Septic system setback distances by state

How far a septic tank and drain field must sit from a well, a building, a property line and water, in feet. We list the state rule for the 48 of 51 jurisdictions we have confirmed from official pages; the rest are marked Not confirmed. Wells have their own page: see well setbacks by state.

Read this first

These are state minimums. Your county or town health department issues the permit and can require more. 48 of 51 jurisdictions are confirmed against the rule text so far; the rest say “Not confirmed” until we verify them. Last checked November 23, 2026. Not legal or engineering advice.

Septic setbacks, state by state

Each cell reads: well / building / property line / water, in feet. An asterisk (*) means the number depends on a condition in the notes. “None set” means the rule gives no statewide distance. The tank column also covers the pump or dosing tank where the rule does.

StateSeptic tank
well / building / lot line / water
Drain field
well / building / lot line / water
Rule and notes
AlabamaNot confirmed – check your local code. Statewide distances are set in Table 4 of the Alabama Department of Public Health onsite sewage rules (Ala. Admin. Code ch. 420-3-1), which was not available as text for us to check. Rule: Ala. Admin. Code r. 420-3-1-T4, Table 4.
Alaska100 / none set / none set / 100100 / none set / none set / 10018 AAC 72.100(a)(1); 18 AAC 72.520(b). Tank and field 100 ft from a private water system source, measured nearest edge to nearest edge. Public water system sources: 200 ft from a wastewater disposal system (18 AAC 80.020, Table A). Surface water is measured from the mean annual high water level of a lake, river, stream, spring or slough, or the mean higher high water level of tidal coastal waters. The state rules set no distance to buildings or lot lines. The field must be 50 ft from a slope steeper than 25 percent with more than a 10 ft drop, and the tank 5 ft from the field. DEC may require greater distances or approve lesser ones by waiver. Systems are installed under DEC rules by DEC-certified installers, registered engineers or DEC-approved homeowners; Anchorage and Valdez have additional local requirements.
Arizona100 / 10 / 5-50* / 100100 / 10 / 5-50* / 100A.A.C. R18-9-A312(C). One set of distances covers the whole system, including the septic tank, disposal works and reserve area (amended effective June 19, 2023). Lot line: 50 ft from a line shared with a lot not served by a common drinking water system or an existing water well, reducible to 5 ft if the owners of affected undeveloped neighboring lots record an agreement to keep any new well at least 100 ft from the treatment and disposal works and ADEQ approves; 5 ft from all other lot lines. Public and private wells are both 100 ft. Buildings include porches, decks and steps. Streams, lakes, reservoirs and canals are measured from the high water line of a 10-year, 24-hour rainfall event (canals from the edge); a surface drinking water intake is 200 ft. ADEQ may approve reduced setbacks for some systems or require larger ones. ADEQ issues permits through delegated county environmental and health departments.
Arkansas100 / 10 / 10 / 100*100 / 10 / 10 / 100*ADH Onsite Wastewater Rules, Sec. 6.2. One list covers all collection, treatment and renovation facilities, so tanks and fields share the same distances. Streams and lakes are measured from the high-water mark; ponds are 50 ft on the same property and 100 ft on adjacent property in the pond watershed. 300 ft from the high-water mark when within a quarter mile of a public water supply intake on that water, and 300 ft from springs used as a public water supply. ADH or its authorized agent issues the construction permit.
Californiaset by your local agency / set by your local agency / set by your local agency / set by your local agencyset by your local agency / set by your local agency / set by your local agency / set by your local agencyOWTS Policy (amended 2023), Secs. 7.5 and 9.4.10. The State Water Board OWTS Policy leaves these distances to local agencies. Most counties have an approved Local Agency Management Program (LAMP), which sets its own setbacks in place of the statewide Tier 1 rules. No LAMP may allow a new dispersal system closer than 150 ft to a public water well (200 ft if the system is deeper than 10 ft), or within 200 to 400 ft of the high water mark of a water body near a public drinking water intake; replacement systems and some existing lots may go closer with added treatment. Where no LAMP is approved, Tier 1 sets, for the tank and dispersal system alike, 5 ft to lot lines and structures, 100 ft to water wells, 100 ft to springs and streams (from the bank) and 200 ft to lakes, ponds and wetlands (from the high water mark). Counties, cities or special districts issue permits, overseen by the Regional Water Boards.
