Power-operated hand tools: OSHA 1926.302

Quick answer: Section 1926.302 covers five kinds of power-operated hand tools: electric, pneumatic, fuel-powered, hydraulic and powder-actuated. Electric tools must be double-insulated or grounded, compressed air may not be used for cleaning unless reduced to less than 30 p.s.i. with chip guarding and PPE, fuel-powered tools must be stopped while being refueled, and powder-actuated tools may be run only by trained employees and must be tested each day before loading.

This page goes through 1926.302 paragraph by paragraph, as shown on OSHA’s website. Verify every number against the current CFR text at ecfr.gov before relying on it. The text covers electric, pneumatic, fuel, hydraulic and powder-actuated tools only and has no paragraph on jacks. For the wider subpart on hand and power tools, see our Subpart I overview. For power cords and GFCIs, see our job site electrical safety page.

Electric tools: paragraph (a)

Paragraph (a)(1) says electric power-operated tools must be either of the approved double-insulated type or grounded in accordance with subpart K. Paragraph (a)(2) says electric cords may not be used to hoist or lower tools.

Pneumatic tools: paragraph (b)

Paragraph (b) has the longest list:

ParagraphRule
(b)(1)Tools must be secured to the hose or whip by a positive means to prevent accidental disconnection
(b)(2)Safety clips or retainers must be installed and maintained on pneumatic impact tools to keep attachments from being expelled
(b)(3)Pneumatic nailers, staplers and similar tools with automatic fastener feed that operate above 100 p.s.i. at the tool need a muzzle safety device that prevents fastener ejection, unless the muzzle is in contact with the work surface
(b)(4)Compressed air may not be used for cleaning unless reduced to less than 30 p.s.i., and then only with effective chip guarding and PPE meeting subpart E; the 30 p.s.i. limit does not apply to concrete form, mill scale and similar cleaning
(b)(5)The manufacturer’s safe operating pressure may not be exceeded for hoses, pipes, valves, filters and other fittings
(b)(6)Hoses may not be used for hoisting or lowering tools
(b)(7)Hoses over 1/2-inch inside diameter need a safety device at the supply source or branch line to reduce pressure if the hose fails
(b)(8) and (b)(9)Airless spray guns operating at 1,000 p.s.i. or more need automatic or visible manual safety devices that prevent trigger pull until the device is manually released, or as an alternative a diffuser nut plus a nozzle tip guard, or other equivalent protection
(b)(10)Abrasive blast cleaning nozzles must have an operating valve that is held open manually, and a support on which the nozzle can be mounted when not in use

For blast cleaning exhaust and respirator rules, see our ventilation page for 1926.57.

Fuel-powered tools: paragraph (c)

Paragraph (c)(1) says fuel-powered tools must be stopped while being refueled, serviced or maintained, and fuel must be transported, handled and stored in accordance with subpart F. Paragraph (c)(2) says that when fuel-powered tools are used in enclosed spaces, the toxic gas concentration and PPE requirements of subparts D and E apply. Our flammable liquids storage page covers fuel storage and handling, and our confined space basics page covers enclosed work.

Hydraulic tools: paragraph (d)

Paragraph (d)(1) says the fluid used in hydraulic power tools must be fire-resistant, approved under Schedule 30 of the U.S. Bureau of Mines, and must retain its operating characteristics at the most extreme temperatures to which it will be exposed. Paragraph (d)(2) says the manufacturer’s safe operating pressures may not be exceeded for hoses, valves, pipes, filters and other fittings.

Powder-actuated tools: paragraph (e)

  • (e)(1) Operators: only employees trained in the operation of the particular tool in use may operate it.
  • (e)(2) Daily test: the tool must be tested each day before loading to confirm its safety devices work, using the manufacturer’s recommended method.
  • (e)(3) Defects: a tool not in proper working order, or that develops a defect during use, must be removed from service until properly repaired.
  • (e)(4) PPE: personal protective equipment must meet subpart E.
  • (e)(5) Loading and aiming: tools may not be loaded until just before firing. Loaded or empty tools may not be pointed at employees, and hands must stay clear of the open barrel end.
  • (e)(6) Unattended: loaded tools may not be left unattended.
  • (e)(7) Hard or brittle materials: fasteners may not be driven into very hard or brittle materials, including cast iron, glazed tile, surface-hardened steel, glass block, live rock, face brick or hollow tile.
  • (e)(8) Easily penetrated materials: driving into them should be avoided unless they are backed by a substance that prevents the fastener from passing through and becoming a flying missile.
  • (e)(9) Spalled areas: no fastener may be driven into a spalled area caused by an unsatisfactory fastening.
  • (e)(10) Atmosphere: tools may not be used in an explosive or flammable atmosphere.
  • (e)(11) Shields and guards: all tools must be used with the correct shield, guard or attachment recommended by the manufacturer.
  • (e)(12) Other standard: powder-actuated tools must also meet other applicable requirements of ANSI A10.3-1970.

The brittle-material list in (e)(7) names face brick and hollow tile, which are masonry materials.

Practical checklist

  • Use double-insulated or grounded electric tools, and never lower a tool by its cord or hose.
  • Secure pneumatic tools to the hose, keep safety clips on impact tools, and keep air pressure under the manufacturer’s limit.
  • Do not blow off dust or debris with compressed air at 30 p.s.i. or more.
  • Shut off fuel-powered tools before refueling or servicing.
  • Test powder-actuated tools each day before loading, and let only trained employees use them.
  • Keep hydraulic fluid within the fire-resistant specification in (d)(1).
Planning information only. This page summarizes public regulation text and is not engineering, legal or safety advice. Check the current CFR text before relying on any number here, and talk to a competent person about your own tools and site.

Sources

SourceUsed for
29 CFR 1926.302, Power-operated hand tools (OSHA)Paragraphs (a) through (e) summarized above

Checked Nov. 23, 2026. Check the current CFR text at ecfr.gov before relying on details.

Related

Hand and power tool safety (Subpart I) · Job site electrical safety · PPE criteria · All PA site work regulations

Talk to us about your project

FAQ

Can compressed air be used to clean dust off a work surface?

Paragraph (b)(4) says compressed air may not be used for cleaning unless reduced to less than 30 p.s.i., and then only with effective chip guarding and PPE meeting subpart E, with an exception for concrete form, mill scale and similar cleaning.

Who can use a powder-actuated tool?

Paragraph (e)(1) says only employees trained in the operation of the particular tool in use may operate it.

How often must a powder-actuated tool be tested?

Paragraph (e)(2) says each day before loading, to confirm the safety devices work, using the manufacturer’s recommended method.

What must electric power tools have?

Paragraph (a)(1) says they must be either the approved double-insulated type or grounded in accordance with subpart K.

General information only, not legal or safety advice. Employers must follow the current OSHA standard and applicable Pennsylvania rules. Source page checked Nov. 23, 2026.