What Is Shoring in Excavation?
Shoring is a structure, such as a metal hydraulic, mechanical or timber system, that supports the sides of an excavation and helps prevent cave-ins.
Shoring versus a trench box
OSHA groups bracing, shoring and underpinning together as support systems. The key difference from a trench box is what each one does. Shoring pushes against the trench walls to hold the soil in place. A trench box, which OSHA calls a shield, does not hold the walls up. It stands between the wall and the workers so that if the wall fails, the people inside are protected.
When contractors use it
Shoring suits places where sloping would need more room than the site has, such as next to a building, a road or a property line. Systems are installed and removed under the direction of a competent person, and OSHA’s appendices to Subpart P give the design options. Deep or unusual excavations call for an engineer’s design.
Planning information only, not engineering, legal or safety advice. Confirm requirements with your engineer or the OSHA text.
How shoring is chosen and installed
Under OSHA 1926.652, a protective system for a support-type design must follow one of four routes: timber shoring built to Appendices A and C, aluminum hydraulic shoring used per the manufacturer’s tabulated data (or Appendix D if that data cannot be used), other written tabulated data that names the approving registered professional engineer, or a written design approved by a registered professional engineer. If you use manufacturer data, you follow all of the manufacturer’s specifications and limitations, and any deviation needs the manufacturer’s written approval. The paperwork stays on the jobsite while the work is under way.
Installation order matters. Support members must be connected securely so they cannot slide, fall or kick out, and no member may be loaded beyond its design capacity. When the supports come out, removal begins at the bottom of the excavation and works upward, members are released slowly while the crew watches for signs of failure, and backfilling keeps pace with the removal. In a trench you may dig up to 2 feet below the bottom of the support members only if the system is designed for the full trench depth and there are no signs of soil loss from behind or below the supports.
Common mistakes and limits
OSHA requires protection from cave-ins in every excavation, with two exceptions: excavations made entirely in stable rock, and excavations less than 5 feet deep where a competent person’s examination shows no potential for a cave-in. Next to a building or retaining wall, 1926.651(i) adds that you may not dig below the base or footing of a foundation or retaining wall where it could create a hazard unless a support system such as underpinning is provided, the excavation is in stable rock, or a registered professional engineer approves the work. Damaged equipment is another trap: a competent person must evaluate it, and if its capacity cannot be assured it comes out of service until an engineer approves it.
Related terms
See sloping and benching, the alternatives that need more room, and excavation for the OSHA definition.
Additional source: OSHA 1926.651, specific excavation requirements.
FAQ
Is shoring the same as a trench box?
No. Shoring supports the walls. A trench box shields the workers if a wall fails.
When is shoring a better choice than sloping?
When there is not enough room to cut the walls back, such as beside a structure or property line.
What is underpinning?
OSHA lists it with shoring and bracing as a support system. It strengthens or extends an existing foundation when digging next to it.
Sources
Related
Back to the full glossary. Related terms: Trench box and Protective system.
Questions about digging on your property? Contact Muthler Landscaping & Construction.