Colorado50 / 5 / 10* / 50100* / 20* / 10* / 50*5 CCR 1002-43.7, Table 7-1. Regulation 43, current version effective June 15, 2025. Field 20 ft from a structure with a basement, crawl space or footing drains, 10 ft from one without. Field distances to wells and surface water grow 8 ft for each 100 gallons per day of design flow between 1,000 and 2,000 gallons per day. Wells include springs and underground potable water cisterns; the table sets no separate public well distance, and well variances cannot go below 75 ft for new construction. Water includes lakes, streams, water courses, open irrigation channels and wetlands; the rule does not say where it is measured from. The local agency may cut the 10 ft lot line setback to as little as 3 ft with a surveyed line, requested at permit time. Local boards of health may require greater distances. Local public health agencies issue permits for systems up to 2,000 gallons per day.
Connecticut75* / 10 / 10 / 50*75* / 10 / 15* / 50*Public Health Code 19-13-B103 and DPH Technical Standards (effective Sept. 1, 2026), Sec. 5.1 Table 1. Well distance is 75, 150 or 200 ft depending on well yield; fast soils double distances. Field to property line is 15 ft up or side-gradient, 25 ft down-gradient (10 if reduced). Watercourse 50 ft (25 ft for lots that predate Aug. 16, 1982 and are not in a public water supply watershed). Your local director of health permits.
Delaware50 / 10 / 10 / 25100* / 10 / 10 / 100*7 Del. Admin. Code 7101, Exhibit C (PDF). Field to well can drop to 50 ft with approvals. Field to watercourse can drop to 50 ft if it is not a public supply or shellfish water. No setback from an ephemeral watercourse. Public and industrial wells: 150 ft. DNREC permits.
District of ColumbiaNone set (the rule gives no numeric distances)21 DCMR 901-905; D.C. Code 6-503. Septic is allowed only where public sewer is not reasonably available, as certified by the Director.
Florida75 / 5 / 5 / 7575 / 5 / 5 / 75Fla. Admin. Code R. 62-6.005 (formerly 64E-6.005), amended 6-8-26. Well distance is for a private potable well; a public drinking water well is 100 ft (flow up to 2,000 gpd) or 200 ft, and a non-potable well is 50 ft. Pre-1972 platted lots: at least 50 ft to surface water. 15 ft from the design high-water line of swales and retention areas. Some exceptions apply under s. 381.0065(4)(i), F.S. County health departments permit, except in the Panhandle counties and Marion County, where DEP permits.
Georgia50 / 10 (recommended) / 10 / 25100 / 10 with basement, 5 without / 5 / 50Ga. Comp. R. 511-3-1-.05(2) and -.07(3). The 10 ft tank-to-house distance is a “should,” not a “shall.” The county board of health issues the permit and may allow lesser or greater distances for tanks.
Hawaiinone set / 5 / 5 / 50none set / 5 / 5* / 50HAR 11-62-32; Appendix D, Table II. The rule sets no distance to private wells. Potable water sources serving public water systems: 500 ft from a treatment unit and 1,000 ft from a soil absorption system or seepage pit. Field lot line distance is 5 ft for a soil absorption system and 9 ft for a seepage pit. Surface water includes streams, ponds, lakes and the ocean at the shoreline certification. Distances are measured from the outer edge of each item, and the director may approve exceptions. New cesspools are not allowed. The Department of Health Wastewater Branch reviews each system before the director signs the county building permit application.
Idaho50* / 5 / 5 / 50*100 / 10* / 5 / 200 to 100*IDAPA 58.01.03.007(18) (tank) and 58.01.03.008(01)(d) and 008(03) (drain field), as amended effective July 1, 2025. Tank to well is 100 ft if the supply is public. Tank to surface water is 50 ft for permanent or intermittent water, 25 ft for temporary. Field to foundation is 10 ft with a crawl space or slab, 20 ft with a basement. Field to permanent or intermittent surface water (not irrigation canals or ditches) is 200 ft in soil group A, 125 ft in B, 100 ft in C; temporary surface water and irrigation canals or ditches 50 ft. Effluent pipes have the same separation distances as the tank unless the DEQ Director approves otherwise. District health departments permit.
