · fema.gov · dli.mn.gov
MississippiSecondary source
- Residential code
- According to FEMA, a statewide rule requires jurisdictions to adopt one of the three most recent IRC editions, and jurisdictions could opt out when the law passed. The International Code Council's adoption chart (Apr 2026) lists the 2024 IRC.
- Code agency
- Mississippi Building Codes Council
- Retaining wall exemption
- Set locally
- Who decides
- Your city or county decides which IRC edition and permit rules apply.
- Good to know
- Cities and counties must use one of the three most recent IRC editions unless they opted out when the law passed. Check with your city or county building department.
Sources: fema.gov · mitek-us.com
MissouriSecondary source
- Residential code
- No statewide residential code (local adoption)
- Code agency
- None for private homes (the Office of State Fire Marshal adopts codes mainly for state-owned buildings)
- Retaining wall exemption
- Set locally
- Who decides
- Your city or county building department decides.
MontanaSecondary source
- Residential code
- 2021 IRC (ARM 24.301.154; IRC Chs. 11–14 and 16–43 deleted; last amended eff. Sept 21, 2024)
- Code agency
- Montana Department of Labor & Industry – Building Codes Program
- Retaining wall exemption
- Montana adopts the 2021 IRC (ARM 24.301.154) and lists no change to its permit exemptions. Confirm the 4 ft rule with your local building department or the state Building Codes Program.
- Who decides
- Your city or county building department decides where one exists; otherwise ask the state Building Codes Program.
- Good to know
- If your area has no local building department, ask the state Building Codes Program before you build.
Sources: law.cornell.edu · fema.gov · bsd.dli.mt.gov
NebraskaSecondary source
- Residential code
- 2018 IRC as part of the state building code (Neb. Rev. Stat. 71-6403; excludes R313 and Chs. 25–33)
- Code agency
- Set by statute (Nebraska Building Construction Act)
- Retaining wall exemption
- Set locally. Nebraska's state building code (2018 IRC) carries the model 4 ft R105.2 exemption, but counties, cities and villages administer their own codes and may amend permit and inspection provisions (Neb. Rev. Stat. 71-6406). There is no state permit program for homes.
- Who decides
- Your city or county decides.
- Good to know
- The state code includes the model 4 ft exemption, but cities, counties and villages can change permit rules. There's no state permit program for homes, so check with your local building office.
Sources: nebraskalegislature.gov · fema.gov · nebraskalegislature.gov
NevadaSecondary source
- Residential code
- No statewide residential code (local adoption). The state's 2024 IRC adoption applies only to state-owned projects.
- Code agency
- None for private homes (the State Public Works Board covers state projects only)
- Retaining wall exemption
- Set locally
- Who decides
- Your city or county decides. Reno and Clark County/Las Vegas use the 2018 codes with Northern or Southern Nevada amendments, according to the American Wood Council.
- Good to know
- The state's 2024 code covers only state projects, not private homes, so your city or county rules apply.
Sources: fema.gov · awc.org · publicworks.nv.gov
New HampshireSecondary source
- Residential code
- 2021 IRC as part of the NH State Building Code (RSA 155-A:1, IV), eff. July 1, 2024 (HB 1059 of 2024)
- Code agency
- NH State Building Code Review Board (State Fire Marshal's Office, Department of Safety)
- Retaining wall exemption
- Set locally. The state code applies statewide, but building permits exist only where a town or city has adopted local enforcement; that municipality decides.
- Who decides
- Your town or city building official decides, if your municipality has adopted building-code enforcement.
- Good to know
- Permits exist only in towns and cities that have adopted local enforcement, and those towns may adopt stricter rules. Check with your town or city building official.
Sources: fema.gov · firemarshal.dos.nh.gov · firemarshal.dos.nh.gov · law.justia.com
New JerseyOfficial source
- Residential code
- 2024 IRC (New Jersey edition) under the NJ Uniform Construction Code (N.J.A.C. 5:23-3.21), eff. Aug 17, 2026; applications may use the previous (2021) codes through Feb 17, 2027
- Code agency
- NJ Department of Community Affairs – Division of Codes and Standards
- Retaining wall exemption
- A permit is required for any retaining wall with a total height of 4 ft or more, and for shorter walls that have a negative impact on a foundation. Total height is the sum of all walls on the same slope, measured from bottom of footing to top of wall (N.J.A.C. 5:23-2.14(g)). Walls dedicated to the municipality, bonded under the MLUL, or reviewed by a county engineer or NJDOT are excluded.
- Who decides
- Your municipal construction official enforces the UCC statewide rule.
