Home / Compare / Stone dust vs concrete sand under pavers
Comparison · central PA
Stone dust vs concrete sand under pavers
The bedding layer is the thin cushion that pavers sit on, and crews and homeowners argue about what it should be made of. Stone dust, also sold as screenings, is cheap and common. Concrete sand is the material the paver industry names. The Concrete Masonry and Hardscapes Association (CMHA) and the Interlocking Concrete Pavement Institute (ICPI) are direct on this point, and neither of their documents mentions pea gravel at all.
Quick answer
For standard pavers, the sources favor concrete sand. CMHA specifies sharp, washed concrete sand meeting ASTM C33 at a nominal 1 inch before compaction, and lists masonry sand, limestone screenings and stone dust as materials not to use because they compact unevenly and can impede lateral moisture drainage. ICPI’s older guide says stone dust can contain too much fine material. No source in this comparison favors stone dust for bedding. Open-graded stone does appear in CMHA’s note, but only as the 2 inch bedding course for permeable pavers, not as a swap for sand under standard pavers.
Side by side
| Item | Concrete sand | Stone dust |
|---|---|---|
| CMHA position | The specified bedding material, ASTM C33, sharp and washed (CMHA) | Listed as a material not to use for bedding (CMHA) |
| Thickness | Nominal 1 in. uncompacted (CMHA); 1 to 1-1/2 in. screeded in the older ICPI guide | Not specified; not recommended |
| Behavior | Clean, sharp particles without foreign material (CMHA) | Often compacts unevenly and can impede lateral moisture drainage (CMHA) |
| Fines | Washed, so fines are limited (CMHA) | Can contain too much material passing the No. 200 sieve (ICPI) |
| Weather | Do not install frozen or saturated sand (CMHA) | Not covered |
| Permeable pavers | Not used; bedding is about 2 in. of open-graded ASTM No. 8 stone (CMHA) | Not used |
| Pea gravel | Not mentioned in the CMHA or ICPI documents | |
CMHA PAV-TEC-002-22 and PAV-TEC-018-22, ICPI Tech Spec 10 (1999, revised 2004), checked Nov 23, 2026. Verify against current sources and your supplier’s specifications.
What CMHA specifies for bedding
CMHA’s construction note (PAV-TEC-002) says the bedding layer is concrete sand meeting ASTM C33 or the Canadian equivalent, with sharp, washed particles and no foreign material, about 1 inch thick before it is compacted. Frozen or saturated sand should not be installed. The note names three materials not to use: masonry sand intended for mortar, limestone screenings, and stone dust, which it also calls waste screenings. It says these often compact unevenly and can impede lateral moisture drainage. The bedding sits on an aggregate base that CMHA wants at least 4 inches thick for pedestrian areas and at least 6 inches for residential driveways over well-drained soils, so a thin bedding layer cannot make up for a poor base. Our page on paver driveway requirements covers the layers below.
What ICPI’s older guide adds
ICPI’s Tech Spec 10 (1999, revised 2004) says to screed bedding sand to an even 1 to 1-1/2 inches, that the sand should meet ASTM C33, and that mason sand should not be used. It says stone dust or waste screenings should not be used as bedding sand because they can contain too much material passing the No. 200 sieve. It also says not to use bedding sand to fill low spots in the base; those should be filled with base material and compacted. It sets a base surface tolerance of plus or minus 3/8 inch over a 10 foot straightedge. Note that the thickness differs from CMHA’s more recent note, which gives a nominal 1 inch, so ask the installer which one the job follows and check the current documents. See our entries on the Proctor test for how base compaction is measured.
Joint sand and permeable systems are different
Do not confuse bedding with joint sand. CMHA says joint widths are 1/16 to 3/16 inch and that joint sand can be finer than bedding sand, meeting ASTM C144, though bedding sand can also be used with more effort. Stabilized joint sand is optional and may help in areas prone to sand loss; our comparison of polymeric sand and regular joint sand covers that choice. Permeable pavers use a different system. CMHA’s permeable note calls for about 2 inches of small open-graded angular stone, ASTM No. 8, as the bedding, with angular ASTM No. 8, 89 or 9 stone in the joints. Our page on open-graded vs dense-graded stone explains why that stone is not interchangeable with sand or screenings. The sources do not address rounded stone such as pea gravel in either system, so we cannot say how it performs.
When each one fails
- It is installed frozen or saturated, which CMHA says not to do.
- It is used to fill low spots in the base instead of base material.
- It is not clean, sharp and washed as specified.
- It compacts unevenly under the pavers.
- It impedes lateral moisture drainage.
- Excess fines are present, which ICPI flags as a concern.
- The base underneath is thin or poorly compacted.
- Moisture cannot drain from the bedding layer.
- The paver edges have no restraint holding the units.
Related
Compare pavers vs flagstone patio and permeable vs standard pavers.
Questions
Can I use stone dust under pavers?
CMHA lists stone dust, also called waste screenings, as a material not to use for bedding sand because it often compacts unevenly and can impede lateral moisture drainage. ICPI’s older guide gives a similar warning about fines.
How thick should the paver bedding layer be?
CMHA says a nominal 1 inch of concrete sand before compaction. ICPI’s older guide says to screed 1 to 1-1/2 inches. Confirm with your installer and the current CMHA note.
Can I use pea gravel as bedding?
The CMHA and ICPI documents do not mention pea gravel, so we cannot say. CMHA’s only stone bedding is 2 inches of open-graded angular ASTM No. 8 stone for permeable pavers. Ask your paver manufacturer or installer.
What is the difference between bedding sand and joint sand?
Bedding sand is the cushion under the pavers, specified as concrete sand. Joint sand fills the gaps between pavers, can be finer and should meet ASTM C144 according to CMHA, and bedding sand can also be used for joints with more effort.
Sources
Checked Nov 23, 2026. Verify against the current source. Planning information, not an engineering design. Muthler Landscaping & Construction LLC · 913 Bellefonte Ave, Lock Haven, PA 17745 · (570) 397-9800 · PA HIC #PA212584.