Illinois50 / 5 / 5 / 2575 / 10 / 5 / 2577 Ill. Adm. Code 905, Appendix A, Illustration D. Applies to clay, silt and loam soils only; for other soils the Department sets the distances. The local health department or IDPH approves plans.
Indiana50* / 10 / 5 / 2550* / 10 / 5 / 25410 IAC 6-8.3, Sec. 57, Table I (PDF). Well distance doubles to 100 ft for absorption in soils loading above 0.75 gpd/sq ft within 34 inches; public water well 200 ft; ponds and lakes 50 ft. Rule change in progress (LSA #26-64, draft keeps these values): recheck before you build.
Iowa50 / 10 / 10 / 50*100 / 10 / 10 / 100*Iowa Admin. Code 567-60.2(2)”c”, Table I (PDF), applied to private systems by 567-69.1(7). Tank means the “closed portion” (the fully contained part, such as a septic tank or impervious vault toilet); field means the “open portion” (the part that lets effluent into the soil, such as a soil absorption system). Water figure is for a lake or reservoir; a stream or pond is 25 ft for both. Property line distance applies unless a mutual easement is signed and recorded. Public wells: 100 to 400 ft depending on well depth and component. Permits go through your local administrative authority.
Kansas50 / none set / none set / none set50 / none set / none set / none setK.A.R. 28-5-2; K.A.R. 28-30-8(a). The only statewide septic distance is at least 50 ft between a septic tank or lateral field and a water well or spring. The state rules set no distance to buildings, lot lines or surface water: those come from county sanitary codes approved by KDHE before July 1, 1997, or from KDHE Bulletin 4-2 where a county has no such code. A system may not drain into a stream, ditch or onto the ground. Private systems must be approved by KDHE or the appropriate local authority.
Kentucky50 / 10 / 5 / 2570 / 10 / 5 / 25902 KAR 10:085, Sec. 8(1), Table 7. Basements: 20 ft. Lakes: 25 ft tank, 50 ft field. In-ground pool: 10 ft tank, 20 ft field.
Louisiana50 / none set / none set / none set100* / 10 / 10 / none setLAC 51:XIII.719 and 51:XII.327. Well distances come from Part XII (water supplies) of the state sanitary code: tank 50 ft, absorption field 100 ft, which may be reduced to 50 ft for a private well. Trenches 10 ft from dwellings and property lines. No statewide tank-to-building, tank-to-lot-line or water-body distance is set. The state health officer issues permits; installers notify the parish health unit.
Maine50 / 8 / 10 / 100*100* / 20* / 10 / 100*10-144 CMR ch. 241, Sec. 8, Table 8B. Field 100 ft from a private well; when that is impractical, the local plumbing inspector may allow as little as 60 ft for a well with a deep casing or liner seal. Wells using 2,000 gallons a day or more and public water system wells need 300 ft from the field and 150 ft from the tank. Field 20 ft from a full basement, 15 ft from a slab or posts or when the field is downslope of the lowest footing. Water distances are for major water bodies (great ponds, rivers, streams, tidal waters and other waters shown in blue on USGS maps); waters not on USGS maps need 50 ft, and the site evaluator may cut the tank distance from a major water body to 50 ft for a watertight or one-piece tank. Municipal Local Plumbing Inspectors issue permits.
Maryland100* / 10 / none set / 100*100* / 10 / none set / 100*COMAR 26.04.02.04J and .05B. The rule’s definition of an on-site system includes the tank, so these distances apply to the whole system. Well: 100 ft in unconfined aquifers, 50 ft in confined. Water bodies 100 ft. Also 25 ft from steep slopes and drainage ways. No statewide septic-to-property-line distance.
Massachusetts50 / 10 / 10 / 25100 / 20* / 10 / 50310 CMR 15.211 (Title 5). Field to cellar wall 20 ft, to slab 10 ft. Local boards of health may be stricter. MassDEP and the local board of health.
Michigan50 / set by your local health department / set by your local health department / set by your local health department50 / set by your local health department / set by your local health department / set by your local health departmentMich. Admin. Code R 325.1622 (well code). Michigan has no statewide septic code for houses; the 50 ft figure comes from the well code. Statewide bill SB 771 was not law as of Nov. 20, 2026.
Minnesota50 / 10 / 10 / 50-150*50* / 20 / 10 / 50-150*Minn. R. 7080.2150 subp. 2, Table VII; 4725.4450; 6120.3400. Wells are set by the state well code: 50 ft for the tank and the field, and 100 ft from the field for a sensitive well (less than 50 ft of watertight casing that does not pass through a 10 ft confining layer). Lake and river distances are set by the DNR shoreland class and measured from the ordinary high water level: 150 ft for natural environment lakes, 75 ft for recreational development lakes, 50 ft for general development lakes, and 75 to 150 ft for rivers. Local governments enforce these through their shoreland ordinances. Counties, and some cities and townships, issue SSTS permits.