- Good to know
- Terraced walls on the same slope count together toward the 4 ft limit. Guards on retaining walls are outside the state code and left to the municipal engineer.
Sources: law.cornell.edu · fema.gov · nj.gov · nj.gov · nj.gov
New MexicoOfficial source
- Residential code
- 2021 New Mexico Residential Building Code (2021 IRC, 14.7.3 NMAC), eff. July 14, 2023; applies to work on or after Dec 14, 2023
- Code agency
- NM Regulation and Licensing Department – Construction Industries Division (CID)
- Retaining wall exemption
- Exempt if the wall retains less than 36 in (915 mm) of unbalanced fill and has a total height of 6 ft or less from top of wall to bottom of footing. Walls supporting a surcharge or impounding Class I, II or III-A liquids are not exempt (14.5.2.9(B) NMAC, modifying IRC R105.2(3)).
- Who decides
- Your local building department or CID enforces the state permit rule.
- Good to know
- New Mexico uses a two-part test: the wall must retain less than 3 ft of soil and be no more than 6 ft tall, including the footing.
Sources: srca.nm.gov · srca.nm.gov · fema.gov · rld.nm.gov
New YorkOfficial source
- Residential code
- 2025 Residential Code of New York State (2025 Uniform Code), eff. Dec 31, 2025, with a transition period allowing the 2020 code. Based on the 2024 IRC, according to FEMA.
- Code agency
- NY Department of State – Division of Building Standards and Codes
- Retaining wall exemption
- Not on the statewide exemption list. 19 NYCRR 1203.3's list of work exempt from building permits (small sheds, awnings, partitions, finish work, etc.) doesn't include retaining walls; local enforcement programs decide.
- Who decides
- Your city, town or village code enforcement office decides.
- Good to know
- Retaining walls aren't on the state's list of work that local programs may exempt from permits. Ask your city, town or village code enforcement office.
Sources: law.cornell.edu · dos.ny.gov · fema.gov · dos.ny.gov · dos.ny.gov
North CarolinaSecondary source
- Residential code
- 2018 NC Residential Code (2015 IRC basis) remains in effect. The 2024 NC Residential Code (2021 IRC basis) was adopted, but its effective date is delayed by legislation (according to FEMA, June 2025).
- Code agency
- NC Building Code Council (staffed by the NC Office of State Fire Marshal)
- Retaining wall exemption
- Set by your county or city inspections department. State law (G.S. 160D-1110(c)) waives permits for work of $40,000 or less in a single-family home unless it involves load-bearing structures or certain other work; it doesn't address retaining walls specifically.
- Who decides
- Your county or city inspections department decides.
- Good to know
- The 2024 NC Residential Code was adopted, but its start date was delayed by legislation. Check with your county or city inspections department before you build a wall.
Sources: ncleg.gov · fema.gov · ncosfm.gov
North DakotaSecondary source
- Residential code
- 2024 IRC in the North Dakota State Building Code, eff. Jan 1, 2026. Local enforcement is optional, but jurisdictions that enforce must use the state code and may amend it.
- Code agency
- ND Department of Commerce – Division of Community Services (Building Codes)
- Retaining wall exemption
- Set locally (optional local enforcement; local amendments allowed)
- Who decides
- Your city, county or township decides, and only if it has chosen to enforce a building code.
- Good to know
- North Dakota's 2024 code took effect Jan. 1, 2026. It is enforced only where a city, county or township has chosen to enforce a building code.
Sources: commerce.nd.gov · ndlegis.gov · fema.gov
OhioOfficial source
- Residential code
- Residential Code of Ohio (based on 2018 IRC, first printing); OAC 4101:8, Chapter 1 rule eff. July 1, 2019
- Code agency
- Ohio Board of Building Standards
- Retaining wall exemption
- Exempt if not over 4 ft (1219 mm) measured from the bottom of the footing to the top of the wall, unless supporting a surcharge (RCO §102.10, Building item 3).
- Who decides
- Only certified local residential building departments enforce the RCO. According to FEMA, where there is none, compliance is still the builder's responsibility.
- Good to know
- Height is measured from the bottom of the footing to the top of the wall. Where there's no certified local building department, the builder is still responsible for meeting the code.
Sources: law.cornell.edu · codes.ohio.gov · fema.gov · com.ohio.gov
OklahomaSecondary source
- Residential code
- 2024 IRC as the statewide minimum code (OAC 748:20-6), eff. Sept 14, 2026; previously the 2018 IRC
- Code agency
- Oklahoma Uniform Building Code Commission (OUBCC)
- Retaining wall exemption
- IRC R105.2 as adopted: exempt if not over 4 ft from bottom of footing to top of wall, unless surcharged or impounding Class I, II or IIIA liquids. The state adopts the code's permit chapter only where it doesn't conflict with state law or local enforcement authority.
