Segmental retaining wall units
Segmental retaining wall (SRW) units are factory-made concrete blocks stacked dry, without mortar, to hold back soil. The unit is only part of the wall: the drainage stone, the base and, on taller walls, the soil reinforcement do much of the work.
What an SRW unit is
The Concrete Masonry and Hardscapes Association (CMHA) describes SRW units as factory-made concrete units for dry-stacked, mortarless retaining walls. Units generally weigh 30 to 100 lb (14 to 45 kg) each, and walls built with them range from low terraces about 8 in. high to walls 20 ft or more in height. Units are covered by ASTM C1372, which includes both solid and hollow types. Faces can be split, stone-faced or molded, and any of these can be scored, ribbed or colored. See the glossary entry on segmental retaining walls.
How the wall resists the soil
CMHA says resistance comes from mechanical interlock, friction or shear capacity between units, and the mass of the units. Shear transfer can come from keys or lips, clips, pins or compacted aggregate in the cores. CMHA separates two wall types:
- Conventional (gravity): dry-stacked units that rely on their own mass to resist sliding and overturning.
- Reinforced soil: horizontal soil reinforcement placed between courses and extending into the backfill, which acts as a composite mass with the soil.
The batter, or course-to-course setback, is in most cases controlled by the location of shear pins or leading or trailing lips on the unit. CMHA says reinforced soil should be specified when the maximum height for conventional gravity walls is exceeded, but it gives no number for that height; the manufacturer’s design information sets it. See geogrid for how reinforcement works.
What ASTM C1372 checks
| Property | How CMHA describes it |
|---|---|
| Compressive strength | Measured on saw-cut coupons, not whole units; preferred coupon 2 x 4 x 8 in. |
| Weight class | Lightweight, medium weight or normal weight by oven-dry density; most SRW units are normal weight |
| Absorption | Limits vary by weight class and are expressed as mass of water per unit volume |
| Dimensions | Permissible variation of +1/8 in. (3.2 mm) from specified dimensions; the width tolerance does not apply to split-faced or other architectural faces |
| Freeze-thaw | Required only where repeated freezing and thawing under saturated conditions occurs |
| Appearance | No chips or cracks visible from at least 20 ft in diffused light; up to 5% of a shipment may have defects |
The numeric strength, density and absorption limits sit in a table of the standard that the CMHA summary does not reproduce, so we do not state them here. Ask the manufacturer for the C1372 test report.
Freeze-thaw, which matters in central PA
Because ASTM C1372 requires freeze-thaw durability where saturated freezing happens, a block for a Pennsylvania wall should have it documented. CMHA lists three accepted routes:
- Method 1: proven field performance.
- Method 2: five specimens lose less than 1% of weight after 100 cycles (ASTM C1262).
- Method 3: at least four of five specimens lose less than 1.5% after 150 cycles (ASTM C1262).
CMHA says testing in water is considered sufficient for most applications, and saline testing may be considered where regular deicing-salt exposure is expected. It notes that ASTM has not adopted pass-fail criteria for saline testing.
What sits behind and under the units
CMHA’s guide gives these supporting details:
- Leveling pad: crushed stone or unreinforced concrete at least 6 in. thick, typically extending 6 in. beyond the toe and heel of the lowest unit. See trench and leveling pad.
- Drainage: gravel extending at least 12 in. behind the units, with a geotextile filter between the gravel and the soil in some cases. See drainage aggregate.
- Compaction: lifts of 8 in. or less; within 3 ft of the wall face, use only hand-operated or walk-behind equipment, preferably a vibrating plate of at least 250 lb (113 kg).
When it needs an engineer
CMHA says a qualified engineer should design the wall when there are surcharge loads, live loads, poor foundations or other special design conditions. It refers readers to each manufacturer’s product design information for the wall heights and conditions that require an engineer. Read when a segmental retaining wall needs an engineer, and check the permit rules for your township.
Related
All hardscape materials · Setting the first course · Geogrid placement
FAQ
How much does a retaining wall block weigh?
CMHA says SRW units generally weigh 30 to 100 lb (14 to 45 kg) each. Check the manufacturer’s data sheet for the exact unit.
Do segmental retaining wall blocks use mortar?
No. They are dry-stacked. CMHA says stability comes from mechanical interlock, friction or shear between units, and unit mass, with soil reinforcement added in reinforced soil walls.
What standard covers retaining wall blocks?
ASTM C1372 covers segmental retaining wall units, solid and hollow, and includes freeze-thaw durability where saturated freezing occurs.
When do I need an engineer for a block wall?
CMHA says a qualified engineer should design the wall where there are surcharge loads, live loads, poor foundations or other special design conditions.
Planning information only, not engineering advice. Wall design depends on soil, height and loads; follow the manufacturer’s instructions and a qualified engineer’s design where required. Sources checked Nov 23, 2026.