Skip to content Groundwork Design Co.Want a design?Custom patio, wall, deck and yard plans, drawn by builders. Anywhere in the U.S. From $349.Start here
LOCK HAVEN, PA · PA HIC #PA212584 · INSURED FREE ESTIMATES · CALL OR TEXT
Home / Aggregates and Base Materials Guide / Open-graded vs dense-graded stone

Open-graded vs dense-graded stone

Nearly every aggregate decision comes down to one trade-off: stone with fines packs into a firm layer but drains slowly, and stone without fines drains freely but will not pack. Penn State and PennDOT both use the same vocabulary for it, and once you know the terms the product names stop being confusing.

The two types

Penn State’s Center for Dirt and Gravel Road Studies defines the two this way:

  • Open-graded (clean): porous, with noticeable air voids and little or no fines. It drains well but does not compact into a dense mass. Penn State lists it for base and subsurface drainage.
  • Well-graded (dense): dense, with few air voids. It does not drain well, but it is preferred where compaction matters, such as pipe bedding, fill and road surfaces.

Our glossary pages on gradation and fines cover the basic definitions.

What fines are and how they are measured

Fines are material smaller than the No. 200 sieve, about 0.003 inch, and Penn State says they are measured by washing the sample. PennDOT does the same: Publication 408 Section 703.2 requires the amount finer than the 75 micron (No. 200) sieve to be determined by washing under PTM No. 100 and caps it in Table D. The limits show where each stone sits:

Use in Pub 408 Table DMax. percent passing No. 200
Subbase, No. 2A10
Subbase, No. OGS5
Bituminous seal coat and surface treatment1.0 to 2.0
Cement concrete aggregate1
All other uses2

Where common stones fall

StoneTypeSource note
2ADense, well-gradedPenn State: 0 to 10% fines, listed for fine road base and surface
2B (No. 57)Open-graded, clean1-1/2 in. to about 3/32 in.
3A (No. 3)Open-graded, clean2-1/2 in. to 1/2 in.
1B (No. 8)Open-graded, clean1/2 in. to about 3/32 in.
OGSOpen-graded by spec5% max fines, uniformity test

Clay and plasticity

Fines are not all equal. Penn State notes that the plasticity index (PI) approximates clay content: a PI of 0 is non-plastic, its DSA material allows a PI of 0 to 4, and above about 6 the material behaves more like a cohesive soil, where clay can cause moisture problems and rutting. That is a reason to ask a supplier for a test, not just a name, when the stone will sit in a wet spot.

Choosing between them

  • Need a firm, flat layer that holds a load: dense-graded stone, compacted in layers. CMHA’s paver guidance calls for at least 4 inches compacted under patios and at least 6 inches under residential driveways on well-drained soil, with typical lifts of 4 to 6 inches under a 7,000 lbf plate compactor.
  • Need water to move through or away: open-graded clean stone, such as No. 57 around drain pipe. It will not compact tight, so do not expect it to behave as a base.
  • Not sure: your design or wall-block manufacturer’s instructions govern. See drainage aggregate behind a retaining wall for one example.

For how base is compacted, see how to compact a paver base.

Get a quote

FAQ

What does open-graded mean?

Penn State describes open-graded stone as porous, with noticeable air voids and little or no fines. It drains well but does not compact into a dense mass.

Is 2A open-graded?

No. It is well-graded stone with up to 10 percent fines for subbase, so it compacts tight and drains slowly.

How are fines measured?

By washing the sample over the No. 200 sieve; PennDOT specifies this as PTM No. 100 in Section 703.2.

Why does clay in fines matter?

Penn State says that above a plasticity index of about 6 the material behaves more like cohesive soil, and high clay can cause moisture problems and rutting.

Sources