Mississippi50 / 5 / 10 / none set100 / 5 / 10 / 50*15 Miss. Admin. Code 18-77-5.1.3 and 5.4.4. Field 50 ft from sensitive waters: waters used for swimming, skiing or fishing, shellfish harvesting or a drinking-water intake. Public wells same as private: tank 50 ft, field 100 ft. No statewide tank-to-water distance is set. An MSDH environmentalist evaluates the site and MSDH issues approvals.
Missouri50 / 5* / 10 / 50*100 / 15* / 10* / 50*19 CSR 20-3.060, Table 1 (PDF). Effective Dec. 30, 1995, with no later amendments. Building foundation: tank 5 ft, field 15 ft; basement: tank 15 ft, field 25 ft. Water figure is for a classified stream, lake or impoundment (permanent flow or pools in drought); a stream or open ditch is 25 ft for both. Field to property line: 25 ft downslope is recommended for a new system, repairs may go to 10 ft. Wells with less than 80 ft of casing or unplugged abandoned wells: 150 ft from all components. Public wells 300 ft. Ask your local public health agency about permits.
Montana50* / 10 / 10 / 50100* / 10 / 10 / 100Admin. R. Mont. 17.36.918, Table 1. These are the state minimum standards every local board of health must adopt. Well distances are for individual and shared drinking water wells and apply unless DEQ has approved a smaller well isolation zone under Circular DEQ-20. Public or multiple-user wells and springs: 100 ft from the tank and the field. Building distance is to foundation walls. Water means surface water and springs; the rule does not say how it is measured. Drainfields must also be 100 ft from a floodplain. Easements may be used to meet the lot line distance, and the local health authority may require greater distances. Lots in a subdivision are reviewed under ARM 17.36.323, which uses the same distances. Local boards of health or local health officers issue permits.
Nebraska50 / 15* / 5 / 50100 / 30* / 5 / 50124 NAC 2-011, Table 2.1. Building distances shown apply when any part of a basement, footing, pool or living-quarters slab is lower than the tank or field. If the house sits higher than the system, tank and field are both 10 ft; a slab not used as living quarters is 7 ft tank, 10 ft field. A neighbor’s lower foundation is 25 ft tank, 40 ft field. Public community wells 500 ft. DWEE must permit every system before construction, and the work must be done or directly supervised by a certified professional, engineer or registered environmental health specialist.
Nevada100 / 8 / 10 / 100100-150* / 8 / 10 / 100NAC 444.792. Field to a water supply well is 100 ft if the well is sealed to 50 ft and 150 ft if it is not; the tank is 100 ft either way. Public water supply wells: 150 ft from the tank and field. Water means streams or watercourses; drainage channels are 25 ft. Distances are measured in the clear from the edge of each component. In fast-percolating soil the administrative authority may increase well and watercourse setbacks. These State Board of Health rules apply except in health districts that have adopted their own, such as Southern Nevada Health District (Clark County) and Northern Nevada Public Health (Washoe County). The Central Nevada Health District permits systems in Churchill, Eureka, Mineral and Pershing counties; elsewhere the state Environmental Health Section, now part of the Nevada Health Authority, permits house systems. NDEP permits most commercial systems.
New HampshireNot confirmed – check your local code. New Hampshire readopted its septic rules (Env-Wq 1000) with amendments effective February 1, 2026. NHDES approves septic designs before construction. Rule: N.H. Env-Wq 1000 (readopted eff. Feb. 1, 2026).
New Jersey50 / 10* / 5* / 25100* / 25* / 10* / 50N.J.A.C. 7:9A-4.3, Table 4.3. Tank to building may drop to 5 ft with approval. Field to building 15 ft on a slab foundation. Field to well may drop to 50 ft with deep casing. Pool: 10 ft from tank, 20 ft from field. The local board of health administers.
New Mexico50 / 5 / 5 / 50*100 / 8 / 5 / 100*20.7.3.302 NMAC, Table 302.1. Rule effective Sept. 1, 2013, last amended Sept. 15, 2014. Water figures are for watercourses and other waters of the state. Unlined canals, drainage ditches and arroyos are 15 ft from the tank and 25 ft from the field, and lined canals 10 ft, each plus the depth of the channel. Water distances are measured from the edge of the defined bank. Public drinking water wells: 100 ft from the tank and 200 ft from the field. Seepage pits must be 8 ft from lot lines and buildings. The New Mexico Environment Department issues permits; unincorporated Bernalillo County is covered by a county ordinance.
