34 Pa. Code 403.62 and 403.62a: Residential Permit Exemptions (Fences, Walls, Decks) and the Application
For one- and two-family homes, the Uniform Construction Code (UCC) rules on permits sit in 34 Pa. Code Section 403.62, with the application rules in Section 403.62a. Section 403.62 is where the familiar numbers come from: the fence height, the retaining wall height and the deck height that decide whether a permit is needed. This page walks through both sections, as they appear on Cornell’s Legal Information Institute, checked November 23, 2026. Verify every number against the current regulation. A town that has adopted a stricter ordinance may add requirements, so a state exemption does not always end the conversation with the local code office.
Quick answer
- Fences: no permit if no more than 6 feet high
- Retaining walls: no permit if not over 4 feet tall, measured from the lowest grade to the top of the wall, unless the wall supports a surcharge
- Decks: no permit for uncovered decks whose floor is no more than 30 inches above grade
- Sidewalks and driveways: exempt if 30 inches or less above adjacent grade and not over a basement or story below
- Emergency repairs: go ahead, then apply within 3 business days
When does 403.62(a) require a residential permit?
Subsection (a) says that before starting covered work an owner or authorized agent must apply to the building code official and obtain a permit under 403.62a. Covered work includes constructing, enlarging, altering, repairing, moving or demolishing a residential building, changing its occupancy, and installing, altering, repairing, removing, converting or replacing an electrical, gas, mechanical or plumbing system regulated by the UCC. Subsection (b) lets emergency repair or replacement of equipment proceed without a prior permit, provided an application is submitted to the building code official within 3 business days of the work.
What does the 403.62(c) exemption list say?
Subsection (c) says no permit is required for the exceptions in Section 403.1(b) or the following items, provided the work does not violate any law or ordinance.
| Item | Exempt when |
|---|---|
| (c)(1) Fences | No more than 6 feet high |
| (c)(2) Retaining walls | Not over 4 feet tall from the lowest grade to the top of the wall, unless supporting a surcharge |
| (c)(3) Water tanks on grade | 5,000 gallons or less, with a height-to-diameter or width ratio of 2 to 1 or less |
| (c)(4) Sidewalks and driveways | 30 inches or less above adjacent grade and not placed over a basement or story below |
| (c)(5) Prefabricated pools | Less than 24 inches deep |
| (c)(6) Swings and playground equipment | Accessory to a one- or two-family dwelling |
| (c)(7) Window awnings | Supported by an exterior wall, projecting no more than 54 inches, needing no additional support |
| (c)(8) Decks | Uncovered, with a floor no more than 30 inches above grade |
| (c)(9) Communications wiring | Installing or rearranging |
These are the numbers contractors quote most often. The retaining wall figure is measured from the lowest grade to the top of the wall, and a wall that supports a surcharge, such as a driveway or a sloped bank above it, loses the exemption under the text. For our own wall guidance see the retaining wall permit page, and for decks see the shed permit page and fence law page. Our permit exemptions page gives the plain-language version.
What is not an ordinary repair under 403.62(d)?
Ordinary repairs need no permit, but four kinds of work are not ordinary repairs and so are not exempt: cutting away a load-bearing wall, partition or part of a wall; removing or cutting any structural beam or load-bearing support; removing or changing a required means of egress, or rearranging parts of a structure in a way that affects egress requirements; and adding to or relocating standpipe, water supply, sewer, drainage, drain leader, gas, soil, waste, vent or similar piping, electric wiring or mechanical equipment. Subsection (e) exempts installing, altering or repairing generation, transmission, distribution, metering or related equipment owned and controlled by public service agencies.
What does the residential application under 403.62a require?
Subsection (b) says the applicant submits an application with construction documents (plans and specifications) and all other construction-related permits or approvals required by 403.102(n). Subsection (c) lets the official waive the construction documents if the work does not need review for UCC compliance. Subsection (d) adds items for a building or structure in a National Flood Insurance Program flood hazard area: delineation of flood hazard areas, floodway boundaries and flood zones with the design flood elevation; for Zone AO only, the elevation of the proposed lowest floor and its height above the highest adjacent grade; and design flood elevations from the municipality’s FEMA Flood Insurance Rate Map, or other sources if the map lacks them. Subsection (e) requires a site plan showing the size and location of new construction and existing structures, each structure’s distance from lot lines, and for demolition what will be demolished and what remains. The official may waive or modify the site plan for alterations, repairs or other warranted reasons. See our permit application page.
What owners and contractors can do with these sections
- Measure a retaining wall from the lowest grade, not the nearest grade, and ask whether anything above it adds a surcharge.
- Measure deck height from grade to the floor, and remember the exemption is for uncovered decks only.
- Check whether a driveway or walk sits over a basement or story below, which removes the exemption.
- Ask the municipality whether it has stricter local rules before you start an exempt job.
- If a job involves cutting a load-bearing wall or moving plumbing or wiring, treat it as permit work.
Sources
34 Pa. Code 403.62 (Cornell LII) and 403.62a (Cornell LII). Checked Nov. 23, 2026. Verify against the current regulation, which has been amended.
FAQ
How tall can a retaining wall be without a UCC permit in Pennsylvania?
Section 403.62(c)(2) exempts retaining walls not over 4 feet tall, measured from the lowest grade to the top of the wall, unless the wall supports a surcharge. Check for stricter local rules and verify the current text.
Do I need a permit for a deck that is 30 inches off the ground?
Section 403.62(c)(8) exempts uncovered decks whose floor is no more than 30 inches above grade. Covered decks are not in that exemption under the text.
How high can a fence be without a permit?
Section 403.62(c)(1) exempts fences no more than 6 feet high, provided the work does not violate any law or ordinance.
Can I fix a leak or replace a pipe without a permit?
Ordinary repairs need no permit, but under 403.62(d) adding to or relocating piping, wiring or mechanical equipment is not an ordinary repair. Ask the code office about a specific job.
This is a plain-English summary of what the official sources state, not legal advice. Regulations get amended and agencies and courts interpret them, so talk to a Pennsylvania attorney about your own situation before you rely on any of it.
Related: Pennsylvania guide · Commercial permits, 403.42 · Pennsylvania building code · UCC opt-in vs opt-out.
Using this guide? Link to it or cite it. It’s free to use with a link back, and we keep it updated against official sources.
Cite as: Muthler Landscaping & Construction, “34 Pa. Code 403.62 and 403.62a: Residential Permit Exemptions (Fences, Walls, Decks) and the Application,” https://muthlerlandscaping.com/state-guides/pennsylvania/ucc-34-pa-code-403-62-residential-permit-exemptions-application/ (page updated November 23, 2026).
Get an email when your state’s rules change
We re-check every entry against official sources. Tell us your state and we’ll email you when something changes.