AASHTO No. 67 Stone: What Pub 408 Says, and What the Penn State Tables Skip

Home / Aggregates / AASHTO No. 67

AASHTO No. 67 stone

Quick answer: No. 67 is a coarse aggregate number in Pub 408 Table C and a named concrete stone size in Section 704.1(b). Penn State’s road-aggregate tables do not list it, and its gradation row did not read cleanly, so no sieve numbers are given.

Where No. 67 appears in Pub 408

AASHTO No. 67 is one of the coarse aggregate sizes in Pub 408, Section 703.2, Table C. As reproduced in the Penn State Aggregate Course Book 2022-23, that table lists the numbers 1, 3, 467, 5, 57, 67, 7, 8, 89, 9, 10, plus 2A and OGS. The row for 67 reads 100, 90 to 100, 20 to 55, 0 to 10, then 0 to 5. The sieve column headers in the text I could read are flattened, and the row has fewer values than there are sieve columns, so I cannot say which sieve each number belongs to. This page therefore gives no sieve-by-sieve gradation for No. 67. It also gives no nominal size range, because none of the pages I read states one for this number.

What the Penn State bulletins do not say

The Aggregate 101 bulletin and the DSA Handbook Appendix F, both from the Penn State Center for Dirt and Gravel Roads Studies, list common Pennsylvania aggregates, but neither lists No. 67. Aggregate 101 lists No. 57, which it pairs with the Pennsylvania name 2B at 1.5 inches down to 3/32 inch, clean. Appendix F lists No. 57 and No. 8. If a supplier quotes No. 67 and you only have those two Penn State tables, you will not find the stone there. That gap is why this page leans on the Pub 408 copy and says plainly where it stops. For the neighboring sizes, see AASHTO No. 57 stone and AASHTO No. 8 and No. 89.

The concrete connection in Section 704.1(b)

The one use of No. 67 that the text states directly is in cement concrete. Section 704.1(b), as copied in the Course Book, lists coarse aggregate for cement concrete as Type A, with a maximum size of AASHTO No. 467, No. 57, No. 67 or No. 8, in stone, gravel or slag under Section 703.2. So No. 67 is one of four named size choices for concrete coarse aggregate. The same section ties that aggregate to Type A quality, the type with the lowest soundness limit in Table B, which is why the quality limits below matter. For how concrete classes themselves are set up, see PennDOT cement concrete classes.

Fines and washing for No. 67

Table D in Section 703.2 caps the percent passing the No. 200 sieve by use. The readable limits are 1 percent for cement concrete under Section 704 and 2 percent for all other uses, with higher caps for subbase materials. Unlike No. 10, No. 67 is not named in the table’s washing-test exemption. Section 703.2(a)2 adds that gravel used in cement concrete must be washed thoroughly during production.

Quality type limits that apply

Section 703.2 sorts coarse aggregate into Types A, B, C and S. The Course Book copy of Table B gives these readable maximums: soundness of 10, 12, 20 and 16 percent; abrasion of 45, 45, 55 and 55 percent; and deleterious shale of 2, 2, 10 and 10 percent. Penn State’s Appendix F gives abrasion maximums of 40, 45 and 55 for Types A, B and C, so the two Penn State sources disagree on the Type A abrasion number, 40 versus 45. I have not resolved that, and the edition in your project documents controls. For gravel, Section 703.2(a)2 sets a maximum absorption of 3.0 percent for all Type A uses, except dredged river gravel in portland cement concrete, and 3.5 percent for Type B uses. More detail is on the quality types page.

Acceptance and certification

Section 703.5 covers acceptance of construction aggregates. Each day’s shipment is certified, producers submit an annual quality control plan, and stockpiles are sampled for source verification. Section 703.2(b) requires a PennDOT Certified Aggregate Technician to test coarse aggregate at the source according to Bulletin 14. A footnote to Table C says only Type C and Type S numbers are listed in Bulletin 14. In practice, if your job calls for No. 67 under a PennDOT-style spec, ask for the daily certification that matches the number on the ticket.

Sample weights and a related note

PTM 519, which is reprinted in the Course Book, groups the gradations “AASHTO #467, #5, #57, #67” together when it sets minimum sample weights for testing. The test method therefore sizes samples for No. 67 the same way it does for No. 57 and No. 467. A note to Table C also lets a combination of No. 7 and No. 57 substitute for No. 57 under limits on the proportion of No. 7. The note does not mention No. 67, so do not extend it to No. 67.

Pub 408 editions

Everything above about Table B, Table C, Table D and Section 704.1(b) comes from the Course Book’s copy of Pub 408/2020 Change No. 2. I did not read the 2016 or 2026 editions, so a number or a list of sizes could differ. The edition named in your bid documents controls.

Common mistakes

  • Quoting a sieve percentage for No. 67 from memory. The row is unreadable in the copy I read.
  • Assuming a Penn State road-aggregate table covers No. 67. It does not list it.
  • Applying the No. 7 and No. 57 substitution note to No. 67.
  • Using the Type A abrasion limit without checking which edition and which table you are reading.

Sources

Related

All aggregates · AASHTO No. 57 stone · AASHTO No. 8 and 89 · Concrete classes

Get a quote

FAQ

Is AASHTO No. 67 stone in Pub 408?

Yes. It is one of the numbers in Section 703.2, Table C, and it is named in Section 704.1(b) as a coarse aggregate size for cement concrete.

What size is No. 67 stone?

The sources I read do not state a size range for it, and the gradation row did not extract with readable sieve headers, so this page does not give one.

Do Penn State’s aggregate bulletins list No. 67?

No. Aggregate 101 lists No. 57 and Appendix F lists No. 57 and No. 8, but neither lists No. 67.

What fines limit applies to No. 67 in concrete?

Table D shows 1 percent passing the No. 200 sieve for cement concrete under Section 704. Confirm against the edition in your documents.