Pennsylvania Construction Code Act Sections 901 to 903: Special Exemptions, Historic and Older Buildings and the $1,000 Penalty
Chapter 9 of Pennsylvania’s Construction Code Act (Act 45 of 1999, 35 P.S. 7210.101 et seq.) collects the special cases. Section 901 lists exemptions and code tweaks, from manufactured housing to log walls and a sprinkler offer for new homes. Section 902 deals with historic structures and buildings that never received an occupancy certificate. Section 903 sets the penalty. Chapter 11 closes the act with savings, repeals and the effective date. This page covers them, from the act as published by the General Assembly. Verify every number against the current statute text. The general penalty discussion is also on our UCC violations and fines page.
Quick answer
- 903(a): a violation is a summary offense with a fine of up to $1,000 plus costs, and each day is a separate violation
- 901(a): manufactured housing with a federal label, and industrialized housing, are outside the act
- 901(g): builders of one- and two-family homes must offer buyers an optional sprinkler system, with cost and benefit information, at or before the purchase contract
- 902(b): buildings built before April 27, 1927 are deemed certified for occupancy purposes
- 1103: most of the act took effect 90 days after the Pennsylvania Bulletin published notice that the required regulations were final
What does Section 901 exempt or adjust?
| Subsection | Topic | What it says |
|---|---|---|
| 901(a) | Housing types | Act does not cover manufactured housing bearing a federal construction-standards label, or industrialized housing |
| 901(b) | Religious sect exemption | Dwelling or one-room schoolhouse of a recognized sect may be exempted from electrical, non-pressure-treated wood or plumbing provisions that conflict with sect tenets |
| 901(c) | Natural cut trees | One IFC (2003) section excluded; municipalities may restrict tree placement by ordinance |
| 901(d) | Coal-fired boilers | Residential coal-fired boilers follow an IRC (2003) section but are exempt from its stamping requirement |
| 901(e) | Pole barns | Agricultural-use pole barns on fairgrounds exempt, except for ICC Electrical Code inspections |
| 901(f) | Log walls | Walls averaging at least 5 inches thick allowed in residences if fenestration U-factor is 0.31 or less and heating equipment meets listed efficiency ratings |
| 901(g) | Fire sprinklers | IRC (2009) R313.2 excluded; builders must offer an optional system to buyers |
| 901(h) | Floor fire protection | Unrequired floor assemblies need a 1/2-inch gypsum or 5/8-inch wood structural panel membrane, with exceptions |
| 901(i) | Wall bracing | IRC (2009) R602.10 through R602.12.1.6 excluded; IRC (2006) R602.10 through R602.11.3 remain |
| 901(j) | Refrigerants | Federally authorized refrigerants allowed under conditions; expires when the regulation adopting the 2024 model code review takes effect |
The items builders run into: sprinklers, floors, log walls
Subsection (g) removes the model code’s residential sprinkler requirement for new one- and two-family homes but replaces it with a disclosure duty. At or before the purchase contract, the builder must offer the buyer an optional sprinkler system and provide cost information and benefit information. Put the written offer and the buyer’s answer in the contract file. Whether a missed offer creates liability or a remedy is a legal question for an attorney, since the act does not state a penalty beyond Section 903.
Subsection (h) sets the floor assembly rule: unrequired floor assemblies need a membrane of 1/2-inch gypsum or 5/8-inch wood structural panel, subject to exceptions. Two exceptions are unprotected areas up to 80 square feet per story and floors using 2×10 nominal dimension lumber or larger. Subsection (f) allows log walls averaging at least 5 inches thick in residences when fenestration has a U-factor of 0.31 or less and heating equipment meets listed ratings, such as 90 percent AFUE for gas furnaces, 85 percent AFUE for oil furnaces and boilers, and 8.2 HSPF for air-source heat pumps. Check the current list before specifying equipment.
The religious sect exemption in 901(b)
Applicants for a dwelling or one-room schoolhouse used by members of a recognized religious sect may be exempted from electrical, non-pressure-treated lumber or wood, or plumbing provisions that conflict with sect tenets. A code administrator must grant a compliant application. If the property is later sold or leased, it must be brought into compliance unless the new owner files a qualifying affidavit. This is a niche rule with sale consequences, so sellers, buyers and lenders should have an attorney read the affidavit requirements before closing.
