Skip to content Groundwork Design Co.Want a design?Custom patio, wall, deck and yard plans, drawn by builders. Anywhere in the U.S. From $349.Start here
LOCK HAVEN, PA · PA HIC #PA212584 · INSURED FREE ESTIMATES · CALL OR TEXT
PAGE

Level Spreader: Turning Concentrated Runoff Into Sheet Flow

A level spreader is a flat, level outlet that lets concentrated runoff from a ditch or dike spread out and leave as a thin sheet across stable, vegetated ground. In Pennsylvania’s erosion and sediment control manual, the earthen version is meant for sediment-free runoff and has firm limits on flow, drainage area, length, grade and downstream cover.

Level spreader and the terms around it

  • Level spreader: according to the PA DEP manual, an outlet that releases sediment-free runoff as sheet flow down a stabilized slope. The manual describes earthen and structural types.
  • Sheet flow: runoff moving as a shallow, even layer instead of in a channel. See sheet flow.
  • Diversion ditch or dike: the channel that feeds the spreader. The manual says earthen spreaders are normally used where these outlet onto established vegetation.
  • Lip: the edge the water crosses. The manual describes a vegetated lip, which uses matting, and a rigid lip.
  • Vegetated swale: a related practice that carries water in a shallow channel. See vegetated swale.

Why it matters on a job

Runoff that has been gathered into a ditch moves faster and cuts deeper than the same water spread over a slope. When a ditch simply ends at the edge of a lawn or woods, the outlet can erode a gully. A level spreader is a way to end a ditch without that result, by giving the water a long, level edge to cross so it re-forms as sheet flow. It belongs on a site plan wherever a diversion needs a safe place to let go.

It is also easy to misuse. The manual is specific that an earthen level spreader is not for runoff that still carries sediment. It is not to be used below sediment traps, sediment basins or stormwater pipes. That limit matters because a spreader on a muddy discharge simply moves the sediment problem down the slope. Other outlets, such as a drain outlet or riprap apron, serve different situations.

Earthen level spreader limits in the DEP manual

Page 97 of the PA DEP Erosion and Sediment Pollution Control Program Manual (document 363-2134-008, effective April 15, 2000 in the copy cited below) gives these limits for earthen level spreaders:

  • Maximum discharge: 1 cubic foot per second for each foot of spreader length, based on the peak flow from a 10-year storm.
  • Maximum drainage area: 5 acres.
  • Length: 5 feet for each acre of drainage area, with a minimum of 5 feet and a maximum of 25 feet.
  • Width: at least 6 feet.
  • Grade: build the spreader on a zero percent grade. The last 20 feet of the feeding diversion channel should be 1 percent or less where possible.
  • Downstream distance: a maximum of 100 feet to a defined drainage way, on a slope of 5 percent or less unless site conditions are very uniform and stable.
  • Cover: the downstream grass slope needs at least 90 percent cover.
  • Foundation: it must be built on soil, not on fill.

The lip detail depends on flow and permanence. A rigid lip is required for design flows over 4 cubic feet per second or for permanent installations, and it must be entrenched at least 2 inches. A vegetated lip uses matting at least 4 feet wide, extending 6 inches over the lip, with the upstream edge buried at least 6 inches and staples at least 12 inches long. The manual lists structural level spreaders as a separate practice; this page does not cover its criteria. Verify every figure against the current manual and the approved plan.

How it connects to sheet flow and the plan

The manual describes the spreader’s output as sheet flow. Separately, in its calculation sections, it gives the maximum sheet flow length for unpaved areas in Pennsylvania as 150 feet, and it limits the downstream distance from an earthen spreader to a defined drainage way to 100 feet. The manual does not say one limit produces the other, so read them as two separate numbers. Our sheet flow entry covers the calculation side.

On a real project, a spreader is one detail in a larger erosion and sediment control plan, and the plan controls. Post-construction stormwater practices fall under the PCSM plan, which is a different document with different goals.

Level spreader FAQ

What does a level spreader do?

It releases sediment-free runoff from a diversion ditch or dike as sheet flow down a stabilized slope.

Can a level spreader be used below a sediment basin?

No. The PA DEP manual says earthen level spreaders are not to be used below sediment traps, sediment basins or stormwater pipes.

How large a drainage area can it serve?

The manual sets a maximum of 5 acres for an earthen level spreader, with a length of 5 feet per acre, a minimum of 5 feet and a maximum of 25 feet.

What grade should a level spreader be built on?

Zero percent, according to the manual, with the last 20 feet of the feeding channel at 1 percent or less where possible.

Sources

Descriptions here are summaries of the manual. Verify against the current source, which governs.