- Who decides
- Your city or county building department enforces the code and decides.
- Good to know
- Oklahoma's 2024 code took effect Sept. 14, 2026, replacing the 2018 edition. Height is measured from the bottom of the footing to the top of the wall.
Sources: oklahoma.gov · fema.gov · oklahoma.gov
OregonOfficial source
- Residential code
- 2026 Oregon Residential Specialty Code (2024 IRC basis), eff. Oct 1, 2026 (Chapter 1 adopted by OAR 918-480-0005)
- Code agency
- Oregon Building Codes Division (DCBS)
- Retaining wall exemption
- No fixed statewide height. Statewide, a permit is required for retaining walls that provide safeguards for building users, support a regulated building, or retain material that could impact a regulated building if not restrained. Cities and counties may require permits for other walls by ordinance, but not for walls 4 ft or less (bottom of footing to top of wall) unless they support an ascending slope steeper than 3:1 or a nonsoil surcharge; a higher local threshold is allowed (2026 ORSC R101.2.2 item 2).
- Engineer required
- ORSC R404.4: walls not braced at the top that retain more than 48 in. of unbalanced fill, or walls over 24 in. that resist other lateral loads, must be designed to accepted engineering practice with a 1.5 safety factor against sliding and overturning.
- Who decides
- Your city or county building department (or the state BCD where it serves as building official) decides.
- Good to know
- Oregon's 2026 code took effect Oct. 1, 2026. Whether you need a permit depends on what the wall supports or protects, not just its height.
Sources: law.cornell.edu · scappoose.gov · fema.gov · oregon.gov · oregon.gov
PennsylvaniaOfficial source
- Residential code
- 2021 IRC with PA modifications under the Uniform Construction Code, eff. Jan 1, 2026 (L&I Triennial Update, Reg. #12-125 / IRRC #3455: approved Oct 16, 2025, published in the Pa. Bulletin Nov 8, 2025). It replaced the 2018 IRC adoption that took effect Feb 14, 2022.
- Code agency
- PA Department of Labor & Industry (Uniform Construction Code)
- Retaining wall exemption
- Exempt if not over 4 ft measured from the lowest level of grade to the top of the wall, unless the wall supports a surcharge (34 Pa. Code §403.62(c)(2)).
- Who decides
- Your municipality or its UCC code official decides. Local ordinances can be stricter, subject to appeal to L&I.
- Good to know
- Pennsylvania measures height from the lowest level of grade, not the bottom of the footing. Your municipality's rules can be stricter than the state's.
Sources: law.cornell.edu · law.cornell.edu · fema.gov · pa.gov · irrc.state.pa.us · irrc.state.pa.us
Rhode IslandOfficial source
- Residential code
- RISBC-2 Rhode Island State One and Two Family Dwelling Code (2021 IRC with RI amendments, 510-RICR-00-00-2); current version eff. Dec 1, 2025
- Code agency
- Rhode Island Building Code Commission (State Building Office)
- Retaining wall exemption
- Exempt if not over 32 in high measured from the lower finished grade to the top of the wall, unless supporting a surcharge. Any cast-in-place concrete retaining wall over 24 in requires a permit (RISBC-2 R105.2 item 3, 510-RICR-00-00-2).
- Who decides
- Your city or town building official enforces the state code.
- Good to know
- Rhode Island has one of the strictest limits: walls over 32 in. need a permit, and poured concrete walls over 24 in. do too.
Sources: newshorehamri.gov · fema.gov · ribcc.ri.gov · rules.sos.ri.gov · regulations.justia.com
South CarolinaOfficial source
- Residential code
- 2021 IRC with SC modifications, eff. Jan 1, 2023. The 2024 SC Building Codes take effect Jan 1, 2027.
- Code agency
- South Carolina Building Codes Council (LLR)
- Retaining wall exemption
- Exempt if not over 4 ft from bottom of footing to top of wall, unless supporting a surcharge or impounding Class I, II or IIIA liquids (2021 IRC R105.2 as adopted; the Council's 2021 modification index has no Chapter 1 changes).
- Who decides
- Your county or municipal building department enforces the state code.
- Good to know
- South Carolina's 2024 building codes take effect Jan. 1, 2027, so confirm the wall rule with your building department after that date.
Sources: llr.sc.gov · llr.sc.gov · llr.sc.gov · fema.gov
South DakotaSecondary source
- Residential code
- No statewide residential code. According to FEMA, jurisdictions that adopt one must use the 2021 IRC.
