What Is ADA Ramp Slope? The 1:12 Limit, 30-Inch Rise, Landings and Handrails
ADA ramp slope is the running slope allowed on a ramp that forms part of an accessible route. The U.S. Access Board’s guide to the ADA Accessibility Standards says the maximum running slope is 1:12, which is 8.33 percent, with a maximum cross slope of 1:48 and a maximum rise of 30 inches per run. This is a federal source, and the guide notes that it does not cover curb ramps in public rights-of-way.
ADA ramp slope and the terms around it
- Running slope: the slope along the direction of travel. The Access Board guide gives 1:12 maximum, 8.33 percent, and says changes in level other than running and cross slope are not permitted along runs.
- Cross slope: the slope across the ramp, 1:48 maximum in the guide. See cross slope.
- Rise: 30 inches maximum per run. The guide says there is no limit on the number of runs, though long ramps are strenuous.
- Landing: a level area required at the top and bottom of each run. The guide says landings must prevent water accumulation and that no change in level greater than 1:48 is permitted at them.
- Curb ramp: a ramp cut through or built up to a curb, with its own section in the guide. See curb cut.
- Handrail: required on both sides of ramps with a rise greater than 6 inches.
- Edge protection: the guide lists curbs, rails, pickets or extended surfaces as ways to provide it. See guardrail for a related term.
Why it matters on a job
The Access Board guide says ramps or curb ramps are required on accessible routes to span changes in level greater than one-half inch, and that portions of accessible routes with running slopes steeper than 5 percent must be treated as ramps. Elevators and, under certain conditions, platform lifts may be used instead. The guide also says required ramps must be permanent and installed during construction or alteration, with few exceptions.
Core ramp requirements
The guide lists these requirements for ramps in Section 405 of the Standards:
- Running slope: 1:12 maximum, which is 8.33 percent.
- Cross slope: 1:48 maximum.
- Rise: 30 inches maximum per run, with no limit on the number of runs.
- Clear width: 36 inches minimum, measured between handrails where provided.
- Surfaces: firm, stable and slip-resistant on runs and landings. The guide names no specific materials.
- Landings: level at the top and bottom of each run, at least 60 inches long and at least as wide as the run, according to the guide’s image notes.
- Intermediate landings where a ramp changes direction: at least 60 inches by 60 inches clear, with handrails, edge protection and posts not intruding.
For exterior ramps the guide recommends a 7.5 percent maximum running slope and a 1.5 percent maximum cross slope to accommodate construction variances. That is a recommendation in the guide, not a requirement.
Alterations with limited space
For alterations only, where space is limited, the guide allows a 1:10 maximum slope with a 6-inch maximum rise, or a 1:8 maximum slope with a 3-inch maximum rise.
Landings and drainage
The guide says landings must drain and that landing slopes up to 1:48 are permitted for drainage. It says door maneuvering clearances may overlap ramp landings and recommends placing door swings outside the landings. It says detail on ramp lighting, drainage design beyond the 1:48 landing slope, and maintenance is not addressed.
Handrails and edge protection
Handrails are required on both sides of ramps with a rise greater than 6 inches. In the guide’s image notes the height is 34 to 38 inches, consistent along the run. Extensions go at least 12 inches beyond the top and bottom of each run in the direction of travel. A circular handrail section is 1.25 to 2 inches in diameter. A non-circular section is limited to 2.25 inches maximum dimension and a perimeter of 4 to 6.25 inches.
Edge protection can be curbs at least 4 inches high, rails or barriers that stop a 4-inch sphere, vertical pickets spaced the same way, or run and landing surfaces extending at least 12 inches beyond the inside face of the handrails. The guide says edge protection is not required at ramps 6 inches high or less with side flares, at landings serving an adjoining run or stairway, or at landing sides with vertical drop-offs of one-half inch or less within 10 inches of the minimum landing area.
Curb ramps
For curb ramps, the guide gives the same 1:12 maximum running slope and 1:48 maximum cross slope. It requires a top landing at least 36 inches long, and optional side flares that cannot exceed 1:10, or 1:12 in alterations without a top landing. It says transitions to the street must be smooth with no lip at the grade break, and that the counter slope may be up to 1:20, according to its image notes. It also requires curb ramps to stay out of vehicular traffic lanes, parking spaces and access aisles.
The guide says detectable warnings are required at curb ramps at transit facilities covered by DOT’s Standards, not at non-transit facilities covered by DOJ’s Standards. It says its guide does not cover curb ramps along public streets and sidewalks, which are addressed by separate public rights-of-way guidelines under development.
Common mistakes
- Building steeper than 1:12 on new work. The guide’s steeper options apply to alterations with limited space only.
- Skipping landings at direction changes. The guide requires intermediate landings at least 60 inches by 60 inches.
- Letting water pond on landings. The guide says landings must prevent water accumulation.
- Leaving handrails off a ramp over 6 inches of rise. The guide requires them on both sides.
- Using a temporary ramp as the required one. The guide says required ramps must be permanent, with few exceptions.
- Treating the 7.5 percent recommendation as the legal limit, or the other way around. The guide separates the 1:12 requirement from its recommendation for construction variances.
What the guide does not say
The guide gives only ‘firm, stable and slip-resistant’ for surfaces and names no materials, and it does not address ramp lighting or maintenance. It does not cover public rights-of-way curb ramps, and it leaves local traffic-calming and raised-crossing requirements to local standards. It defers egress ramp widths to life safety codes. It does not cover Pennsylvania building code or Pennsylvania accessibility rules. Where a source is silent, this page says so.
ADA ramp slope FAQ
What is the maximum ADA ramp slope?
The U.S. Access Board guide gives 1:12 maximum, which is 8.33 percent, for the running slope of a ramp.
How much rise can one ADA ramp run have?
The guide says 30 inches maximum per run. It says there is no limit on the number of runs.
What is the maximum ADA cross slope on a ramp?
The guide gives 1:48 maximum for ramp cross slope, and the same 1:48 limit applies to landings.
When are handrails required on an ADA ramp?
The guide says handrails are required on both sides of ramps with a rise greater than 6 inches.
Sources
- U.S. Access Board, Guide to the ADA Accessibility Standards, Chapter 4: Ramps and Curb Ramps. Federal source, not specific to Pennsylvania. Several figures are marked in the guide as coming from image descriptions.
Verify thresholds and dimensions against the current source before you rely on them.
Keep reading
- Hardscape and Site Work Glossary
- Related terms: curb cut, cross slope, guardrail, subgrade, paver, edge restraint