Skip to content Groundwork Design Co.Want a design?Custom patio, wall, deck and yard plans, drawn by builders. Anywhere in the U.S. From $349.Start here
LOCK HAVEN, PA · PA HIC #PA212584 · INSURED FREE ESTIMATES · CALL OR TEXT
PAGE
Home / PA site regulations / Equipment and site clearing (1926.600 and 1926.604)

Equipment and site clearing: OSHA 1926.600 and 1926.604

Quick answer: Section 1926.600 sets general rules for construction equipment, and section 1926.604 adds rules for site clearing. Unattended equipment near highways or active work areas needs lights, reflectors or barricades, parked equipment needs its parking brake set and wheels chocked on an incline, raised blades and buckets must be lowered or blocked, and site clearing crews must be protected from irritant and toxic plants and trained in first aid for them.

This page goes through both sections of the OSHA regulation text. Verify every number against the current CFR text at ecfr.gov before relying on it. Our pages on struck-by and backing hazards and rollover protection and seat belts cover neighboring rules for the same machines.

Lights, tires and blocking: 1926.600(a)(1) to (a)(3)

  • (a)(1) Unattended equipment: equipment left unattended at night, adjacent to a highway in normal use, or adjacent to active construction areas must have appropriate lights or reflectors, or barricades with appropriate lights or reflectors, to identify its location.
  • (a)(2) Tires: a safety tire rack, cage or equivalent protection must be provided and used when inflating, mounting or dismounting tires on split rims or on rims with locking rings or similar devices.
  • (a)(3)(i) Equipment held aloft: heavy machinery or parts held up by slings, hoists or jacks must be substantially blocked or cribbed to prevent falling or shifting before employees work under or between them. Bulldozer and scraper blades, end-loader buckets, dump bodies and similar equipment must be fully lowered or blocked when being repaired or when not in use. Controls must be in neutral, motors stopped and brakes set, unless the work requires otherwise.
  • (a)(3)(ii) Parking: whenever equipment is parked, the parking brake must be set, and equipment parked on inclines must also have its wheels chocked.

Batteries and cab glass: 1926.600(a)(4) and (a)(5)

Paragraph (a)(4) says the use, care and charging of all batteries must conform to subpart K of Part 1926, the electrical subpart. Paragraph (a)(5) says cab glass must be safety glass or the equivalent and must not have visible distortion that affects safe operation of the covered machines.

Working near power lines: 1926.600(a)(6)

The power line rules apply when equipment is working or moving near power lines or energized transmitters. They do not apply where lines are de-energized and visibly grounded at the point of work, or where insulating barriers that are not part of or attached to the equipment prevent physical contact with the lines. The clearances in the paragraph are written in terms of a crane or load:

SituationMinimum clearance
Lines rated 50 kV or below, (a)(6)(i)10 feet between the lines and any part of the crane or load
Lines rated over 50 kV, (a)(6)(ii)10 feet plus 0.4 inch for each 1 kV over 50 kV, or twice the length of the line insulator, but never less than 10 feet
In transit, no load, boom lowered, below 50 kV, (a)(6)(iii)4 feet
In transit, over 50 kV up to and including 345 kV10 feet
In transit, up to and including 750 kV16 feet

Other points in (a)(6): where the operator finds it difficult to keep the desired clearance by eye, a designated person must observe the clearance and give timely warning (a)(6)(iv). Cage-type boom guards, insulating links or proximity warning devices may be used on cranes, but they do not change the requirements of any other regulation in Part 1926 (a)(6)(v). Any overhead wire is considered energized unless the owner or electrical utility authorities indicate that it is not and it has been visibly grounded (a)(6)(vi). Before work near transmitter towers where an electrical charge can be induced on equipment or materials, the transmitter must be de-energized or tests must determine whether a charge is induced (a)(6)(vii). Where needed to dissipate induced voltages, equipment must have an electrical ground directly to the upper rotating structure supporting the boom, ground jumper cables must be attached to materials handled by boom equipment, and combustible and flammable materials must be removed from the immediate area. Our cranes and power line safety page covers the separate crane rules in 1926.1408, and our PA One Call page covers the state notice before you dig.

Railroad spurs: 1926.600(a)(7) and the reserved paragraph (b)

Paragraph (a)(7) says derail or bumper blocks must be provided on spur railroad tracks where a rolling car could contact other cars being worked on, enter a building, or reach a work or traffic area. Paragraph (b), specific requirements, is marked reserved, so it contains no rules.

Site clearing: 1926.604

Section 1926.604 is short. Paragraph (a)(1) says employees doing site clearing must be protected from hazards posed by irritant and toxic plants, and must be trained in the first aid treatment available for those hazards. Paragraph (a)(2) says all site clearing equipment must have rollover guards that meet the requirements of Subpart O. Equipment that carries a rider operator must also have an overhead and rear canopy guard. The overhead covering must be at least 1/8-inch steel plate, or 1/4-inch woven wire mesh with openings no larger than 1 inch, or an equivalent material. The opening at the rear of the canopy structure must be covered with at least 1/4-inch woven wire mesh with openings no larger than 1 inch. Paragraph (b), specific requirements, is also marked reserved.

Our hazard communication page and PPE criteria page cover related protection duties.

Practical checklist

  • Light, reflect or barricade equipment left at night, beside a live road or beside active work.
  • Use a tire cage when inflating or mounting split-rim or locking-ring tires.
  • Block or crib anything held up by a sling, hoist or jack before anyone works under it, and lower blades and buckets when parked.
  • Set the parking brake every time, and chock the wheels on a slope.
  • Treat every overhead wire as energized unless the owner or utility says otherwise and it has been visibly grounded.
  • Train site clearing crews in first aid for irritant and toxic plants, and check clearing machines for rollover guards and canopy guards.
Planning information only. This page summarizes public regulation text and is not engineering, legal or safety advice. Check the current CFR text before relying on any number here, and talk to a competent person about your own site.

Sources

SourceUsed for
29 CFR 1926.600, Equipment (OSHA)Paragraphs (a)(1) through (a)(7) and (b)
29 CFR 1926.604, Site clearing (OSHA)Paragraphs (a)(1), (a)(2) and (b)

Checked Nov. 23, 2026. Check the current CFR text at ecfr.gov before relying on details.

Related

Struck-by and backing hazards · Rollover protection · Cranes and power lines · All PA site work regulations

Talk to us about your project

FAQ

What does 1926.600 say about parking equipment?

Paragraph (a)(3)(ii) says the parking brake must be set whenever equipment is parked, and equipment parked on inclines must also have its wheels chocked.

How close can equipment get to power lines under 1926.600?

Paragraph (a)(6) gives 10 feet minimum for lines rated 50 kV or below, with higher figures for higher voltages, and lower in-transit clearances for unloaded equipment with the boom lowered. Check the current text for the exact figures.

Do site clearing crews need training on poisonous plants?

Paragraph 1926.604(a)(1) says employees must be protected from irritant and toxic plants and trained in the first aid treatment available for those hazards.

What guards must site clearing equipment have?

Paragraph 1926.604(a)(2) says rollover guards meeting Subpart O, plus an overhead and rear canopy guard on equipment that carries a rider operator.

General information only, not legal or safety advice. Employers must follow the current OSHA standard and applicable Pennsylvania rules. Source pages checked Nov. 23, 2026.