Constructed filter (sand filter): how the PA BMP Manual describes it

Quick answer: In the Pennsylvania Stormwater Best Management Practices Manual, a constructed filter is a structure or excavation filled with media such as sand, peat or compost that strains pollutants out of runoff, then collects the filtered water in an underdrain. The manual sets a 12-inch minimum media depth, a 72-hour drawdown recommendation and a positive overflow.

What it is

BMP 6.4.7 is titled “Constructed Filter,” and sand is only one of the media it covers. The manual describes a structure or excavation filled with sand, peat, compost, granular activated carbon, perlite or another approved material that removes sediment, metals, hydrocarbons and other pollutants. Runoff may first pass through an open-air pretreatment chamber where large particles settle, or across surface vegetation. It then moves through the media, is collected by an underdrain, and is returned to the conveyance system, receiving waters or the soil, depending on the design. Other media may be used if data shows they meet performance goals. This is a different section from the manufactured units in our guide to water quality filters and hydrodynamic devices, although the manual lists manufactured systems as one variation here.

Ratings in the manual

The manual lists estimated pollutant removal of 85% for total suspended solids, 85% for total phosphorus and 30% for nitrate, with water quality rated high. Volume reduction, recharge and peak rate control are rated from low to high, depending on whether infiltration is used. Commercial, ultra-urban, industrial, retrofit and highway uses are marked as suitable, while residential use is marked limited. Typical settings are urban areas with high pollutant loads and little space, such as parking lots, roads, light industrial sites, marinas and fast food or shopping areas. The manual also lists pretreatment ahead of wet ponds or infiltration systems and hot spot treatment.

Key design numbers

ItemWhat the manual says
Media depthMinimum 12 inches in the key elements; typical 12 to 30 inches
Minimum hydraulic conductivitySand 3.5 ft/day, peat 2.5 ft/day, leaf compost 8.7 ft/day
Gravel layerAt least 6 inches beneath the media
UnderdrainPerforated pipe, laterals no more than 10 feet apart, cleanouts reaching the surface
DrawdownRecommended not to exceed 72 hours
SandASTM C-33 or AASHTO M-6, clean medium-to-fine concrete sand, no organic material
Void space for volume credit20% for sand, amended soil, compost and peat unless better data exists

The sizing formula is A = V x d / (k x t x (h + d)), where A is filter surface area, V is water volume, d is media depth (minimum 1.5 ft, maximum 2.5 ft), t is drawdown time in days, h is average head and k is hydraulic conductivity. For a filter that infiltrates, the manual adds infiltration volume (bottom area times infiltration rate times drawdown time) to filter volume (filter area times depth times 20%). Peak rate and water quality calculations are referred to Chapter 8.

Variations the manual lists

  • Surface non-vegetated filter: built by excavation or in a container, surfaced with sand, peat, gravel or river stone.
  • Vegetated filter: plants grow on the media, with a nonwoven geotextile separating topsoil from sand. Compost-amended soil can also be the media.
  • Infiltration filter: part of the treated water may soak in, so infiltration criteria apply and a positive overflow is recommended.
  • Contained filter: no infiltration, using a precast concrete box or an excavation with an impermeable liner.
  • Linear perimeter filter: enclosed chambers such as trench drains along an impervious edge, or vegetated perimeter areas.
  • Small and large subsurface filters: an inlet filter that works like a water quality insert, or a two-chamber underground box that settles large particles and then filters fine ones.
  • Manufactured systems: product-specific data must come from the manufacturer.

The section does not describe Delaware or Austin filter variants by name.

Design considerations

Larger storms should overflow or bypass, and a flow splitter can make an off-line filter that controls the volume and speed of water entering it. Entry velocity can be controlled with a level spreader, sheet flow or river stone edges (see level spreader). Where debris or sediment loads are high, the manual suggests oil and grit separators, vegetated filter strips or grass swales ahead of the filter. Coarser media passes water faster and finer media catches smaller particles. The manual says sand balances the two and is reliable for suspended solids, and that peat removes slightly more phosphorus, copper, cadmium and nickel than sand. Sediment buildup lowers conductivity and removal, so some or all of the media may eventually need replacing, and designs that are visible and simple tend to be maintained better.

Construction sequence in brief

  1. Do not install permanent filters until the site is stabilized and all contributing areas are stabilized.
  2. For infiltrating filters, excavate without compacting the subbase and place a nonwoven geotextile underneath.
  3. Place gravel in lifts of at least 6 inches, lightly compacting, and set the underdrain pipes in it.
  4. Wrap and secure the fabric so sediment cannot clog the gravel.
  5. Lay the media without compacting it, then saturate it and let it drain so it settles evenly.
  6. Leave enough head space between the top of the bed and the overflow for the maximum design storage depth.

Maintenance and winter

The manual says to inspect at least four times a year. Standing water after the design drawdown time means the filter is not working well, and film or discoloration on the surface suggests organics or debris are clogging it. Maintenance includes removing trash, raking off silt, tilling and aerating the surface, and replacing media if its depth has been reduced. Media that collects toxic pollutants such as metals must be disposed of under state and federal rules. The manual notes that Pennsylvania temperatures are below freezing about four months a year, which reduces surface filtration, and that peat and compost can freeze and become impervious.

Costs

The manual gives no dollar figures or years for this practice. It says cost depends on media type, clearing, excavation, grading, inlet and outlet structures, perforated pipe, any enclosing structure and maintenance, and that underground structures can add significantly to the cost.

Where the manual contradicts itself

  • Underdrain size: design considerations call for perforated pipe at least 4 inches in diameter, while the pipe specification calls for at least 8 inches inside diameter.
  • Media depth: the key elements give a 12-inch minimum, but the sizing formula sets a minimum depth of 1.5 ft (18 inches).
  • Drawdown units: the formula uses days while the limit is stated as 72 hours.
  • Infiltration volume: the infiltration volume sentence multiplies inches per hour by hours without the 1/12 conversion that the infiltration trench section uses.

Pennsylvania approvals and who designs it

Sizing, media selection and overflow design need a qualified professional such as a licensed engineer, and a filter used for stormwater control may need approval from your municipality, the county conservation district or DEP. Check whether an erosion and sediment plan or NPDES permit applies (see Chapter 102 and PA stormwater plan rules). Related parts include perforated drain pipe and drainage geotextile fabric.

Sources

  • Pennsylvania Department of Environmental Protection, Pennsylvania Stormwater Best Management Practices Manual (363-0300-002, December 30, 2006), BMP 6.4.7 Constructed Filter, via the PA DEP eLibrary. Checked Nov 23, 2026.

Related

All drainage guides · Infiltration trench · Catch basins and area drains · Soil infiltration rate

Get a quote

FAQ

How deep is the media in a constructed filter?

The manual gives a 12-inch minimum and a typical range of 12 to 30 inches, but its sizing formula sets a minimum of 1.5 ft.

How long should the filter take to drain?

The manual recommends a drawdown not to exceed 72 hours.

Does the filter have to be sand?

No. The manual also covers peat, compost, granular activated carbon, perlite and other approved media.

Does a constructed filter work in winter?

The manual says freezing reduces surface filtration in Pennsylvania and that peat and compost can freeze and become impervious.

Planning information only. Design must be done by a qualified professional and approved by your municipality and, where required, DEP. Source checked Nov 23, 2026.