- Code agency
- None for residential construction
- Retaining wall exemption
- Set locally
- Who decides
- Your city or county decides, if it has adopted a residential code.
Sources: fema.gov
TennesseeSecondary source
- Residential code
- 2018 IRC with Tennessee amendments (Rule 0780-02-23-.02), eff. July 16, 2020, adopted by the State Fire Marshal. According to FEMA, jurisdictions may opt out if they enforce a code no more than 7 years older than the latest edition.
- Code agency
- Tennessee State Fire Marshal's Office (Department of Commerce & Insurance) – Codes Enforcement
- Retaining wall exemption
- Set locally. The state's residential program requires state permits only for new one- and two-family dwellings and townhouses and for additions of 30 sq ft or more of interior space (Rule 0780-02-23-.05); retaining walls aren't covered. Cities and counties that enforce their own codes decide.
- Who decides
- Your city or county building department decides (in opt-out jurisdictions, under its own code).
- Good to know
- The state's permit program covers only new homes and additions of 30 sq ft or more of interior space, not retaining walls. Cities and counties that enforce their own codes decide.
Sources: tn.gov · fema.gov · tn.gov · regulations.justia.com · regulations.justia.com
TexasSecondary source
- Residential code
- No code for the whole state. According to FEMA, the 2012 IRC is the residential code for municipalities, which may amend it broadly.
- Code agency
- None (set by statute; no state residential code agency)
- Retaining wall exemption
- Set locally
- Who decides
- Your city decides inside city limits.
- Good to know
- What applies outside city limits isn't confirmed, so check locally before you build.
Sources: fema.gov
UtahOfficial source
- Residential code
- 2021 IRC with Utah amendments (Utah Code Title 15A). HB 65 (2026) keeps the 2021 IRC while moving other codes to 2024.
- Code agency
- Utah Uniform Building Code Commission / Division of Professional Licensing
- Retaining wall exemption
- Exempt if retaining less than 4 ft (1219 mm) of unbalanced fill, unless supporting a surcharge or requiring design per IRC R404.4 (HB 65 (2026) replacement of R105.2 item 3 in §15A-3-202, eff. July 1, 2026).
- Engineer required
- Walls that require design under IRC R404.4 are not exempt from permit (HB 65 text).
- Who decides
- Your city or county building department decides under the state code.
- Good to know
- Since July 1, 2026, Utah measures wall height by the unbalanced fill it holds back, not from the footing. Walls that require design under IRC R404.4 still need a permit.
Sources: le.utah.gov · le.utah.gov · fema.gov · commerce.utah.gov · kutv.com
VermontSecondary source
- Residential code
- No statewide residential code (local adoption)
- Code agency
- None for one- and two-family homes (the Division of Fire Safety enforces the state codes it adopts)
- Retaining wall exemption
- Set locally
- Who decides
- Your town decides, if it has adopted a residential code. A rental home counts as a 'public building' under the state Division of Fire Safety, so check with DFS for a rental property.
- Good to know
- The state Division of Fire Safety doesn't regulate an owner-occupied single-family home, but it does cover rentals. For a rental property, check with the Division.
Sources: fema.gov · awc.org · legislature.vermont.gov · firesafety.vermont.gov
VirginiaOfficial source
- Residential code
- 2021 Virginia Uniform Statewide Building Code (2021 IRC basis), eff. Jan 18, 2024
- Code agency
- Virginia Department of Housing and Community Development (Board of Housing and Community Development)
- Retaining wall exemption
- Exempt if supporting less than 3 ft of unbalanced fill and not built to impound Class I, II or III-A liquids or to support a surcharge other than ordinary unbalanced fill (USBC §108.2, item 7; 13VAC5-63-80).
- Who decides
- Your county or city building department enforces the USBC.
- Good to know
- Virginia is stricter than the model code: the limit is 3 ft of unbalanced fill, not 4 ft measured from the footing.
Sources: law.lis.virginia.gov · fema.gov · dhcd.virginia.gov
WashingtonSecondary source
- Residential code
- 2021 IRC with WA amendments (State Building Code), eff. Mar 15, 2024. The 2024 IRC is targeted for adoption Oct 16, 2026, effective May 3, 2027.
- Code agency
- Washington State Building Code Council (SBCC)
- Retaining wall exemption
- Exempt if not over 4 ft from bottom of footing to top of wall, unless supporting a surcharge or impounding Class I, II or IIIA liquids (2021 IRC R105.2; WA's 2021 IRC amendment insert pages contain no R105.2 change).
- Who decides
- Your city or county building department decides and may adopt local amendments.
- Good to know
- Washington's 2024 codes take effect May 3, 2027. Cities and counties may adopt local amendments, so check with your building department.
