Skip to content Groundwork Design Co.Want a design?Custom patio, wall, deck and yard plans, drawn by builders. Anywhere in the U.S. From $349.Start here
LOCK HAVEN, PA · PA HIC #PA212584 · INSURED FREE ESTIMATES · CALL OR TEXT
PAGE

What Is a Riparian Buffer? PA Chapter 102 Width Rules and What Is Banned Inside

A riparian buffer is the vegetated area next to a stream, river, lake or other water body. Under 25 Pa. Code Section 102.14, earth disturbance that needs a Chapter 102 permit in an exceptional value or high quality watershed that is meeting its designated use may not occur within 150 feet of a perennial or intermittent stream, lake, pond or reservoir. The same section sets riparian forest buffer widths of 100 feet and 150 feet, and it has exemptions.

Riparian buffer and the terms around it

  • Riparian buffer: Penn State Extension describes it as the vegetated area next to streams, rivers, lakes and other water bodies.
  • Riparian forest buffer: under Section 102.14(b)(1), a riparian buffer made up mostly of native trees, shrubs and forbs that provides at least 60 percent uniform canopy cover.
  • Zone 1: the regulation calls for undisturbed native trees along the streambank.
  • Zone 2: managed native trees and shrubs beyond Zone 1.
  • Setback: a different but related idea, a required distance from a boundary or feature. See setback.

Why it matters on a job

Section 102.14 is a rule about earth disturbance, so it reaches grading, stripping and stockpiling near water. Inside the buffer, the regulation prohibits soil disturbance such as grading, topsoil stripping, plowing or cultivating. It also prohibits drainage by ditching, underdrains or other systems, housing or grazing animals for agricultural or commercial purposes, storing or stockpiling materials, and off-road vehicle travel. See topsoil stripping and spoil for those terms.

Pennsylvania width and scope rules

  • Scope: earth disturbance activities that need a Chapter 102 permit, in an exceptional value (EV) or high quality (HQ) watershed that is attaining its designated use. No earth disturbance within 150 feet of a perennial or intermittent river, stream, creek, lake, pond or reservoir, and any existing buffer must be protected.
  • Impaired EV or HQ waters: where waters fail one or more designated uses (Category 4 or 5 on the Integrated Water Quality report), the applicant must protect an existing riparian forest buffer, convert an existing buffer to one, or establish a new one.
  • Other waters: 100 feet total, made up of 50 feet in Zone 1 and 50 feet in Zone 2.
  • Special protection waters (HQ and EV): 150 feet total, with 50 feet in Zone 1 and 100 feet in Zone 2.
  • Measuring: widths run horizontally and perpendicular to the bank, with no more than a 10 percent shortfall below the minimum allowed under paragraph (c)(3).

What needs Department authorization, and what does not

Roads, bridges, trails, storm drainage, utilities and other structures, water obstructions or encroachments, and restoration projects are allowed in the buffer only with Department authorization. Without authorization, the regulation allows buffer maintenance (including vegetation disturbance and tree or shrub removal for natural succession and public safety), timber harvesting under the buffer management plan, passive or low-impact recreation that maintains the buffer’s function, emergency response, and research and data collection such as water quality monitoring.

Exemptions and waivers

Paragraph (d)(1) lists full exemptions. These include a project site more than 150 feet from the water, disturbance under 1 acre, no permit required, a permit or application dated before November 19, 2010, certain road maintenance, pipeline or utility repair and oil, gas, timber or mining activities with reclamation, a single-family home on a parcel acquired before November 19, 2010, and activities covered by another chapter’s setback requirements that are met. Paragraph (d)(2) lets the Department, or a conservation district after consulting it, waive buffer requirements for public health or safety abatement, linear projects, abandoned mine reclamation, temporary projects that are fully restored, redevelopment, or projects where compliance is infeasible due to site conditions or existing structures. The applicant must show reasonable alternatives and submit a written waiver request with the permit application. Paragraph (d)(4) allows offsite buffer protection or compensation to be proposed in a waiver request.

What Penn State Extension and DCNR add

A Penn State Extension video by natural resources educator Jodi Sulpizio recommends 30 to 100 feet on both sides of a waterway. It says buffers intercept sediment and filter runoff carrying fertilizers, pesticides, road salts and animal waste, and that a good, well-designed buffer can remove up to 80 percent of excess nutrients. It says forested buffers provide the greatest benefit, and that mowed grass does not prevent erosion. It states no zones and no species list. The Penn State figures are a recommendation, not a legal width.

The DCNR page describes riparian buffers as trees, shrubs and grasses planted along streams, a transition from land to water. It lists the DCNR Riparian Forest Buffer Grant Program and a multi-functional buffer concept with more flexibility in eligibility, design, width and species. It gives no recommended width, and it says Pennsylvania has more than 86,000 miles of rivers and streams.

Common mistakes

  • Stockpiling inside the buffer. Section 102.14(f)(1) prohibits storing or stockpiling materials there.
  • Mixing up a recommendation and a legal width. Penn State recommends 30 to 100 feet. The regulation sets 100 and 150 feet for riparian forest buffers.
  • Adding drainage into the buffer. Ditching and underdrains are prohibited there unless authorized as storm drainage.
  • Assuming the exemption applies. Exemptions depend on facts such as disturbance under 1 acre or a parcel acquired before a date, so confirm them.

What the sources do not say

The Penn State video states no date. The DCNR page states no recommended width, no grant amounts and no eligibility criteria. The PA DEP erosion and sediment control FAQ items give no buffer width. The regulation text here comes from Cornell’s Legal Information Institute copy, not the official Pennsylvania Code, so check the current text.

Riparian buffer FAQ

How wide is a riparian buffer in Pennsylvania?

Section 102.14 sets 100 feet total for other waters (50 feet Zone 1, 50 feet Zone 2) and 150 feet for special protection waters (50 feet Zone 1, 100 feet Zone 2).

Can you stockpile soil in a riparian buffer?

No, not where Section 102.14 applies. It prohibits storing or stockpiling materials in the buffer.

Does the rule apply to every project near a stream?

No. It covers earth disturbance needing a Chapter 102 permit, and it has exemptions such as disturbance under 1 acre and sites more than 150 feet from the water. A conservation district can confirm what applies.

What does Penn State recommend for buffer width?

A Penn State Extension video recommends 30 to 100 feet on both sides of a waterway. It does not state a minimum.

Sources

Verify widths and exemptions against the current source before you rely on them. This is planning information, not legal advice.

Keep reading

Planning work near a stream in central PA? Contact Muthler Landscaping & Construction for a straight answer. Planning information, not legal advice.