A joist hanger is a small piece of steel doing a big job: it carries the end of a joist to a ledger or beam. The American Wood Council’s DCA 6 guide sets a minimum hanger depth and a minimum vertical load rating by joist size, and it separates hangers from the lighter clips used for uplift and sideways restraint. Here is what the guide says, and what it leaves to the hanger maker.

Quick answer

In the AWC guide (2015 edition, p. 9), a hanger must be at least 60 percent as deep as the ledger or beam, and its vertical capacity must be at least 400 lb for a 2×6 joist, 500 lb for a 2×8, 600 lb for a 2×10 and 700 lb for a 2×12. Mechanical clips used as the second option need at least 100 lb in both uplift and lateral directions. Checked Nov. 23, 2026.

Hanger rules by section

ItemWhat the source statesSource and edition
Hanger depthAt least 60 percent of the depth of the ledger or beam.AWC DCA 6, 2015 edition, p. 9
Vertical capacity, 2×6400 lb minimum.AWC DCA 6, 2015 edition, p. 9
Vertical capacity, 2×8500 lb minimum.AWC DCA 6, 2015 edition, p. 9
Vertical capacity, 2×10600 lb minimum.AWC DCA 6, 2015 edition, p. 9
Vertical capacity, 2×12700 lb minimum.AWC DCA 6, 2015 edition, p. 9
Clips (option 2)Mechanical fasteners or clips with at least 100 lb capacity in both uplift and lateral directions.AWC DCA 6, 2015 edition, p. 9
Beam depth with hangersThe beam must be at least as deep as the joist when joists hang from its side.AWC DCA 6, 2015 edition, p. 6, footnote 4
Opposite sidesJoists must not frame into opposite sides of the same beam.AWC DCA 6, 2015 edition, pp. 5-7
Rim joistA continuous rim joist attaches to the ends of the joists (Figure 11).AWC DCA 6, 2015 edition, p. 11
Metal typeHot-dip galvanized, stainless steel, silicon bronze or copper where touching preservative-treated wood.AWC DCA 6, 2015 edition, p. 2

Check the table label and figures in the AWC PDF before you quote them on a permit drawing.

Trimmer joist hangers (commentary)

The guide’s commentary includes a table of hanger vertical capacity for trimmer joists, the doubled or tripled joists that frame around a stair opening or a header. It is labeled Table C7c, near the page footer C14. The values by joist span are below. The commentary also says trimmer joist span limits depend on whether the hanger attaches through the ledger to the rim board or band joist; without that attachment, Table C7b limits the span.

Joist spanTrimmer joist hanger vertical capacity
8 ft660 lb
10 ft860 lb
12 ft1,060 lb
14 ft1,260 lb
16 ft1,325 lb
18 ft1,430 lb

Commentary values are explanatory, not the prescriptive text. Use them to understand why a trimmer hanger is heavier than an ordinary one, and rely on the guide’s figures and your code office for the build.

Hangers, clips and what each one does

Hanger: carries the load down

The hanger supports the joist end vertically. The guide’s capacity table sets a floor by joist size: heavier joists need hangers with a higher rating.

Clip: holds the joist in place

The second option in the guide uses mechanical fasteners or clips with at least 100 lb in both uplift and lateral directions, to keep the joist from lifting off or sliding sideways.

Depth: keeps the joist seated

The guide’s 60 percent rule keeps the hanger tall enough to hold the joist end against the ledger or beam.

Practical notes from the field

Read the hanger’s rated load before you buy it. A hanger rated for a 2×8 does not qualify under the guide for a 2×12, and the rated load printed in the manufacturer’s data is what you compare with the guide’s minimum. If a hanger has no published allowable load for the fasteners you are using, it does not meet the rule.

Use the fasteners the hanger calls for, in every hole it asks for. A hanger’s rating depends on the nail or screw type and count in its instructions. Substituting a common nail or leaving holes empty can drop the capacity below the guide’s minimum, even if the hanger itself is rated high enough.

Match the hanger metal to the lumber. Treated lumber corrodes plain steel, and the guide’s metal rule applies to hangers as much as to bolts and lags. Mixing a galvanized hanger with the wrong galvanized nail, or a plain zinc-plated hanger with treated lumber, is a failure that shows up years later.

Choose the joist connection with the beam in mind. If the joists hang from the side of the beam, the beam must be at least as deep as the joist. See our beam sizing page for the span tables.

Edition caution, not engineering or legal advice. The numbers on this page come from AWC DCA 6, 2015 edition, which tracks the 2015 IRC. Pennsylvania’s UCC moved to the 2021 IRC effective Jan. 1, 2026, per our IRC rules page, and DCA 6 tables and section numbers can differ between editions. We did not locate a 2021 edition of DCA 6 on awc.org, so confirm hanger requirements with your code office.

Related: joist hanger glossary entry, joist spans and bearing and deck board and fastener rules.

Questions

How deep does a deck joist hanger have to be?

The AWC guide (2015 edition, p. 9) says at least 60 percent of the depth of the ledger or beam.

What load rating must a deck joist hanger have?

The guide sets minimum vertical capacities by joist size: 400 lb for 2×6, 500 lb for 2×8, 600 lb for 2×10 and 700 lb for 2×12.

Do I need clips as well as hangers?

The guide’s second option uses mechanical fasteners or clips with at least 100 lb capacity in both uplift and lateral directions. Check the figure in the guide for which connection applies to your framing.

Can joists hang from both sides of one beam?

No. The AWC guide does not allow joists to frame into opposite sides of the same beam, and a beam that carries hung joists must be at least as deep as the joists.

Sources: American Wood Council, DCA 6 (2015 edition), pp. 2, 5-7, 9, 11 and commentary page C14; our IRC rules page. Checked Nov. 23, 2026.

Muthler Landscaping & Construction · Lock Haven, PA

Planning a deck in central PA?

We build decks and site work across Clinton, Centre, Lycoming and Union counties, and we handle the permits that go with them.

Get a free estimatePennsylvania guide

Muthler Landscaping & Construction LLC · 913 Bellefonte Ave, Lock Haven, PA 17745 · (570) 397-9800 · PA HIC #PA212584.

Using this guide? Link to it or cite it. It’s free to use with a link back, and we keep it updated against official sources.

Cite as: Muthler Landscaping & Construction, “Deck Joist Hangers and Joist-to-Beam Hardware: Capacity and Depth Rules,” https://muthlerlandscaping.com/state-guides/pennsylvania/deck-joist-hanger-requirements/ (page updated November 23, 2026).