Vegetated Roof: What the PA Stormwater BMP Manual Says
Vegetated roof: how the PA BMP Manual describes it
Quick answer: In the Pennsylvania Stormwater Best Management Practices Manual, BMP 6.5.1 is a veneer of vegetation, 2 to 6 inches thick, on roofs under 30 degrees. It reduces runoff volume and slows flow but gives no recharge. The manual’s own water quality figures do not line up with its requirements.
What it is
The manual calls an extensive cover a veneer of vegetation 2 to 6 inches thick on a roof under 30 degrees, and calls covers 10 inches or deeper intensive roof gardens. The 6 to 10 inch range is left undefined. Variations are single media (pitched and light roofs, drought-tolerant plants, semi-rigid drain mat), dual media 4 to 6 inches thick for roofs up to 1.5:12, and dual media with a synthetic retention and detention layer, usually 5 inches or deeper, for roofs up to 1:12. Residential, commercial, ultra urban, industrial and retrofit uses are all rated Yes; highway and road use is None.
Key design numbers
| Item | What the manual says |
|---|---|
| Media depth | 2 to 6 inches |
| Media makeup | 85% to 97% non-organic, no clay-size particles, no more than 15% organic matter |
| Flashings | Extend 6 inches above the media surface |
| Internal drainage | Must handle a 2-year rainfall without surface runoff |
| Dead load | 8 to 36 psf |
| Live load | 2 inches of rain equals 10.4 psf (20 inches of snow gives the same load) |
| Root barrier | Thermoplastic membrane at least 30 mils thick |
| Slope stabilization | Needed on pitches over 2:12 |
Sedum and Delosperma are named as the standard groundcovers, and the manual notes Delosperma is deciduous in Pennsylvania. Stated performance is Medium/High volume reduction, no recharge, Low peak rate control and Medium water quality, with 85% for TSS and TP and 30% for nitrate.
How performance is figured
There is no simple formula. The manual says volume reduction needs continuous simulation using a local annual rainfall record, and it points to the German RWS program and European (FLL) guidelines for a volume table. Nutrient additions stop after establishment, about 18 months, and maximum pollutant removal takes about five years. Water quality covers should not be fertilized.
Construction and upkeep
The construction sequence runs 13 steps, from inspecting the waterproofing to protecting plants from wind, with no numeric values. Plan for 3 to 4 maintenance visits during establishment and then 2 visits a year, with more for irrigated assemblies. The manual puts basic maintenance at about 3 man-hours per 1,000 square feet per year. Any roof project also needs a structural review of the existing roof, which the manual’s load figures only frame.
Where the manual contradicts itself
- Mineral content: water quality media is required to be 100% mineral, but the key elements allow 85% to 97% non-organic and the specifications allow up to 15% organic matter.
- Irrigation: it is discouraged for these covers, yet dual media is called ideal with base irrigation and the construction sequence includes irrigation testing.
- Moisture capacity: 30% to 40% in one design consideration, but a 30% maximum water retention in the specification.
- Ratings: 85% TSS and TP is rated Medium here, while the same figures for constructed wetlands are rated High.
- Slope: the cover is allowed on roofs under 30 degrees, far steeper than the 2:12 point where stabilization is required.
- Old cost figures (2004): $8 to $15 per square foot installed. Treat as dated.
Pennsylvania approvals and who designs it
Roof structure, waterproofing and drainage need a qualified professional such as a licensed engineer or architect, and building permits apply. A vegetated roof counted as a stormwater control may need approval from your municipality, the county conservation district or DEP (see PA stormwater plan rules and Chapter 102). For ground-level infiltration options, see infiltration trench.
Sources
- Pennsylvania Department of Environmental Protection, Pennsylvania Stormwater Best Management Practices Manual (363-0300-002, December 30, 2006), BMP 6.5.1 Vegetated Roof, via the PA DEP eLibrary (greenport.pa.gov). Checked Nov 23, 2026.
Related
All drainage guides · Vegetated filter strip · Build a rain garden
FAQ
How thick is an extensive vegetated roof?
The PA BMP Manual describes extensive covers as 2 to 6 inches thick on roofs under 30 degrees.
How much does a green roof weigh?
The manual gives a dead load of 8 to 36 psf, plus a live load where 2 inches of rain equals 10.4 psf.
Does a vegetated roof recharge groundwater?
No. The manual lists recharge as None, with Medium/High volume reduction and Low peak rate control.
Does the manual allow irrigation?
It is inconsistent: irrigation is discouraged for BMP covers, yet dual media is called ideal with base irrigation.
Planning information only. Design must be done by a qualified professional and approved by your municipality and, where required, DEP. Source checked Nov 23, 2026.