Guides · Deck code rules · Stairs
Deck stair rules: width, stringers, landings and handrails
Deck stairs fall under the stair section of the model IRC, and the AWC DCA 6 guide turns that into a build recipe for wood stringers. This page covers the numbers we could source and says plainly which ones we did not.
The AWC DCA 6 guide calls for stairs at least 36 inches wide, stringers at least 2×12, three cut stringers when stringers are cut, and a landing when the total rise is more than 12′-0″ (p. 20, IRC R311.7). A handrail is required at four or more risers, set 34 to 38 inches high (p. 22, R311.7.8). Riser height and tread depth limits are in R311.7 and are not quoted here, so read them in the code or ask your code office.
Stair rules by section
| Point | What the source states | Section |
|---|---|---|
| Width | Stairs at least 36 inches wide. | AWC DCA 6, p. 20 (IRC R311.7) |
| Stringer size | Stringers at least 2×12. | AWC DCA 6, p. 20 |
| Cut stringers | Three stringers if only cut stringers are used. | AWC DCA 6, p. 20 |
| Landing | A landing is needed if the total height is more than 12′-0″. | AWC DCA 6, p. 20 (IRC R311.7) |
| Handrail | Required with four or more risers; 34 to 38 inches high. | AWC DCA 6, p. 22 (IRC R311.7.8) |
| Lighting | Stairs and landings are illuminated from the top landing. | AWC DCA 6, p. 22 (IRC R303.7) |
| Riser and tread | Shown in the guide’s stair figures; limits are set in R311.7. | AWC DCA 6, Figs. 27 and 28 |
See the glossary entry for stair stringer, and our pages on deck guards and deck lighting rules. Stairs usually land on a footing or a pad, so read deck footing requirements too.
Questions
How wide do deck stairs have to be?
The AWC DCA 6 guide calls for at least 36 inches (p. 20, IRC R311.7).
What size stringers does the AWC guide use?
At least 2×12, and three stringers if only cut stringers are used (DCA 6, p. 20).
When do deck stairs need a handrail?
With four or more risers, set 34 to 38 inches high (DCA 6, p. 22, IRC R311.7.8).
What are the riser height and tread depth limits?
They are set in IRC R311.7 and shown in DCA 6 Figures 27 and 28. We have not quoted the numbers here, so check the code edition your office enforces.
Sources: American Wood Council, DCA 6 (2015); PA L&I, UCC regulations and statutes. Checked Nov. 22, 2026.
Muthler Landscaping & Construction · Lock Haven, PA
Planning a deck?
We build decks across central Pennsylvania. Tell us what you have in mind.
Get a quoteAll guidesMuthler Landscaping & Construction LLC · 913 Bellefonte Ave, Lock Haven, PA 17745 · (570) 397-9800 · PA HIC #PA212584.