Water Quality Filters and Hydrodynamic Devices: What the PA Stormwater BMP Manual Says
Water quality filters and hydrodynamic devices: how the PA BMP Manual describes them
Quick answer: In the Pennsylvania Stormwater Best Management Practices Manual, BMP 6.6.4 covers manufactured inlet inserts, sumps and hydrodynamic devices that settle and filter particulates, oil and debris from piped runoff. They reduce no volume or peak rate, and the manual says regular maintenance is critical.
What they are
These are structural devices that use settling and filtration to remove particulates from conveyance runoff, aimed mostly at particulates, oil and grease, litter and debris. The manual says hydraulic capacity controls effectiveness, that they are most useful in small drainage areas under 1 acre, and that they work best combined with other BMPs. Volume reduction, recharge and peak rate control are all None, and water quality is Medium. Stated removal is 60% for TSS, 50% for phosphorus and 20% for nitrate, and the manual adds that manufacturers’ specifications should be checked for estimated efficiencies.
Types in the manual
- Tray type: filter media in a perimeter tray, with high flows passing over.
- Bag type: a fabric insert around the grate, sometimes with polymers, with overflow holes.
- Basket type: a removable basket with small orifices, mainly for debris and larger sediment, needing frequent maintenance.
- Sumps: 6 to 12 inches of space below the pipe invert, with weep holes recommended.
- Hydrodynamic devices: baffle plate, vortex, tube settler, inclined plate settler or combinations. Clays and fine silts need coagulants or polymers to settle.
Typical applications are parking lots, gas stations, golf courses, streets, driveways, industrial and commercial sites and municipal yards, often as pretreatment. Inlet inserts can help with hot spots. Our page on catch basins and area drains covers the structures these devices go into.
Design, construction and upkeep
Six design considerations apply: follow the manufacturer’s guidance for the land use, prevent resuspension, make retrofits fit existing inlets, provide maintenance access, reconfigure the device if it was used for construction erosion control, and bypass storms above hydraulic capacity to another BMP. Stabilize contributing areas before connecting pipes. Do not use inserts during construction unless they are designed mainly for sediment, and install adsorption components after construction.
During construction, inspect weekly. Afterward, empty when more than half full of sediment and trash, clean at least twice a year and inspect after runoff events. Winter data is limited; freezing can cause bypass and salt can slow settling. Hot-spot waste must follow DEP solid waste rules.
Waste handling and winter limits
Sediment pulled from these devices is waste. The manual says hot-spot waste must follow DEP solid waste rules, while lawn-type waste may be reused onsite, and notes that vactor trucks are an efficient way to clean sumps and inlets. Because volume reduction and peak rate figures do not apply, water quality performance is left to manufacturer specifications and tests. Salt and sand increase maintenance needs in winter, and the manual says freezing can also cause bypass and salt stratification, so a device that works in July may behave differently in January.
Where the manual is unclear or inconsistent
- Emptying threshold: empty when over half full, yet the manual cites a 1985 study saying inserts can store sediment up to 60% of sump volume before inflow resuspends it. The two thresholds are not reconciled.
- Dissolved pollutants: hydrodynamic devices are said to remove dissolved solids and nutrients, but no dissolved or nutrient figures are given beyond the 50% phosphorus and 20% nitrate numbers.
- Fine particles: clays and fine silts are said not to settle easily, yet 60% TSS removal is listed with no particle-size qualifier.
- Small areas: under 1 acre is stated in the key elements, while the design consideration on resuspension gives no number.
- Costs: the manual gives no figures and no year, only to check with manufacturers for current prices.
Pennsylvania approvals and who designs it
Product selection, sizing and tie-in to a storm sewer need a qualified professional such as a licensed engineer, and the manual defers specifications to the manufacturer. Devices used for stormwater compliance may need approval from your municipality, the county conservation district or DEP. See PA stormwater plan rules and Chapter 102.
Sources
- Pennsylvania Department of Environmental Protection, Pennsylvania Stormwater Best Management Practices Manual (363-0300-002, December 30, 2006), BMP 6.6.4 Water Quality Filters & Hydrodynamic Devices, via the PA DEP eLibrary (greenport.pa.gov). Checked Nov 23, 2026.
Related
All drainage guides · Trench (channel) drains · Vegetated filter strip
FAQ
What drainage area suits these devices?
The PA BMP Manual says they are most useful in small drainage areas under 1 acre.
How much do they remove?
The manual lists 60% TSS, 50% phosphorus and 20% nitrate, and says to check manufacturers’ specifications for efficiencies.
When should an insert be emptied?
The manual says when over half full of sediment and trash, and cleaned at least twice a year. It also cites a 60% sump-volume resuspension point, which it does not reconcile.
Do they reduce runoff volume?
No. The manual lists volume reduction, recharge and peak rate control as None.
Planning information only. Design must be done by a qualified professional and approved by your municipality and, where required, DEP. Source checked Nov 23, 2026.