Gases, vapors, fumes, dusts and mists: OSHA 1926.55
Quick answer: Section 1926.55 is the OSHA construction rule that sets exposure limits for airborne substances. Employers must limit employee exposure to any substance listed in its Table 1 or Table 2, ceiling values may never be exceeded, other limits are 8-hour time-weighted averages, administrative or engineering controls come first when feasible, and any respirator use must comply with 1926.103. Asbestos-type dusts and formaldehyde are carved out to their own sections.
This page goes through 1926.55 as shown on OSHA’s website. Verify every number against the current CFR text at ecfr.gov before relying on it. The section has paragraphs (a) through (d), two tables and footnotes. This page shows selected table entries and footnotes as examples and does not replace the full tables. The ventilation standard at 1926.57 points back to this section for its limits; see our 1926.57 ventilation page.
Exposure limits: paragraph (a)
Paragraph (a) says employers must limit employee exposure to any substance listed in Table 1 or Table 2. Two kinds of limit apply:
- (a)(1) Ceiling values: for Table 1 substances with a limit preceded by the letter C, exposure, measured from breathing-zone air samples, must at no time exceed the specified limit. If instantaneous monitoring is not feasible, the employer must assess the ceiling as a 15-minute time-weighted average that cannot be exceeded at any time during the working day.
- (a)(2) Other substances: for substances without the C designation, exposure must not exceed the limit as an 8-hour time-weighted average in any work shift.
Controls and protective measures: paragraph (b)
Paragraph (b) sets an order of preference. Administrative or engineering controls must be implemented first whenever feasible. If full compliance through those controls is not feasible, protective equipment or other protective measures must be used to keep exposure within the limits. Any equipment or technical measures must first be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use must comply with 1926.103. For the respirator side, see our PPE criteria and respiratory protection page.
Asbestos and formaldehyde: paragraphs (c) and (d)
Paragraph (c) says paragraphs (a) and (b) do not apply to airborne asbestos, tremolite, anthophyllite or actinolite dust. Where employees are exposed to these, 1926.1101 applies. Our asbestos in construction page covers that section. Paragraph (d) says paragraphs (a) and (b) do not apply to formaldehyde, and where employees are exposed to it, 1910.1048 applies.
What the two tables contain
Table 1 lists each substance with its CAS number, a limit in parts per million, a limit in milligrams per cubic meter and a skin designation. An X in the skin column indicates a dermal hazard. Examples:
| Substance in Table 1 | Limit shown |
|---|---|
| Acetone | 1000 ppm, 2400 mg/m3 |
| Ammonia | 50 ppm, 35 mg/m3 |
| Carbon monoxide | 50 ppm, 55 mg/m3 |
| Hydrogen sulfide | 10 ppm, 15 mg/m3 |
| Chloroform | Ceiling of 50 ppm, 240 mg/m3 |
Table 2 covers mineral dusts, with limits in million particles per cubic foot of air (mppcf). Examples:
| Dust in Table 2 | Limit shown (mppcf) |
|---|---|
| Crystalline silica | 250 |
| Quartz | Calculated by formula from the percent of SiO2 |
| Amorphous silica, including natural diatomaceous earth | 20 |
| Mica | 20 |
| Portland cement | 50 |
| Talc, non-asbestiform | 20 |
| Natural graphite | 15 |
| Inert or nuisance particulates | 50 mppcf, or 15 mg/m3 if smaller, for total dust with less than 1% SiO2 |
The table notes give a conversion factor: mppcf times 35.3 equals million particles per cubic meter. For the separate silica rule that applies to cutting pavers and concrete, see our silica rule page, which covers 1926.1153. Check the current text of both 1926.55 and 1926.1153 before relying on either table.
Selected footnotes
- Footnote E: designates simple asphyxiants. The limiting factor is available oxygen, which must be at least 19.5%.
- Footnote A3: refers to gasoline and petroleum distillates, whose composition varies, so the benzene and aromatic content should be determined to arrive at the appropriate limit.
- Footnote 3: directs use of the asbestos limit in 1926.1101.
Practical checklist
- Look up the substance in Table 1 or Table 2 of the current text and note whether it carries a ceiling designation.
- For ceiling values, treat the limit as one that may never be exceeded, and ask how it will be monitored.
- Use administrative or engineering controls first when feasible, before relying on protective equipment.
- Get any equipment or technical measure approved for the particular use by a competent industrial hygienist or other technically qualified person.
- Follow 1926.103 whenever respirators are used.
- Use 1926.1101 for asbestos-type dusts and 1910.1048 for formaldehyde, not this section.
Sources
| Source | Used for |
|---|---|
| 29 CFR 1926.55, Gases, vapors, fumes, dusts, and mists (OSHA) | Paragraphs (a) through (d), selected table entries and footnotes |
Checked Nov. 23, 2026. Check the current CFR text at ecfr.gov before relying on details.
Related
Ventilation (1926.57) · Silica rule · Asbestos in construction · All PA site work regulations
FAQ
What is a ceiling value in 1926.55?
Paragraph (a)(1) says for substances with a limit preceded by C, exposure measured from breathing-zone samples must at no time exceed the limit, and if instantaneous monitoring is not feasible it is assessed as a 15-minute time-weighted average.
What is the limit for substances without a ceiling?
Paragraph (a)(2) says exposure must not exceed the listed limit as an 8-hour time-weighted average in any work shift.
Do respirators replace engineering controls under 1926.55?
Paragraph (b) says administrative or engineering controls must be implemented first whenever feasible, and protective equipment is used when full compliance through those controls is not feasible.
Does 1926.55 cover asbestos?
Paragraph (c) says paragraphs (a) and (b) do not apply to airborne asbestos, tremolite, anthophyllite or actinolite dust, and 1926.1101 applies instead.
General information only, not legal or safety advice. Employers must follow the current OSHA standard and applicable Pennsylvania rules. Source page checked Nov. 23, 2026.