Skip to content Groundwork Design Co.Want a design?Custom patio, wall, deck and yard plans, drawn by builders. Anywhere in the U.S. From $349.Start here
LOCK HAVEN, PA · PA HIC #PA212584 · INSURED FREE ESTIMATES · CALL OR TEXT
Home / Winter Guides: Snow, Ice and Cold-Weather Damage / Freeze-thaw damage to concrete

Freeze-thaw damage to concrete: how it happens and what prevents it

Short answer: concrete is damaged when the water in its pores is nearly saturated and freezes, because ice takes up about 9% more volume than water. Entrained air bubbles give that water room to move, and a low water-to-cement ratio keeps less water in the slab to begin with. De-icers make scaling worse, and young concrete is the most vulnerable.

The mechanism

The Federal Highway Administration (FHWA) explains that water in concrete’s capillary pores freezes and expands in cold weather. Concrete is at risk when it is critically saturated, above about 91.7%. Ice expands about 9% by volume, building pressure inside the hardened concrete, and cracking occurs if that pressure exceeds the tensile strength of the paste. For how many freeze-thaw cycles your area sees, see our freeze-thaw cycles by state and ZIP page.

Why air entrainment works

Entrained air consists of spherical bubbles between 0.0004 and 0.04 in. (0.01 and 1 mm) across, added on purpose with an admixture. FHWA says well-distributed bubbles shorten the distance water has to travel to reach an empty void, which relieves the pressure. Entrapped voids, the irregular ones larger than 1 mm that every mix has, are less useful. The National Ready Mixed Concrete Association (NRMCA) says to use air-entrained concrete wherever it will be wet and exposed to freezing and thawing. There is a cost: each 1% increase in air content reduces 28-day compressive strength by about 3 to 5%, per FHWA, so the air content is controlled within a range, not maximized. FHWA’s pavement resource does not give a target range or spacing factor, so ask your supplier for the specified air content. See air-entrained concrete.

Protection thresholds for young concrete

MilestoneWhat it means (NRMCA CIP 27)
About 25°FFresh concrete can freeze
500 psi (about two days)Protect from freezing until it reaches this; frozen earlier it can lose more than 50% of its potential strength and will not be durable
3,500 psiProtect new concrete from freeze-thaw cycles until it reaches this
28 daysTypical design strength; PACA says keep concrete above freezing until it gets there

These are two different thresholds in the NRMCA publication: 500 psi for protection from freezing, and 3,500 psi for protection from freeze-thaw cycles. See how cold is too cold to pour concrete.

Scaling, de-icers and the first winter

The Pennsylvania Aggregates and Concrete Association (PACA) describes scaling as a surface condition common in the Northeast, where the paste can be easily picked off while the aggregate stays bonded. It often appears in spring, caused by freeze-thaw in a moist environment that de-icers amplify, by de-icers on concrete that has not fully cured, by overworking plastic concrete, by finishing while bleed water is still visible, by adding water to the surface during finishing and by poor curing. PACA generally recommends no de-icers in the first year of a pavement’s life, and says never to use ammonium sulfate or ammonium nitrate. See concrete spalling for repair options and de-icer types compared.

The mix choices that help

  • Water-to-cement ratio: for Northeast conditions, ACI 332 recommends a maximum of 0.45 for exterior pavements, curbs and sidewalks, per PACA.
  • Curing: durability depends on how well the concrete is cured. In freezing weather NRMCA says to avoid water curing and to use a membrane-forming compound or paper or plastic sheets on slabs.
  • Sealers: PACA says sealers or curing membranes keep moisture in the concrete so it can keep gaining strength, and help block chloride-laden moisture.
  • Finishing: do not finish while bleed water is on the surface, and do not add water to the surface.

Sources: FHWA, HIF-20-085 concrete pavement resource; NRMCA, Cold Weather Concreting (CIP 27); PACA, Scaling information sheet. Checked Nov 23, 2026.

Get a quote

FAQ

What causes freeze-thaw damage in concrete?

Water in the capillary pores freezes and expands about 9%. FHWA says concrete is at risk when critically saturated, above about 91.7%, and cracks if the pressure exceeds the tensile strength of the paste.

Does air-entrained concrete weaken the slab?

Slightly. FHWA says each 1% increase in air content reduces 28-day compressive strength by about 3 to 5%, so air is held within a controlled range.

When can new concrete survive repeated freeze-thaw?

NRMCA says to protect new concrete from freeze-thaw cycles until it reaches 3,500 psi. Protection from a single freeze, to 500 psi, takes about two days.

Should I salt a new driveway in its first winter?

PACA generally recommends no de-icers in the first year of a pavement’s life and says not to use them on concrete that has not fully cured.

Planning information only, not engineering advice. Mix design, weather and site conditions vary; follow your contractor’s and supplier’s specifications. Sources checked Nov 23, 2026.