Skip to content Groundwork Design Co.Want a design?Custom patio, wall, deck and yard plans, drawn by builders. Anywhere in the U.S. From $349.Start here
LOCK HAVEN, PA · PA HIC #PA212584 · INSURED FREE ESTIMATES · CALL OR TEXT
PAGE
Home / PA site regulations / Asbestos in construction, 1926.1101

OSHA construction safety

Asbestos in construction: what OSHA 1926.1101 means for renovation and demolition

Quick answer: OSHA’s construction asbestos standard, 29 CFR 1926.1101, limits exposure to 0.1 fiber per cubic centimeter as an 8-hour average and 1.0 fiber per cubic centimeter over 30 minutes. It sorts work into Classes I through IV, treats certain older building materials as asbestos until proven otherwise, and requires a competent person to supervise.

What the standard covers

Section 1926.1101 applies to asbestos exposure in all construction work. The scope lists demolition or salvage of structures containing asbestos, removal or encapsulation of asbestos-containing material, construction, alteration, repair, maintenance or renovation of structures that contain it, installation of asbestos products, emergency cleanup of spills, and transport, disposal, storage and housekeeping connected to that work. Asbestos-containing asphalt roof coatings, cements and mastics are excluded. For a contractor doing interior demolition, siding or window replacement, flooring removal or work on older mechanical rooms, the standard decides what you must find out before the first cut.

Key definitions

  • Asbestos: chrysotile, amosite, crocidolite, tremolite, anthophyllite, actinolite and their chemically treated or altered forms, and it includes presumed asbestos-containing material.
  • ACM: material containing more than 1 percent asbestos.
  • PACM: presumed asbestos-containing material, meaning thermal system insulation and surfacing material found in buildings constructed no later than 1980. The presumption can be rebutted under paragraph (k)(5).
  • Competent person: someone who can identify asbestos hazards, select controls and has authority to correct them, with training that depends on the class of work. Class I and II work needs EPA Model Accreditation Plan supervisor training or equivalent.
  • Regulated area: the area where Class I, II or III work takes place, plus adjoining areas where debris accumulates, and any area where airborne asbestos exceeds or may reasonably exceed the limits.

Exposure limits

LimitValue
Permissible exposure limit, (c)(1)0.1 fiber per cubic centimeter, 8-hour time-weighted average
Excursion limit, (c)(2)1.0 fiber per cubic centimeter averaged over 30 minutes

The four classes of work

ClassWhat it covers
Class IRemoval of thermal system insulation and surfacing ACM and PACM, the highest-hazard category
Class IIRemoval of ACM that is not insulation or surfacing material, such as wallboard, floor tile and sheeting, roofing and siding shingles, and construction mastics
Class IIIRepair and maintenance work where ACM or PACM is likely to be disturbed
Class IVMaintenance and custodial work that touches but does not disturb ACM or PACM, and cleanup of dust and debris from Class I to III work

Class II is the one most likely to reach a home improvement contractor, since it covers flooring, roofing, siding shingles and similar materials. Training for Class II work on roofing, flooring, siding, ceiling tiles or transite must include category-specific practices and hands-on training, with at least 8 hours as the training text describes.

Find out before you disturb: identification duties

The standard says thermal system insulation and sprayed or troweled-on surfacing material in buildings built no later than 1980 are treated as asbestos-containing, and asphalt and vinyl flooring installed no later than 1980 is also presumed ACM. Building owners must determine the presence, location and quantity of ACM and PACM before work begins and tell prospective employers, other contractors and tenants. An employer who finds suspect material not previously identified must report it within 24 hours. A presumption is rebutted only through an AHERA inspection or bulk sample testing by an accredited inspector, or, for flooring, clearance by an industrial hygienist. Within 10 days after finishing work, employers report any remaining ACM or PACM and final monitoring results.

Prohibited practices and basic controls

  • No abrasive disc saws without point-of-cut ventilation or a HEPA-filtered enclosure.
  • No compressed air unless used with an enclosed capture system.
  • No dry sweeping, shoveling or other dry cleanup.
  • No employee rotation to reduce exposure.
  • Use HEPA vacuums, wet methods and prompt cleanup in leak-tight containers for all operations.
  • No eating, drinking, smoking or applying cosmetics in regulated areas.

All Class I, II and III work must happen in regulated areas supervised by a competent person, with the area marked and entry limited to authorized people. Warning signs read “DANGER / ASBESTOS / MAY CAUSE CANCER / CAUSES DAMAGE TO LUNGS / AUTHORIZED PERSONNEL ONLY.”

Exposure assessment, respirators and clothing

A competent person must assess expected exposures before or at the start of the job, and for Class I work the employer must presume exposure above the limits until monitoring or a negative exposure assessment shows otherwise. Daily monitoring applies to Class I and II workers in regulated areas unless a negative assessment exists. Respirators are required for Class I work, for Class II work when the material is not removed intact, for Class II and III work without wet methods or a negative assessment, and in emergencies. Filtering facepiece respirators may not be used for asbestos, and air-purifying respirators need HEPA filters. Protective coveralls, head and foot coverings and gloves are required where exposure exceeds the limits or no negative assessment exists.

Multi-employer sites

A contractor who creates a regulated area must tell other employers on site. The contractor who creates or controls an asbestos hazard must fix it, and the general contractor is treated as having general supervisory authority and must make sure the asbestos contractor complies. This matters for small subcontractors who share a site with demolition or abatement.

Planning information, not engineering or legal advice. Medical surveillance, recordkeeping and the rest of the training rules are not covered here. Asbestos work needs a competent person and, for abatement, a qualified contractor. Check the current CFR text and Pennsylvania requirements before starting.

Sources

Sources checked Nov. 23, 2026.

Related

Lead in construction, 1926.62 · Silica rule · Hazard communication · All PA site work regulations

Talk to us about your project

FAQ

What are the OSHA asbestos exposure limits in construction?

Section 1926.1101 sets a permissible exposure limit of 0.1 fiber per cubic centimeter as an 8-hour average and an excursion limit of 1.0 fiber per cubic centimeter over 30 minutes.

What materials are presumed to contain asbestos?

Thermal system insulation and surfacing material in buildings built no later than 1980, and asphalt or vinyl flooring installed no later than 1980, are presumed asbestos-containing until shown otherwise.

What is Class II asbestos work?

Class II is removal of ACM that is not insulation or surfacing material, such as wallboard, floor tile and sheeting, roofing and siding shingles, and construction mastics.

Can asbestos debris be dry swept?

No. The standard prohibits dry sweeping, shoveling or other dry cleanup, and requires HEPA vacuums, wet methods and leak-tight waste containers.

General information only, not legal or safety advice. Employers must follow the current OSHA standard and applicable Pennsylvania rules. Muthler Landscaping & Construction LLC, 913 Bellefonte Ave, Lock Haven, PA 17745, (570) 397-9800, PA HIC #PA212584. Source pages checked Nov. 23, 2026.