Backflow Prevention Basics for Sprinkler Systems: Device Types and Testing

Home / Irrigation Basics for Home Landscapes / Backflow prevention basics

Backflow prevention basics for sprinkler systems

Quick answer: A sprinkler system is connected to your drinking-water supply. A backflow preventer is the device that stops water from flowing backward into that supply. The device type, its height above the outlet and its testing are set by your water supplier and local code, so confirm them before you install, move or repair anything.

What backflow is

The EPA Cross-Connection Control Manual defines a cross-connection as the link or channel connecting a source of pollution with a potable water supply. Backsiphonage is reverse flow caused by atmospheric pressure pushing a pollutant toward a potable system that is under vacuum. Backpressure is the case where pressure in an auxiliary system, such as one fed by a pump or boiler, exceeds the potable supply pressure. The manual does not single out lawn irrigation in the portion we reviewed, so the choice of device for a given yard depends on the hazard level and local requirements.

Device types from the EPA manual

DeviceProtects againstNotes from the manual
Atmospheric vacuum breakerBacksiphonage onlyInstall vertically, with no shutoff downstream, at least 6 inches above the final outlet. Cannot be tested once installed.
Pressure vacuum breakerBacksiphonage onlyInstall at least 6 to 12 inches above the existing outlet. Tested in line under pressure.
Double check valve assemblyBacksiphonage and backpressureFor low to medium hazards. Has test cocks and two gate valves so the checks can be tested.
Reduced pressure principle deviceBacksiphonage and backpressureMaximum protection for high hazards. Pressure loss typically runs 10 to 20 psi. Never plug the relief port; discharge from it indicates a malfunction.
Air gapBacksiphonage and backpressureGap must be twice the supply pipe diameter, minimum one inch.

The manual notes that pressure vacuum breakers see broad usage in the agriculture and irrigation market. Hunter Industries, an irrigation manufacturer, says the pressure vacuum breaker is the most commonly installed backflow device on sprinkler systems.

Testing

The manual says the owner’s permission is needed before a test because tests run under no-flow conditions, occupants should be warned not to use water during the test, and local testing requirements may override standard procedures. It also notes that an atmospheric vacuum breaker cannot be tested once installed, while the other devices in the table are built to be tested in line. How often a test is required, and who may perform it, is set locally. We did not find Pennsylvania-specific testing rules in our sources. Ask your water supplier or municipality what they require, and use a certified tester.

Winter and the backflow device

Hunter’s winterizing guide says freezing water in a backflow assembly will damage internal components and can crack the brass body. It says to connect an air compressor after the backflow device and never blow air through it, to blow out the system first and then drain the device, to open test cocks after draining, and to leave ball-valve isolation valves about halfway open at a 45 degree angle. See our winterizing guide.

Homeowner checklist

  • Find the device and note its type (see the table).
  • Check that nothing is stacked against it and that it is not buried or submerged.
  • Keep the test paperwork if your supplier requires it.
  • Do not move or modify it yourself; the install heights in the table are set by the manual and local code, so call a professional.
  • If it leaks or discharges, shut off the supply and call an irrigation or plumbing professional. The EPA manual says discharge from a reduced pressure device’s relief port indicates a malfunction.

Related: in-ground sprinkler system types and common sprinkler problems.

Sources

Get a quote

FAQ

What is backflow?

The EPA manual defines a cross-connection as a link between a source of pollution and a potable water supply. Backsiphonage and backpressure can drive water the wrong way through it, and a preventer is the device that blocks that reverse flow.

Which backflow device is most common on home sprinklers?

Hunter Industries identifies the pressure vacuum breaker as the most commonly installed backflow device.

Does a backflow preventer need testing?

The EPA manual describes how devices are tested and notes that an atmospheric vacuum breaker cannot be tested once installed. How often testing is required is set locally, so ask your water supplier what applies in your area.

Can I blow air through the backflow device when winterizing?

No. Hunter says to connect the compressor after the device and never blow air through it. Blow out the system first, then drain the device.

Planning information only, not a plumbing specification or legal advice. Local code and your water supplier decide which device and testing apply. Sources checked Nov 23, 2026.