Welding and Cutting on Job Sites: OSHA 1926.350 to 1926.354 Cylinders, Arc Welding, Fire Watch and Ventilation
Welding and cutting on job sites: OSHA 1926.350 to 1926.354
Quick answer: OSHA’s construction welding and cutting rules sit in Subpart J, sections 1926.350 to 1926.354. They cover compressed gas cylinders and fuel gas (1926.350), arc welding equipment (1926.351), fire prevention (1926.352), ventilation and protection (1926.353) and welding on coated surfaces (1926.354). Oxygen cylinders must be stored at least 20 feet from fuel-gas cylinders or combustibles, or behind a noncombustible barrier at least 5 feet high with a half-hour fire rating.
Site crews cut rebar, torch off old fasteners, weld brackets and repair buckets and attachments. Each of those jobs brings in this subpart. This page covers the five sections as shown on Cornell’s Legal Information Institute. Check the current CFR text at ecfr.gov before relying on any number. For general job site fire rules see our fire protection page.
Gas welding and cutting: 1926.350
Section 1926.350 starts with cylinder handling. Valve protection caps must be in place and secured when cylinders are moved. Hoisted cylinders must sit on a cradle, slingboard or pallet; magnets and chain slings are prohibited. Cylinders are moved by tilting and rolling on their bottom edges, and cylinders moved by powered vehicle must be upright. Caps may not be used to lift cylinders, and bars may not pry frozen cylinders loose. Cylinders must be kept from being knocked over in use, and the valve closed when work is finished, the cylinder is empty or it is moved. Oxygen cylinders must be stored at least 20 feet from fuel-gas cylinders or combustibles, or behind a noncombustible barrier at least 5 feet high with a half-hour fire rating. Indoor storage must be dry, ventilated and protected, at least 20 feet from highly combustible materials. Cylinders must not become part of an electrical circuit, and oxygen, acetylene and other fuel-gas cylinders may not be taken into confined spaces.
| Topic | Rule |
|---|---|
| Valve opening | Open slowly; for quick shutoff, no more than 1 1/2 turns |
| Manifold labels | Contents named in letters at least 1 inch high |
| Hose taped together | No more than 4 of every 12 inches covered |
| Hose inspection | At the start of each shift; defective hose removed |
| Hose tested after flashback or severe wear | At twice normal pressure, minimum 300 psi |
| Torch inspection | At the start of each shift for leaks at valves, couplings and tips |
| Lighting torches | Friction lighters or other approved devices, not matches or hot work |
The section also says oxygen cylinders and fittings must be kept away from oil and grease, that oxygen may not be directed at oily surfaces or greasy clothing, and that only the gas supplier may mix gases in a cylinder. Damaged or defective cylinders may not be used. The employer must instruct employees thoroughly in the fuel gas practices. For details not covered, the section points to the technical portions of ANSI Z49.1-1967.
Arc welding and cutting: 1926.351
Electrode holders must be designed for arc welding and rated for the maximum current, with current-carrying parts in the grip and the outer jaw surfaces fully insulated. Welding cables must be completely insulated and flexible and sized for the work. For at least 10 feet from the electrode-holder end, only cable without repairs or splices may be used. Cables needing repair may not be used. A ground return cable must carry at least the rated maximum output of the unit it serves. Pipelines carrying gases or flammable liquids, and conduits carrying electrical circuits, may not be used as ground returns. Machine frames must be grounded, and ground connections must be inspected for mechanical strength and electrical adequacy.
The operating instructions are practical: remove electrodes from unattended holders and protect the holders from contact, never dip hot electrode holders in water, open the power switch when leaving work or before moving the machine, and report faulty equipment to a supervisor. Where practicable, arc operations must be shielded by noncombustible or flameproof screens that protect nearby employees from the arc’s direct rays. Our job site electrical safety page covers related cord and power rules.
Fire prevention: 1926.352
- Move the work to a designated safe spot when practical, or remove or protect movable fire hazards nearby.
- If hazards cannot be moved, use firm measures to contain heat, sparks and slag and shield fixed hazards.
- Do not perform hot work where flammable paint, flammable compounds or heavy dust concentrations create a hazard.