New York50* / 10 / 10 / 50100* / 20 / 10 / 10010 NYCRR Appendix 75-A.4, Table 2. Field to well is 200 ft when the system is uphill in the well’s drainage path, and distances rise 50% where water enters a well less than 50 ft deep. Stricter local and Adirondack Park Agency rules apply in places.
North Carolina50 / 5* / 10 / 50*50 / 5* / 10 / 50*15A NCAC 18E .0601, Table IX (effective Jan. 1, 2024). Foundation 5 ft; basement, cellar or in-ground pool 15 ft. Community or shared wells: 100 ft. County health department.
North Dakota100* / 10 / 10 / none set*100* / 10 / 10 / 100*N.D. Admin. Code 62-03.1-03-04. Well distances are for wells less than 100 ft deep; wells more than 100 ft deep need 50 ft. The rule does not separate public and private wells. The table sets no general distance from the septic tank to surface water. Where a reservoir or tributary stream feeds a potable water intake, tanks and fields less than 3,000 ft upstream of the intake must be 200 ft from the high water level or stream bank, and those farther upstream 100 ft. This 2000 State Plumbing Board rule is still in the code. The Department of Environmental Quality now has authority over onsite system rules, but its proposed rules were held over by the Legislature’s Administrative Rules Committee on Sept. 14, 2026, and were not in the code as of Nov. 23, 2026. Local public health units issue permits.
Ohio50 / 10 / 10 / none listed50 / 10 / 10 / 50Ohio Adm. Code 3701-29-06(G)(3). Absorption components sit 50 ft from lakes, rivers, wetlands and perennial streams. All components sit 10 ft from intermittent streams and swales. The rule lists no tank-to-stream distance.
OklahomaNot confirmed – check your local code. Statewide distances are set in Appendix E of the DEQ on-site sewage rules (OAC 252:641). Before installing a system, the installer must get DEQ authorization to construct under the general permit, or an individual permit for an alternative system. Rule: OAC 252:641, Appendix E.
Oregon50 / 5 / 5 / 50*100* / 10 / 10 / 100*OAR 340-071-0220(1)(j); OAR 340-071-0800, Table 1. Field 100 ft from wells, or 50 ft for wells built under special standards granted by the Water Resources Department; Table 1 sets no separate public well distance. Field 100 ft from year-round surface public waters and 50 ft from seasonal ones. Intermittent streams are 50 ft from tank and field, or 20 ft if piped watertight. Water is measured from the bank drop-off or mean yearly high water mark, whichever gives the greater distance. On lots created before May 1, 1973, the agent may approve a surface water setback under 100 ft but not less than 50 ft. Building distances apply to the foundation line of any building, including garages and outbuildings. Rule amended effective Jan. 1, 2026; the Table 1 distances are the same as in 2014. DEQ or a county acting as DEQ’s contract agent issues permits.
Pennsylvania50 / 10 / 10 / 25100 / 10 / 10 / 5025 Pa. Code 73.13. Wetlands are not surface waters under Chapter 73. The 72.33 well exemption applies to the absorption area only. For the full Pennsylvania breakdown, see our Pennsylvania septic and well setbacks page.
Rhode Island75 / 5 / 10 / 25100* / 25* / 10 / 50250-RICR-150-10-6, Sec. 6.23. Well distances of 100 or 75 ft for the tank, and 150 ft for the leachfield in some conditions (80 ft with conditions). Foundation 15 ft where there is no foundation drain. RIDEM approves plans.
South Carolina75 / 5 / 5 / 7575 / 5* / 5 / 75R.61-56, Sec. 200.6 (PDF). Public well 100 ft. Field to basement 25 ft upslope, 15 ft at the sides. In-ground pool 15 ft. SCDES.
South Dakota50-75* / 10 / 10 / 50100-150* / 20 / 10 / 100ARSD 74:53:01:19, Table 1. The lower well distance applies to wells over 100 ft deep; the higher one applies to wells less than 100 ft deep, springs and water suction lines. The rule does not separate public and private wells. Building means a dwelling or occupied building. Water is measured from the high-water line of lakes, streams or impoundments, meandered or ordinary, whichever is higher. Installers must be state certified. A conventional system (a septic tank followed by an absorption system) can be designed and installed without sending plans to the state; other systems need plan approval from DANR before construction. Local governments may have stricter rules.
