Site Lighting and Debris Disposal: OSHA 1926.56 Illumination Levels and 1926.252 Chutes, Scrap Removal and Flammable Waste
Site lighting and debris disposal: OSHA 1926.56 and 1926.252
Quick answer: Section 1926.56 sets minimum lighting levels for construction areas while any work is in progress, and section 1926.252 sets rules for getting debris off the job. General construction areas, excavation and waste areas, access ways and active storage areas need at least 3 foot-candles, material falling more than 20 feet outside the building walls must go down an enclosed chute, scrap and rubbish must be cleared as work progresses, and solvent waste and oily rags must stay in covered, fire-resistant containers until they leave the site.
This page goes through both sections as shown on OSHA’s website. Verify every number against the current CFR text at ecfr.gov before relying on it. The first section is in Subpart D of Part 1926, which covers occupational health and environmental controls. For related duties, see our general safety duties and housekeeping page and our fire prevention and storage page.
What 1926.56(a) requires
Paragraph (a) says construction areas, ramps, runways, corridors, offices, shops and storage areas must be lighted to not less than the minimum illumination intensities listed in Table D-3 while any work is in progress. The unit is the foot-candle, a measure of light intensity at the work surface. Table D-3:
| Foot-candles | Area or operation |
|---|---|
| 3 | General construction areas, concrete placement, excavation and waste areas, access ways, active storage areas, loading platforms, refueling and field maintenance areas |
| 5 | General construction area lighting; indoors, warehouses, corridors, hallways and exitways |
| 5 | Tunnels, shafts and general underground work areas, with a minimum of 10 foot-candles at the tunnel and shaft heading during drilling, mucking and scaling |
| 10 | General construction plants and shops, such as batch plants, screening plants, mechanical and electrical equipment rooms, carpenter shops, rigging lofts and active storerooms, mess halls, and indoor toilets and workrooms |
| 30 | First aid stations, infirmaries and offices |
Table D-3 lists both a 5 foot-candle row for general construction area lighting and a 3 foot-candle row that includes excavation and waste areas, access ways and active storage areas. Read the table in the current CFR text before choosing a lighting level for a given area. Paragraph (b) says that for areas or operations not covered by paragraph (a) or Table D-3, the standard refers to American National Standard A11.1-1965, R1970, Practice for Industrial Lighting, for recommended illumination values.
The rule in paragraph (a) applies while any work is in progress. The table names excavation and waste areas, refueling areas and field maintenance areas directly. Our excavation requirements page covers the other rules for excavations.
What 1926.252 requires
- (a) Enclosed chutes: where materials fall more than 20 feet to a point outside the building’s exterior walls, the drop must use a chute made of wood or an equivalent material. The chute must be closed on all sides and carry material from a higher point to a lower one.
- (b) Debris dropped through floor holes: if debris falls through floor openings without a chute, the landing area must be fully enclosed by barricades at least 42 inches high and at least 6 feet back from the edge of the opening above. Hazard warning signs must be posted at each level, and removal is not permitted in the lower area until debris handling ceases above.
- (c) Scrap and rubbish: scrap lumber, waste material and rubbish must be cleared from the immediate work area as work progresses.
- (d) Burning waste: any disposal of waste or debris by burning must follow local fire regulations.
- (e) Flammable waste: solvent waste, oily rags and flammable liquids must be kept in covered, fire-resistant containers until they are removed from the worksite.
Numbers and actions in the text
Each rule in 1926.252 ties to a number or an action: 20 feet for chutes, 42 inches and 6 feet for the barricade around a debris drop, and covered, fire-resistant containers for solvent waste and oily rags. Neither section sets a schedule for how often debris must be hauled away. Paragraph 1926.252(c) says only that scrap and rubbish are cleared as work progresses.
For burning, the section does not itself give a permitted or prohibited list. It points to local fire regulations, so check with the municipality and the fire authority that covers the job. Our flammable liquids storage page covers storage and handling of flammable liquids.
Practical checklist
- Find the Table D-3 level for each area you work in and check the light before work starts.
- Use an enclosed chute, closed on all sides, for debris that falls more than 20 feet outside the building walls.
- Where debris drops through floor openings with no chute, barricade the landing area at least 42 inches high and 6 feet back, and post warning signs at each level.
- Clear scrap lumber and rubbish from the immediate work area as work goes on.
- Check local fire regulations before burning anything.
- Keep solvent waste, oily rags and flammable liquids in covered, fire-resistant containers until they are hauled off.
Sources
| Source | Used for |
|---|---|
| 29 CFR 1926.56, Illumination (OSHA) | Paragraphs (a) and (b) and Table D-3 |
| 29 CFR 1926.252, Disposal of waste materials (OSHA) | Paragraphs (a) through (e) |
Checked Nov. 23, 2026. Check the current CFR text at ecfr.gov before relying on details.
Related
General safety duties and housekeeping · Fire prevention and storage · Flammable liquids storage · All PA site work regulations
FAQ
How much light does OSHA require in an excavation area?
Table D-3 in 1926.56 lists excavation and waste areas in the 3 foot-candle row. Check the table in the current CFR text.
When is a debris chute required?
Paragraph 1926.252(a) says where materials fall more than 20 feet to a point outside the building’s exterior walls, a chute made of wood or an equivalent material, closed on all sides, must be used.
How must oily rags and solvent waste be stored?
Paragraph 1926.252(e) says solvent waste, oily rags and flammable liquids must be kept in covered, fire-resistant containers until removed from the worksite.
Can debris be burned on site?
Paragraph 1926.252(d) says any disposal of waste or debris by burning must follow local fire regulations.
General information only, not legal or safety advice. Employers must follow the current OSHA standard and applicable Pennsylvania rules. Source pages checked Nov. 23, 2026.