Water left in lines and valves can freeze, so the job is to shut off the supply and get the water out. A compressed-air blowout is the common method, and it has hard pressure limits: 50 psi for polyethylene pipe and 80 psi for PVC, per Hunter Industries.
Call (570) 397-9800The steps
- Shut off the irrigation water supply first.
- Drain the water between the shutoff valve and the backflow device using the boiler drain or stop-and-waste cap.
- Manual drain only works if drain valves sit at the ends and low points of the piping.
- Otherwise blow out with compressed air, zone by zone, farthest from the compressor first, until no water leaves the heads.
- Blow out the system first, then drain the backflow device.
- Do not blow air through the backflow device or a pump.
- Leave isolation valves about halfway (45 degrees) open and open the test cocks.
Blowout rules
Polyethylene (black) pipe: 50 psi maximum. PVC (white) pipe: 80 psi maximum. Stay under the rating of the lowest-rated part in the zone.
Wear ANSI-approved eye protection and never stand over components while the system is pressurized.
- Use short cycles, two or three per zone, not one long one.
- Never run the compressor without at least one control valve open.
- Do not keep air moving through dry pipe: friction creates heat.
Compressor size, per the manufacturer: total GPM of the largest zone divided by 7.5 gives the CFM needed. Connect the compressor after the backflow device, never through it. Hunter also says to set dial controllers to OFF and leave power on.
Related guides
Another job before snow.
Timing by bloom type.
Spring, fall and winter checklists.
Questions
What is the maximum air pressure for blowing out sprinkler lines?
Hunter Industries lists 50 psi for polyethylene pipe and 80 psi for PVC pipe, and says to stay below the rating of the lowest-rated component in the zone.
Can I blow air through the backflow preventer?
No. The manufacturer says not to blow the system out through a backflow device or pump. Blow out the system first, then drain the backflow device.
Do I have to use a compressor?
Not if the system has manual drain valves at the end and low points of the piping. If it does not, a compressed-air blowout is the usual alternative. Confirm which applies to your system before you start.
General guidance from one manufacturer, not a Muthler quote or warranty. Your system’s design, pipe type and local freeze timing change the details. Source: Hunter Industries, Winterizing Your Irrigation System, checked Nov 22, 2026. Muthler Landscaping & Construction LLC · 913 Bellefonte Ave, Lock Haven, PA 17745 · (570) 397-9800 · PA HIC #PA212584.