Guides · Deck code rules · Lighting
Deck lighting rules: stair and landing lighting under the IRC
Deck lighting that the code requires is about safe stairs, not mood. Here is what the AWC deck guide and the model IRC say, and what they leave to your local rules.
Under IRC R303.7 as cited in the AWC DCA 6 guide (2015 IRC), deck stairs and landings must be illuminated from a light at the top landing, with the switch operated from inside the house. Motion-sensor or timed lighting is acceptable (p. 22). We did not find other lighting requirements for decks in the sources checked, so ask your code office about guard or deck lighting.
What the sources state
| Point | What the source states | Section |
|---|---|---|
| Stair and landing light | Stairways have a light source at the top landing so that all stairs and landings are illuminated. | AWC DCA 6, p. 22 (IRC R303.7, 2015 edition) |
| Switch | The light switch is operated from inside the house. | AWC DCA 6, p. 22 |
| Controls | Motion-detected or timed switches are acceptable. | AWC DCA 6, p. 22 |
| Approval | All construction and materials must be approved by the authority having jurisdiction. | AWC DCA 6, p. 1 |
| Use | Decks are not used or occupied until final inspection and approval is obtained. | AWC DCA 6, p. 3 |
What this does and does not cover
Lighting at the stair and landing, so the way down from the deck can be seen. The guide does not address exterior stair lighting separately; this is the only lighting provision it lists.
Decorative or railing lights, outlets and wiring. Electrical work has its own rules, so ask your code office what permit or licensed trade it requires.
See deck stair rules and guard height rules.
Other stair points in the same guide
The AWC guide (2015 IRC) puts the lighting rule next to the stair rules, and a deck stair that fails any of them will not pass inspection. It lists stairs at least 36 in. wide and rectangular landings at least 36 in. in the direction of travel and at least as wide as the stairway (p. 20). Stringers are at least 2×12, with at least three for cut-stringer stairs (p. 20). A handrail is required on at least one side of stairs with four or more risers, at 34 to 38 in. high (p. 22). Stair posts bear on footings at least 12 in. below undisturbed ground or below the frost line, whichever is deeper (p. 22). Decks more than 30 in. above grade need a guard (p. 19). Plan the light fixture and its wiring path while the stair and landing are still open to work on, which is our suggestion rather than a code requirement.
Pennsylvania and the code edition
See also do you need a permit for a deck in Pennsylvania.
Inspection and when to ask for help
The AWC guide says the building official verifies footing bearing in the field before concrete is placed (p. 12), and says to contact local utilities (call 811) before digging footings (p. 12). Do not use the deck until final inspection and approval. If you are unsure whether your light, switch location or controls satisfy the local code, the code office is the authority. A plan reviewer can tell you before you buy fixtures.
Questions
Do deck stairs need a light?
The AWC guide says stairs and landings are illuminated from the top landing (p. 22, IRC R303.7).
Can I use a motion sensor light?
Yes. The AWC guide says motion-sensor or timed lighting is acceptable (p. 22).
Where does the switch go?
The AWC guide says the switch is operated from inside the house (p. 22).
Can I use the deck before the inspection?
No. The AWC guide says decks are not used or occupied until final inspection and approval is obtained (p. 3).
Sources: American Wood Council, DCA 6 (2015); PA L&I, UCC regulations and statutes. Checked Nov. 23, 2026.