Tennessee50 / 5 / 10 / 15*50 / 10 / 10 / 25*Tenn. Comp. R. 0400-48-01-.11. Water figures are the streams, gullies and sinkholes row. The Commissioner may adjust distances after a soil investigation.
Texas50 / 5 / 5 / 50100* / 5 / 5 / 75*30 TAC 285.91(10), Table X. Field 100 ft from private wells and underground cisterns, 50 ft from wells completed under specified parts of 16 TAC 76.100. Public wells 150 ft from the field and 50 ft from the tank. Water is measured from normal pool elevation; low-pressure dosed fields with secondary treatment and disinfection may be 50 ft. TCEQ or a local authorized agent, such as a county or city, issues permits.
Utah50* / 5* / 5 / 25100* / 5* / 5 / 100Utah Admin. Code R317-4-13, Table 2. Rule last amended June 29, 2023, and continued after a five-year review in Jan. 2025. A table note sets 200 ft from an ungrouted well or spring (a private well without a 30 ft deep grout seal) but does not say whether it covers the tank, the field or both; exceptions may be approved, but never closer than 100 ft. Public water sources are 100 ft from the tank and field, and must also meet the state drinking water source protection rules. Building distances are for a foundation without a foundation drain; with a foundation drain the tank is 10 ft and the field 100 ft, which may be cut to no less than 20 ft if effluent will not enter the drain. A deep wall trench or seepage pit must be at least 20 ft from any foundation. Water covers lakes, ponds, reservoirs, streams, rivers and canals, measured from the high water line. Local health departments administer the rule and may set stricter requirements.
Vermont50* / 10 / 10 / 25100* / 20* / 25 / 50Vt. Wastewater Rules Sec. 1-912, Tables 9-3 and 9-4. Well in bedrock or a confined aquifer: the field must be 100 ft from the well where the ground is at or below the well’s elevation, and 200 ft where it is higher or detailed topography is not available; tank 50 ft. Well in an unconfined surficial aquifer: field 150 to 500 ft, tank 75 ft. Field 75 ft from a building with a foundation drain that sits downslope of the field, otherwise 20 ft. Surface water is measured from normal high water. The Agency of Natural Resources, or a town with delegation, issues the permit.
Virginia50 / 10* / 5 / 5050* or 100* / 10* / 5 / 50*12VAC5-610-592, Tables 4.1 and 4.2. Field to well is 50 ft for Class IIIA and IIIB soils and 100 ft for Class IIIC and IV. Basements 20 ft. Field to stream may drop to 10 or 20 ft with an unsaturated-flow design.
Washington50 / 5 / 5 / 50100 / 10 / 5 / 100WAC 246-272A-0210, Table IV (effective April 1, 2025). Field means the edge of the soil dispersal component and reserve area. Surface water is measured from the ordinary high-water mark. Public drinking water well: 100 ft; public drinking water spring or surface water: 200 ft. The local health officer may increase distances, may reduce to not less than 2 ft where the property line, easement or foundation is up-gradient, and may allow 75 ft field-to-well, spring or surface water that is not a public water source, with site conditions or enhanced treatment. Local health jurisdictions permit.
West Virginia50 / 10 / 10 / none listed100 / 10 / 10 / 2064 CSR 47, Sec. 6.2 and Table 64-47K (effective July 1, 2025). Field sits 20 ft from stream banks and open drainage. No tank-to-stream distance is listed. No system under paving or structures.
Wisconsin25 / 5 / 2 / 1050 / 10 / 5 / 50Wis. Admin. Code SPS 383.43, Table 383.43-1; NR 812.08 Table A. Water distances are measured from the ordinary high-water mark of navigable waters. Well distances come from the DNR well code: 25 ft for septic and holding tanks, 50 ft for the dispersal area, 200 ft from a school well. Swimming pools 15 ft from the dispersal area. Road right-of-way lines may be stricter than property lines. The local governmental unit issues the sanitary permit (DSPS for state-owned land).
Wyoming50 / 5 / 10 / 50100 / 10* / 10 / 50WDEQ Water Quality Rules Ch. 25, Sec. 7, Table 4. Rule last amended June 29, 2018. Wells include neighboring wells. The field is 10 ft from a foundation wall without drains and 25 ft from one with drains. Public water supply wells: 100 ft from the tank and 200 ft from the field; systems in the same aquifer within Zone 1 or 2 of a public well need added treatment and an individual permit. Water includes springs and seasonal and intermittent surface water. WDEQ issues permits in Carbon, Niobrara, Platte and Weston counties and for commercial systems in Campbell County; elsewhere a delegated local small wastewater program issues them.

