PennDOT 2A subbase stone
2A is PennDOT’s dense-graded base stone: everything passes a 2-inch sieve, and enough small stone and fines are mixed in that it locks together when compacted. It is a PennDOT size, not an AASHTO number, and the state’s own subbase specification (Section 350) is the clearest statement of how it is meant to be used.
What 2A is
PennDOT Publication 408, Section 703.2, lists coarse aggregate sizes in Table C. Most rows are AASHTO numbers such as 57 and 8. Two rows are PennDOT’s own: 2A and OGS (open-graded subbase). Penn State’s Center for Dirt and Gravel Road Studies describes 2A as a well-graded stone with a 2-inch top size and roughly 0 to 10 percent fines, listed for fine road base and road surface. Because it contains fines, it compacts into a dense layer instead of staying loose and open.
The 2A gradation
Publication 408 Table C gives these total percent passing limits for No. 2A, and Table D limits the fines:
| Sieve | Percent passing |
|---|---|
| 2 in. (50 mm), top size | 100 |
| 3/4 in. (19.0 mm) | 52 to 100 |
| 3/8 in. (9.5 mm) | 36 to 70 |
| No. 4 (4.75 mm) | 24 to 50 |
| No. 8 (2.36 mm) | 16 to 38 (applies only to asphalt mixtures) |
| No. 16 (1.18 mm) | 10 to 30 |
| No. 200 (75 micron, fines) | 10 maximum when used as subbase (Table D) |
The sieve alignment above was read from the printed Table C and matches Penn State’s Aggregate 101 chart. The shape is what matters in the field: all of it is under 2 inches, roughly half or more is smaller than 3/8 inch, and up to 10 percent can be dust-size material. That spread is why a load of 2A from one quarry can feel different from another. Penn State also notes that the common yard name 2A modified is not an official specification; it usually means 2A with extra fines blended in. If a job depends on the exact material, ask the quarry whether it is PennDOT-certified and what its modified blend actually is.
How Section 350 builds a subbase
PennDOT’s Section 350 covers subbase under pavement. It is written for highways, but it shows what a well-built stone layer looks like:
- Material: Type S or better aggregate, No. 2A and/or No. OGS.
- Layer thickness: each 2A layer is at least 3 inches compacted, and layers are no more than 8 inches compacted.
- Compaction: roll to a condition of non-movement, working from the sides toward the center with uniform overlap.
- Fabric: where the plans call for it, a Class 4, Type A geotextile goes on the subgrade first, and equipment must not make sharp turns that tear or fold it.
- Depth check: a full-depth test hole at each density test location; a layer short by 1/2 inch or more is defective and gets reworked.
- Weather: a 2A subbase used as a haul road or exposed more than 60 calendar days must be re-checked, and it should not be left exposed through a winter shutdown.
Recycled concrete
Section 703.2 allows recycled concrete from Department, county or municipal projects to be used as 2A aggregate, but not in subbase. If a supplier offers recycled 2A, ask where it came from and whether it is meant for subbase use.
What this means for a patio or driveway base
A home project is not a PennDOT job, so Section 350 is a model and not a rule you must follow. For paver work, the Concrete Masonry and Hardscapes Association (CMHA) calls for a compacted aggregate base at least 4 inches thick under patios and walkways and at least 6 inches under residential driveways on well-drained soil, and says compacted lifts typically run 4 to 6 inches with a 7,000 lbf plate compactor. Wet, clayey or frost-prone ground calls for more base and a drainage path, so confirm depth with whoever designs or installs the job.
Related: how to compact a paver base · weight of a yard of 2A · PA gravel names and sizes · what is subbase
FAQ
Is 2A the same as crusher run?
They are close cousins. 2A is the PennDOT specification name for dense-graded stone with a 2-inch top size. Crusher run is a general trade term, so ask the quarry what gradation a given load actually meets.
How much fines can 2A have?
For subbase, Publication 408 Table D caps material passing the No. 200 sieve at 10 percent.
How thick can one layer of 2A be?
Section 350 allows layers no thicker than 8 inches compacted, with each 2A layer at least 3 inches compacted.
Can I use recycled concrete as 2A?
Publication 408 permits recycled concrete from public projects as 2A aggregate but not in subbase.
Sources
- PennDOT Publication 408/2020: Section 350 (Subbase) and Section 703.2, Tables C and D
- Penn State Center for Dirt and Gravel Road Studies, Aggregate 101
- CMHA, Construction of Interlocking Concrete Pavements (PAV-TEC-002)
Planning information only, not engineering advice. Publication 408 is a highway specification; a home project may need different thickness or materials. Confirm limits in the current edition. Sources checked Nov 23, 2026.