What Is Bedding Sand? Depth, Type and What Not to Use Under Pavers

Bedding sand is the thin, screeded layer of coarse washed sand that pavers are set on, between the compacted stone base and the pavers. It is a leveling layer, not structure. Pavers call for concrete sand meeting ASTM C33, screeded to about 1 inch.

What bedding sand does

Crushed stone cannot be graded perfectly smooth, and pavers are not perfectly uniform. The sand fills that gap so every paver sits flat and level. It also lets water drain down to the base. All the strength is in the base underneath, so the sand stays thin. For the full build, see how to build a paver patio.

Depth and type

Two industry documents define the material. CMHA’s PAV-TEC-002, the successor to the ICPI tech spec, names ASTM C33 as the standard for bedding sand under concrete pavers and calls that grade concrete sand. It sets an uncompacted nominal thickness of 1 inch. CMHA’s application guide, PAV-TEC-010, widens that to 1 to 1 1/2 inches as long as the thickness is consistent. Do not install frozen or saturated sand, and leave the layer undisturbed once it is screeded.

What not to use

  • Mason sand: CMHA warns against it because it can drain slowly and be unstable, and the sand layer has to pass water down to the base.
  • Stone dust and limestone screenings: CMHA says they often compact unevenly and can block lateral drainage. PAV-TEC-010 adds that they can carry too much material passing the No. 200 sieve.
  • A correction layer: bedding sand is not meant to even out the base. PAV-TEC-010 directs that depressions in the base be filled with base stone and compacted.

Bedding sand is also not joint sand. The sand that goes between pavers afterward is a separate product, covered in polymeric sand vs regular sand.

In the field

Because the layer is so thin, it is a small quantity. An inch of sand over 100 square feet is about 8.3 cubic feet, roughly a third of a cubic yard, before waste. It is also the one layer that cannot be bought and forgotten: once it is screeded, any disturbance means re-screeding that spot. How the sand is placed and protected during a job is covered step by step in how to build a paver patio.

Frequently asked questions

Is bedding sand the same as joint sand?

No. Bedding sand is the layer under the pavers. Joint sand is a separate product swept between the pavers afterward. The comparison is in polymeric sand vs regular sand.

What does ASTM C33 mean for bedding sand?

It is the ASTM standard that CMHA’s construction spec names for bedding sand under concrete pavers, and the spec calls this grade concrete sand. When you order, ask for sand meeting ASTM C33 rather than just asking for sand.

Is bedding sand part of the base?

No. It sits on top of the compacted stone base as a leveling layer and carries no structure. The strength is in the base underneath, which is why the sand stays thin. Base depth is covered in paver base depth.