- Keep suitable fire extinguishing equipment immediately available in the work area.
- Where normal precautions are not enough, assign fire watchers during the work and for a sufficient time afterward, briefed on the hazards and the equipment.
- For work on walls, floors or ceilings, take the same precautions on the opposite side.
- In enclosed spaces, shut off the torch gas supply outside the space whenever the torch is unused for a long period, and remove torches and hoses overnight and at shift changes.
Before hot work on drums, containers or hollow structures that held toxic or flammable substances, they must be filled with water, or cleaned, ventilated and tested. Before heating a closed container, a vent or opening must release built-up pressure. See our flammable liquids page.
Ventilation and protection: 1926.353
Ventilation must be general mechanical ventilation or local exhaust. Oxygen may not be used for ventilation, comfort cooling, blowing dust off clothing or cleaning the work area. In a confined space, ventilation is required, and if it cannot be achieved without blocking access, employees inside must wear airline respirators with an outside employee in communication. A welder entering through a manhole needs a means of quick removal, and an attendant with a pre-planned rescue procedure must stay outside. For metals of toxic significance, enclosed-space work on zinc-bearing metals or coatings, lead base metals, cadmium-bearing filler or chromium-bearing metals or coatings requires ventilation. Work on lead-bearing, cadmium-bearing, mercury-coated or beryllium-containing metals in enclosed spaces needs local exhaust or airline respirators, and open-air work needs filter-type respirators, with airline respirators for beryllium. For inert-gas metal-arc welding, chlorinated solvents must be kept at least 200 feet from the exposed arc unless shielded. All employees doing welding, cutting or heating must have suitable eye protection. See our confined spaces page and lead in construction page.
Coated surfaces: 1926.354
Before welding, cutting or heating a surface with a preservative coating of unknown flammability, a competent person must test the coating. If it is highly flammable, it must be stripped from the area to be heated. Toxic coatings in enclosed spaces must be stripped for at least 4 inches from the heated area, or employees must have supplied-air respirators. In the open air, employees must wear a respirator that meets Subpart E. Coatings must be removed far enough that the unstripped metal does not get significantly hotter.
Practical checklist for a hot work day
- Walk the area and look behind and below the work for combustibles.
- Stand cylinders upright, secured, away from sparks, with caps on when moving.
- Inspect hose, torch and cables at the start of the shift.
- Put an extinguisher within reach and assign a fire watcher when the area calls for it.
- Test or strip coatings, and plan ventilation before you strike an arc in a tank or trench.
Sources
| Source | Used for |
|---|---|
| 29 CFR 1926.350, Gas welding and cutting (Cornell LII) | Cylinders, hose, torches |
| 29 CFR 1926.351, Arc welding and cutting (Cornell LII) | Holders, cables, grounding |
| 29 CFR 1926.352, Fire prevention (Cornell LII) | Fire watch and precautions |
| 29 CFR 1926.353, Ventilation and protection (Cornell LII) | Ventilation and toxic metals |
| 29 CFR 1926.354, Preservative coatings (Cornell LII) | Coating tests and stripping |
Checked Nov. 23, 2026. Check the current CFR text at ecfr.gov before relying on details.
Related
Fire prevention and storage · Eye and face protection · Hand and power tools · All PA site work regulations
FAQ
How far apart must oxygen and fuel-gas cylinders be stored?
Section 1926.350(a)(10) says at least 20 feet, or behind a noncombustible barrier at least 5 feet high with a half-hour fire rating.
Does OSHA require a fire watch for welding?
Section 1926.352(e) says where normal precautions are not enough, additional personnel must be assigned as fire watchers during the work and for a sufficient time afterward.
Can a gas pipe or electrical conduit be used as a welding ground?
No. Section 1926.351(c)(2) says pipelines carrying gases or flammable liquids, and conduits carrying electrical circuits, may not be used as ground returns.
What must be done before welding on a coated surface?
Section 1926.354 requires a competent person to test a coating of unknown flammability, and highly flammable coatings must be stripped from the area to be heated.
General information only, not legal or safety advice. Employers must follow the current OSHA standard and applicable Pennsylvania rules. Source pages checked Nov. 23, 2026.