Skip to content Groundwork Design Co.Want a design?Custom patio, wall, deck and yard plans, drawn by builders. Anywhere in the U.S. From $349.Start here
LOCK HAVEN, PA · PA HIC #PA212584 · INSURED FREE ESTIMATES · CALL OR TEXT
PAGE
Home / PA site regulations / Confined spaces in construction

Confined spaces in construction: OSHA Subpart AA basics

Quick answer: Under 29 CFR 1926.1202 a confined space is one large enough to enter, with restricted ways in and out, that is not designed for continuous occupancy. A permit-required space adds a serious hazard, and 1926.1203 says a competent person must identify these spaces before work starts.

What Subpart AA covers

Subpart AA of 29 CFR 1926 is titled Confined Spaces in Construction. The sections listed on OSHA’s page are 1926.1201 Scope, 1926.1202 Definitions, 1926.1203 General requirements, 1926.1204 Permit-required confined space program, 1926.1205 Permitting process, 1926.1206 Entry permit, 1926.1207 Training, 1926.1208 Duties of authorized entrants, 1926.1209 Duties of attendants, 1926.1210 Duties of entry supervisors, 1926.1211 Rescue and emergency services, 1926.1212 Employee participation and 1926.1213 Provision of documents to Secretary. Section 1926.1200 is marked Reserved.

Section 1926.1201(a) says the standard sets forth requirements for practices and procedures to protect employees engaged in construction activities at worksites with confined spaces. Paragraph (b) says it does not apply to work regulated by Subpart P (Excavations), Subpart S (Underground Construction, Caissons, Cofferdams and Compressed Air) or Subpart Y (Diving). That carve-out matters for excavation crews, because open trench work is handled under the excavation rules covered in our trench protection basics page.

The definitions that decide everything

Under 1926.1202, a confined space is a space that is large enough and so configured that an employee can bodily enter it, has limited or restricted means of entry or exit, and is not designed for continuous employee occupancy. The label depends on those traits, not on what the structure is called.

A permit-required confined space, or permit space, is a confined space with one or more of four traits: it contains or could contain a hazardous atmosphere; it contains material that could engulf an entrant; its internal shape could trap or asphyxiate an entrant, such as inward-converging walls or a sloping, tapering floor; or it contains any other recognized serious safety or health hazard.

What counts as a hazardous atmosphere

Section 1926.1202 defines a hazardous atmosphere as one that may expose employees to the risk of death, incapacitation, injury or acute illness from any of these causes:

  • Flammable gas, vapor or mist above 10 percent of its lower flammable limit (LFL)
  • Airborne combustible dust at or above its LFL
  • Oxygen concentration below 19.5 percent or above 23.5 percent
  • A substance exceeding its published dose or permissible exposure limit
  • Any other atmospheric condition that is immediately dangerous to life or health

Engulfment is defined as the surrounding and effective capture of a person by a liquid or finely divided (flowable) solid substance, which can cause death by filling or plugging the airways or by crushing, strangulation or suffocation.

Competent person, signs and keeping people out

The regulation defines a competent person as someone capable of identifying existing and predictable hazards in the surroundings or working conditions who has authority to take prompt corrective measures to eliminate them. Under 1926.1203(a), before work begins a competent person must identify all confined spaces employees may enter and determine which are permit spaces, testing where needed.

If the worksite has permit spaces, 1926.1203(b)(1) requires the employer to warn exposed employees with danger signs or an equally effective method, and a sign reading DANGER, PERMIT-REQUIRED CONFINED SPACE, DO NOT ENTER meets the requirement. Under (b)(2) the employer must promptly inform authorized representatives and the controlling contractor by means other than posting. Under (c), an employer that has not authorized its employees to enter a permit space must take effective steps to keep them out. That last point is the one most small crews need: if you are not set up for permit entry, the answer is that your people do not go in.

If your employer allows entry

Under 1926.1203(d), an employer that allows entry must implement a written permit space program that complies with 1926.1204 and make it available for inspection before and during entry. The program works through the permit, training, entrant, attendant, entry supervisor and rescue sections listed above. The regulation defines an attendant as an individual stationed outside one or more permit spaces who monitors the status of authorized entrants and performs the duties in 1926.1209.

Section 1926.1203(e) allows alternate procedures only if every condition in (e)(1) is met, including eliminating or isolating physical hazards and showing, with documented data, that continuous forced-air ventilation alone keeps the space safe. Paragraph (e)(2) then sets entry requirements such as atmospheric testing, ventilation, continuous monitoring, evacuation when a hazard appears, safe access and egress, and a signed pre-entry certification.

Reevaluation, reclassification and coordination

When a non-permit confined space changes in use or configuration, or the original evaluation seems inadequate, 1926.1203(f) requires a competent person to reevaluate it and reclassify it as a permit space if needed. Paragraph (g) lets a permit space be reclassified as non-permit only when a competent person confirms the requirements in (g)(1) through (g)(4) are met, including eliminating or isolating all hazards and documenting it with a signed certification.

Paragraph (h) covers coordination. The host employer, controlling contractor and entry employers must share permit space information before entry, coordinate work when entries overlap or nearby activities could create hazards, and debrief after entry. Under (i), if there is no controlling contractor, the host employer or the employer arranging the work takes on that role. On a subcontract job, ask the general contractor in writing which spaces on the site have been classified as permit spaces.

Common mistakes

  • Assuming a space is safe because it is shallow or because someone has gone in before.
  • Entering without a competent person having identified and classified the space.
  • Treating oxygen as the only atmospheric concern. The definition also covers flammable gas, combustible dust and toxic substances.
  • Standing at the opening to rescue a collapsed worker instead of following the rescue and emergency services requirements in 1926.1211.
  • Ignoring changes. A space can be reclassified under 1926.1203(f) when its use or configuration changes.

When to get professional help

This page does not replace the regulation. Atmospheric testing, permit programs and rescue planning require trained people and the full text of 1926.1201 through 1926.1213. If a job involves a possible confined space, ask the controlling contractor and a qualified safety professional before anyone enters.

Sources

Sources checked Nov 23, 2026.

Related

OSHA trench protection basics · OSHA competent person for excavations · Fall protection and ladder basics · All PA site work regulations

Talk to us about your project

FAQ

What is a confined space under OSHA’s construction standard?

Under 29 CFR 1926.1202, it is a space large enough that an employee can bodily enter it, with limited or restricted means of entry or exit, and not designed for continuous employee occupancy.

What makes a confined space permit-required?

One or more of four traits: a hazardous atmosphere or the potential for one, material that could engulf an entrant, an internal shape that could trap or asphyxiate, or any other recognized serious safety or health hazard.

What oxygen levels make an atmosphere hazardous?

Section 1926.1202 lists oxygen below 19.5 percent or above 23.5 percent as a hazardous atmosphere, along with flammable gas above 10 percent of its lower flammable limit and other conditions.

Does Subpart AA apply to trenches?

Section 1926.1201(b) says the standard does not apply to work regulated by Subpart P (Excavations), Subpart S or Subpart Y.

General information only, not legal or safety advice. Employers must follow the current OSHA standard and applicable Pennsylvania rules. Source pages checked Nov 23, 2026.