What Is a Post Base?
A post base is the metal connector at the bottom of a post that ties it to the concrete footing or pier. Its job is to hold the post in place and keep the wood off the concrete.
What the deck guide says
The American Wood Council’s deck guide (DCA 6) says pre-manufactured post anchors must be galvanized (p. 9), and that footing thickness has to be coordinated with the post base and its anchor (Table 4, note 3, p. 9). Posts are at least 6×6, no taller than 14 feet, and centered on their footings, with cut ends field-treated with preservative (p. 7). Footings go at least 12 inches below grade or below the frost line, whichever is deeper (p. 9, Table 4, Figure 12). Check your local frost depth with your code office.
The footing under the base
A post base is only as good as the footing it is set in. Table 4 sizes the footing from the beam span and the joist span. One example from the table: a 6-foot beam span with joists under 10 feet calls for a 15-inch round footing 6 inches thick, and a square footing may be 2 inches narrower than the round diameter. Footings must bear on solid ground, and the guide says the building official verifies bearing before concrete is placed. Soils rated under 1,500 pounds per square foot require a soils investigation. Footings closer than 5 feet to an existing house wall must bear at the same elevation as the house footing, and footings may not be built over utility lines or enclosed meters (all p. 9).
Coatings and corrosion
DCA 6 sets one rule for all deck hardware: it must be galvanized or stainless steel (p. 2). Prefabricated hot-dip hardware uses a G-185 coating under ASTM A653, and hardware galvanized after fabrication follows ASTM A123. Fasteners must be hot-dipped galvanized, stainless steel, silicon bronze or copper. Within 300 feet of a salt water shoreline, the guide requires type 304 or 316 stainless fasteners and connectors. That shoreline rule is a reminder that corrosion resistance is a design requirement and not an upgrade.
The post above the base
The post’s size sets its maximum height. The model residential code gives a limit of 14 feet for 6×6 posts and 8 feet for 4×4 and 4×6 posts, measured to the underside of the beam (Table R507.8). At the top, DCA 6 connects the post to the beam with a notch or a column cap, and requires a column cap for a three-ply beam (p. 8). Guard posts are a separate matter. They are at least 4×4 and attach to the deck framing instead of the footing (pp. 15 and 16), while stair footings follow the same 12-inch or frost-line depth rule as deck footings (p. 19).
Common mistakes and limits
- Choosing a post base and footing separately, so the thickness and anchor do not match.
- Using an uncoated anchor, which the guide does not allow.
- Leaving a cut post end untreated. The guide says cut ends must be field-treated with preservative.
- Assuming 12 inches is always deep enough. The rule is 12 inches or the frost line, whichever is deeper, and the frost depth is a local question.
- Using a 4×4 post on a tall deck. The model code limits 4×4 posts to 8 feet.
Planning information only, not engineering or legal advice. These are the guide’s prescriptive limits. Your design or local code may differ.
FAQ
Is a post base the same as a footing?
No. The footing is the concrete in the ground that spreads the load. The post base is the connector on top of it that holds the post.
Does the post base need to be galvanized?
Yes, under the AWC deck guide, pre-manufactured post anchors must be galvanized.
Sources
- American Wood Council, DCA 6 Prescriptive Residential Wood Deck Construction Guide
- International Residential Code, chapter 5, floors (2015 model code text, section R507)
Related
Back to the full glossary. Related terms: Beam, Joist hanger, Frost heave and Guardrail.
Planning a deck or addition? Contact Muthler Landscaping & Construction.