Historic and older buildings: Section 902
- 902(a) Historic sites: the 1999 BOCA code’s construction provisions do not apply to qualifying historic structures, or to non-residential new structures on historic sites, if the code official judges them safe.
- 902(b) Department jurisdiction: the Department issues certificates of occupancy for uncertified buildings unless a building is unsafe. Egress, fire and accessibility requirements vary by construction date. Automatic sprinklers are required for E, H, I, R-1 and R-2 use groups and for buildings with occupied floors more than 75 feet above fire department access. Buildings constructed before May 19, 1984 have no sprinkler requirement; those built after May 18, 1984 must complete installation within five years of the effective date. Buildings built before April 27, 1927 are deemed certified. Owners may keep current occupancy while making reasonable compliance efforts.
- 902(c) Municipal officials: they issue certificates for uncertified buildings meeting subsection (b) or the latest IEBC, and may deny certificates for unsafe conditions.
- 902(d): renovations, additions, alterations or occupancy changes still trigger Chapter 3.
An “uncertified building” is an existing building not approved for use and occupancy before April 9, 2004, with residential buildings excluded; see our Section 103 definitions page. A buyer of an older commercial building should ask for its certificate history before closing, because a missing certificate can lead to a Section 902 process.
What penalty does Section 903 set?
Under Section 903(a), a violation is a summary offense carrying a fine of up to $1,000 plus costs. Each day of a continuing violation counts as a separate violation. Under 903(b), penalty proceeds go to the entity with enforcement jurisdiction. These figures match the amounts on our existing fines page. Daily counting is what makes a long unpermitted job costly, since a violation that runs for weeks can be charged day by day. A citation is a legal matter; talk to a Pennsylvania attorney before you respond.
Chapter 11: savings, repeals and the effective date
Section 1101 says the act does not repeal or affect specified sections of the Fire and Panic Act, Section 2203-A of the Administrative Code of 1929, the Boiler Regulation Law and several other laws, including the Liquefied Petroleum Gas Act, the Human Relations Act, the Flood Plain Management Act, the Health Care Facilities Act and the Older Adult Daily Living Centers Licensing Act. County health-rule construction standards adopted after October 31, 1996 must comply with Chapters 3 and 5. Section 1102 repeals specified Fire and Panic Act sections, the Elevator Regulation Law of 1929, a 1965 accessibility act, a 1976 permit-approval act, the Building Energy Conservation Act of 1980, a 1990 restroom act and the Dry Cleaning Law of 1990, and repeals all other conflicting laws to the extent of the conflict. Section 1103 made 104(d)(3) and (4), 301, 302, 701 and 1103 effective immediately, and the rest 90 days after the Pennsylvania Bulletin published notice that the required regulations were final. The savings list is why flood plain rules and fire and boiler laws still apply alongside the UCC.
Sources
Construction Code Act, Act 45 of 1999, Sections 901 through 903 and 1101 through 1103, text published by the Pennsylvania General Assembly (PDF). Checked Nov. 23, 2026. Verify against the current statute text.
FAQ
What is the maximum fine under the Pennsylvania Construction Code Act?
Section 903(a) makes a violation a summary offense with a fine of up to $1,000 plus costs, and each day a violation continues is a separate violation.
Must a builder offer fire sprinklers for a new house?
Section 901(g) excludes the model code sprinkler requirement for one- and two-family homes but requires builders to offer an optional system, with cost and benefit information, at or before the purchase contract.
Is manufactured housing covered by the act?
Section 901(a) says the act does not cover manufactured housing bearing a federal construction-standards label, or industrialized housing.
Does an old building need a certificate of occupancy?
Section 902(b) deems buildings built before April 27, 1927 certified, and sets a process for other uncertified buildings. Ask an attorney or the Department about a specific building.
This is a plain-English summary of what the official sources state, not legal advice. Statutes get amended and courts interpret them, so talk to a Pennsylvania attorney about your own situation before you rely on any of it.
Related: Pennsylvania guide · UCC violations and fines · Certificate of occupancy · Pennsylvania building code.
Using this guide? Link to it or cite it. It’s free to use with a link back, and we keep it updated against official sources.
Cite as: Muthler Landscaping & Construction, “Pennsylvania Construction Code Act Sections 901 to 903: Special Exemptions, Historic and Older Buildings and the $1,000 Penalty,” https://muthlerlandscaping.com/state-guides/pennsylvania/construction-code-act-sections-901-903-exemptions-penalties/ (page updated November 23, 2026).