Guides · Deck code rules · Beams and posts
Deck post-to-beam connections: IRC R507.5 and the AWC guide
The post-to-beam joint carries the deck’s weight down to the footing. The model code and the AWC deck guide are specific about how that joint is made, and about the common shortcut they do not allow.
The AWC DCA 6 guide shows two connections: a notched post (Fig. 8A) or a post cap (Fig. 8B). Three-ply beams need a post cap, and fastening a beam to the side of an un-notched post is prohibited (Fig. 9) (p. 10). The model IRC says the connection must transfer vertical load and resist horizontal displacement, with bolts and washers (R507.5.2).
Connection rules by section
| Point | What the source states | Section |
|---|---|---|
| Beam spans | Beam spans come from the beam span table. | IRC R507.5, Table R507.5 |
| Bearing | A multi-ply beam has full bearing on the post. | IRC R507.5.1 |
| Connection | Must transfer vertical load and resist horizontal displacement; bolts with washers. | IRC R507.5.2 |
| Two options | Notched post (Fig. 8A) or post cap (Fig. 8B). | AWC DCA 6, p. 10 |
| Three-ply beams | Need a post cap. | AWC DCA 6, p. 10 |
| Not allowed | Attaching the beam to the side of the post without notching (Fig. 9). | AWC DCA 6, p. 10 |
| Corner bracing | Corner posts over 2′-0″ high need diagonal bracing with 1/2 inch lag screws. | AWC DCA 6, p. 10 |
| Lateral hold-downs | Two hold-downs of at least 1,500 lb within 24 inches of each end, or four of at least 750 lb. | IRC R507.9.2, Figs. R507.9.2(1) and (2) |
Our sources disagree on the nailing pattern for built-up beams (one gives two rows at 19 inches on center, another 16 inches), so we leave the number out. Check your code edition. Glossary: beam and post base. Related: joist spans and bearing and footing requirements.
Questions
Can I bolt a deck beam to the side of a post?
The AWC guide prohibits attaching the beam to the side of a post without notching it (Fig. 9, p. 10). Use a notched post or a post cap.
Does a three-ply beam need a post cap?
Yes, per the AWC guide (p. 10).
Does a deck need lateral hold-downs?
The model IRC calls for two 1,500 lb hold-downs near each end, or four 750 lb hold-downs (R507.9.2).