AASHTO No. 467, 5, 7 and 9 stone
Quick answer: Pub 408 Section 703.2 Table C lists No. 467, 5, 7 and 9 as coarse aggregate gradations, but the Penn State copy gives gradation bands only, with no nominal size ranges. What the sources do say clearly: No. 467 is one of four sizes allowed for Type A coarse aggregate in cement concrete, and a No. 7 plus No. 5 combination may substitute for No. 57.
Where these sizes show up
Most landscape and hardscape work uses No. 57, No. 67 or No. 8. The four sizes on this page are the ones that usually get skipped. Table C in Section 703.2 lists them next to the better-known numbers: 1, 3, 467, 5, 57, 67, 7, 8, 89, 9 and 10, plus 2A and OGS. This page draws on that table and the notes under it from the Penn State Aggregate Course Book 2022-23, which copies Pub 408/2020 Change No. 2. The sibling pages cover No. 57, No. 67 and No. 8 and No. 89.
What can and cannot be said about the gradations
Each of the four rows in Table C has five values, while the table has 15 sieve columns from 100 mm (4 inches) down to the 75 micrometer (No. 200) sieve. The values cannot be matched to sieves here. The values, in order, are:
| AASHTO No. | Values in order |
|---|---|
| 467 | 100, 95 to 100, 35 to 70, 10 to 30, 0 to 5 |
| 5 | 100, 90 to 100, 20 to 55, 0 to 10, 0 to 5 |
| 7 | 100, 90 to 100, 40 to 70, 0 to 15, 0 to 5 |
| 9 | 100, 85 to 100, 10 to 40, 0 to 10, 0 to 5 |
These are listed only to show what the document contains. Do not use them as sieve limits. Use the original Table C in Pub 408 if you need sieve-by-sieve numbers. The Course Book also gives no nominal size range for these four, and the Penn State Aggregate 101 bulletin has no entries for them either, so this page does not state sizes.
The No. 7 plus No. 5 substitution
A note under Table C says a combination of No. 7 and No. 5 may substitute for No. 57, subject to size-percentage limits. That fits what Aggregate 101 says about No. 57 (PA name 2B): it is a blend of AASHTO 5 and AASHTO 7. In practice that means a plant that stocks the two narrower sizes can build No. 57 from them, and a ticket reading No. 57 may in some cases be a blend. If a job depends on a specific No. 57 gradation, ask the supplier whether the load is straight No. 57 or a blend. Check Pub 408 for the limits attached to the substitution.
No. 467 and concrete
Section 704.1(b) lists the maximum aggregate sizes allowed for Type A coarse aggregate in cement concrete as No. 467, No. 57, No. 67 or No. 8. So of the four sizes on this page, only No. 467 appears in the concrete section, and No. 5, 7 and 9 do not. For how concrete classes are set, see cement concrete classes.
Fines limits that apply
Table D in Section 703.2 caps material passing the No. 200 sieve by the use the aggregate is put to.
| Use | Maximum passing No. 200 |
|---|---|
| Subbase, No. 2A | 10% |
| Subbase, No. OGS | 5% |
| Bituminous seal coat | 1.0% |
| Seal coat with precoated aggregate | 2.0% |
| Bituminous surface treatment | 1.0% |
| Cement concrete | 1% |
| All other uses | 2% |
The table lists no separate limit for No. 5, 7 or 9, so the heading that applies depends on the use. For concrete it is 1%, and for most other uses the all-other-uses 2%.
Sources and approval
A footnote says only Type C and Type S are listed in Bulletin 14, PennDOT’s list of approved sources. Section 703.5 covers acceptance, and our acceptance page explains certification and verification sampling.
Common mistakes
- Assigning the five numbers to specific sieves.
- Assuming No. 9 is a small version of No. 8 without checking the original table.
- Ordering No. 5 or No. 7 for concrete because No. 57 is allowed. Section 704.1(b) does not list them.
- Not asking whether a No. 57 load is a No. 7 and No. 5 blend.
Sources
- Penn State Aggregate Course Book 2022-23 (copies Pub 408/2020 Change No. 2, Sections 703 and 704). Checked Nov. 23, 2026.
- Penn State Center for Dirt and Gravel Roads Studies, Aggregate 101 technical bulletin (copyright 2020). Checked Nov. 23, 2026.
Related
All aggregates · AASHTO No. 57 · AASHTO No. 1 and 3 · Open vs dense graded
FAQ
Can No. 7 and No. 5 stone replace No. 57?
A note under Table C says a combination of No. 7 and No. 5 may be substituted for No. 57, subject to size-percentage limits.
Is No. 467 stone allowed in concrete?
Yes. Section 704.1(b) lists No. 467 among the maximum sizes for Type A coarse aggregate in cement concrete, alongside No. 57, No. 67 and No. 8.
What is the fines limit for these sizes?
Table D has no separate line for them. Cement concrete is limited to 1% passing the No. 200 sieve and all other uses to 2%.
Can you give the sieve percentages for No. 467, 5, 7 and 9?
Not reliably. Each row has five values against 15 sieve columns, so this page does not assign them to sieves.
Planning information only. The project specification and your engineer or inspector govern. Sources checked Nov. 23, 2026.