Last checked November 23, 2026. A row marked “not yet verified” has not been checked against the state’s rule text; use your local health department’s number, not a guess. Looking for wells? See well setbacks by state.

In Pennsylvania

Tank 50 ft and absorption area 100 ft from a well, 10 ft from buildings and property lines, 25 ft and 50 ft from surface water. Details are on our Pennsylvania septic and well setbacks page.

Questions

What is a septic setback?

The minimum distance, in feet, a tank or drain field must be from a well, a building, a property line or a stream or lake. States set the minimums; your county or town health department can require more.

Why is the drain field set farther from a well than the tank?

In most states that have a table, the drain field is the larger setback because it releases effluent into the soil. Pennsylvania, for example, uses 50 ft for the tank and 100 ft for the absorption area.

Why do some rows say “Not confirmed”?

We only list a number once we have read it in the state’s own rule. Where we have not yet done that, the row says so, and your local health department has the real figure.

Sources: each confirmed state’s rule is linked in its row. Checked November 23, 2026.

Muthler Landscaping & Construction · Lock Haven, PA

Planning a patio, wall or addition near a septic system?

We lay out hardscape and site work in Clinton, Centre, Lycoming and Union counties so it stays clear of tanks, fields and wells.

Get a quoteWell setbacks by state

Muthler Landscaping & Construction LLC · 913 Bellefonte Ave, Lock Haven, PA 17745 · (570) 397-9800 · PA HIC #PA212584.