Sources: sbcc.wa.gov · sbcc.wa.gov · sbcc.wa.gov · tukwilawa.gov · fema.gov
West VirginiaSecondary source
- Residential code
- 2018 IRC in the WV State Building Code (87CSR4). It applies only where a city or county adopts the State Building Code.
- Code agency
- West Virginia State Fire Commission / State Fire Marshal
- Retaining wall exemption
- Exempt if not over 4 ft from bottom of footing to top of wall, unless supporting a surcharge or impounding Class I, II or IIIA liquids (2018 IRC R105.2 as adopted; 87CSR4 amendments don't touch Chapter 1), in jurisdictions that adopt the code.
- Who decides
- Only cities and counties that have adopted the State Building Code issue permits; your local building department decides.
- Good to know
- The state code applies only where your city or county has adopted it, so check with your local building department.
Sources: law.cornell.edu · law.cornell.edu · fema.gov · firemarshal.wv.gov · firemarshal.wv.gov · firemarshal.wv.gov
WisconsinSecondary source
- Residential code
- Uniform Dwelling Code (Wis. Admin. Code SPS 320–325), Wisconsin's own code, not the IRC (according to FEMA)
- Code agency
- Wisconsin Department of Safety and Professional Services (DSPS)
- Retaining wall exemption
- Set locally. The Uniform Dwelling Code covers new one- and two-family dwellings and doesn't regulate retaining walls; municipalities may regulate structures outside its scope (detached buildings, fences, driveways and the like) by local ordinance (SPS 320.02(2)(c), per DSPS's UDC commentary).
- Who decides
- Your city, village, town or county decides under its own ordinances.
- Good to know
- Wisconsin's Uniform Dwelling Code doesn't cover retaining walls, but your city, village, town or county may regulate them by local ordinance.
Sources: fema.gov · dsps.wi.gov · Dsps.Wi.Gov
WyomingSecondary source
- Residential code
- No statewide residential code (local adoption)
- Code agency
- None for residential construction
- Retaining wall exemption
- Set locally
- Who decides
- Your city or county decides, if it has adopted a residential code.
- Good to know
- Some Wyoming cities and counties have adopted the IRC, but it isn't a statewide standard.
Sources: fema.gov
Before you build any wall
Permit or not, a wall still has to stand up. Most wall failures come from water and poor compaction, not from the block. Plan the base, drainage stone and outlets first; our guides to retaining wall drainage, base depth and segmental wall systems cover the details, and the retaining wall block calculator sizes the order.
Frequently Asked Questions
How tall can a retaining wall be without a permit?
Under the model International Residential Code, 4 feet measured from the bottom of the footing to the top of the wall, as long as it doesn’t support a surcharge. Many states and towns follow that, but some measure differently or set a lower limit. Check your state above and your local building department.
Do I need an engineer for a retaining wall?
Usually once a wall is over the permit height or supports a surcharge like a driveway or slope. Wall block manufacturers also call for an engineered design above certain heights, especially with geogrid.
Does a terraced wall count as one wall or two?
It depends on the spacing. Walls stacked close together act like one taller wall, and building departments may treat them that way. Ask before you build terraces.
What happens if I build a retaining wall without a permit?
If one was required, the town can order you to stop, get a permit after the fact, open it up for inspection or remove it. It can also come up when you sell the house.
More state guides: Frost line depth · 811 dig laws · Contractor licensing · Contractor deposit limits · Building codes · Planting zones · Mechanics lien deadlines · Workers’ comp · Frost dates · Drainage laws · All state guides · Free calculators
Last checked October 31, 2026 against official state and local sources for all 51 entries. Rules change; your state agency or local building department has the final word. Spot something out of date? Email info@muthlerlandscaping.com and we’ll fix it.
Groundwork Design Co. · designed by builders
Get it drawn right before anyone digs
Groundwork Design Co. draws your patio, wall or walkway to scale, with the layout, sizes and materials any local contractor can price. Single-space plans start at $349; Full Yard plans add a grading and drainage concept.
See design plansSee sample plans
In central PA? We design and build engineered and gravity retaining walls in Lock Haven, Williamsport and State College. Talk to our crew.
Using this guide? Link to it or cite it. It’s free to use with a link back, and we keep it updated against official sources.
Cite as: Muthler Landscaping & Construction, “Do You Need a Permit for a Retaining Wall? Rules in All 50 States,” https://muthlerlandscaping.com/state-guides/retaining-wall-permits/ (last checked November 1, 2026).
Get an email when your state’s rules change
We re-check every entry against official sources. Tell us your state and we’ll email you when something changes.