What Is ASTM C936? Paver Standard Defined
ASTM C936 is the standard specification for solid concrete interlocking paving units. It sets the quality requirements that concrete pavers should meet.
What ASTM C936 means
ASTM International publishes C936 as the specification for solid concrete interlocking pavers. It covers properties such as dimensions, compressive strength, water absorption and freeze-thaw durability, and it sets how units are tested. The standard is revised from time to time, so the figures below are from the 2021 edition and you should get the current edition from ASTM.
Where it comes up
It shows up in commercial and municipal specs, and on manufacturer data sheets as a compliance statement. Freeze-thaw durability matters in central PA winters, which is why this standard is worth asking about. See our pavers heaving in winter article.
In the field
Ask the supplier whether the product meets ASTM C936 and whether they can provide test reports. A unit that meets the standard still needs a sound base and edge restraint to perform.
Limits in the 2021 edition
- Size and shape: exposed face area of 101 square inches or less, length divided by thickness of 4 or less, and a minimum thickness of 2.36 inches (60 mm).
- Compressive strength: an average of at least 8,000 psi, with no single unit below 7,200 psi.
- Absorption: an average of 5 percent or less, with no unit above 7 percent.
- Freeze-thaw: for units exposed to freezing and deicers, show proven field performance or pass a lab test. In a 3 percent saline test for deicing service, average mass loss must not exceed 225 grams per square meter at 28 cycles or 500 at 49 cycles.
- Tolerances: length and width within 1.6 mm, and thickness within 3.2 mm.
Abrasion resistance is tested only when requested. Minor manufacturing cracks and minor handling chips are not grounds for rejection.
Testing and paperwork
The standard calls for at least three specimens each for strength and absorption, tested within 12 months before delivery, and at least three for freeze-thaw, tested within 24 months. A purchaser can inspect and sample at the plant. If a sample fails, the manufacturer may sort the lot, and a new sample from the remaining units is retested. So when you ask a supplier for test reports, check the dates as well as the results.
Common mistakes
- Assuming a thin unit qualifies. Units under 60 mm thick fall outside the size limits above.
- Ignoring the deicing condition. The freeze-thaw test differs for deicing service, so say so if salt will reach the surface.
- Expecting the paver standard to fix the base. It covers the unit only, and says nothing about base or sand.
Related terms: spall, bedding sand and interlock.
Source for this section: ASTM C936/C936M-21, as shown in a publicly available preview copy (iTeh Standards sample). Planning only, confirm with your local code office and the current edition.
Frequently asked questions
What does ASTM C936 cover?
Solid concrete interlocking paving units, including strength, absorption, durability and dimensional requirements.
Do all pavers meet it?
Not automatically. Ask the supplier for compliance or test data for the product.
Does it apply to retaining wall block?
No. Wall units have their own standard. This one is for interlocking paving units.
Sources
- ASTM C936: Standard Specification for Solid Concrete Interlocking Paving Units
- CMHA, PAV-TEC-001: Glossary of Terms for Segmental Concrete Pavement (2023)
Related
- Hardscape glossary
- Related terms: paver and frost heave
- Pavers heaving in winter
Planning a paver project in central PA? Contact Muthler Landscaping & Construction for a straight answer on products and base.