Deck ledger attachment rules: IRC R507.9 and the AWC guide

The ledger is where an attached deck hangs off the house, and it is the connection the code is strictest about. Here is what the model IRC and the AWC DCA 6 deck guide say about the ledger board, the house band joist and the fasteners.

Quick answer

The model IRC calls for a ledger of at least 2×8 pressure-treated southern yellow pine, incised hem-fir or naturally durable No. 2 lumber (R507.9.1.1), fastened to a band joist per Tables R507.9.1.3(1) and (2) with hot-dip galvanized or stainless fasteners. Do not attach to stone or masonry veneer, and do not hang a beam off the ledger. Confirm the edition with your code office.

Ledger rules by section

PointWhat the source statesSection
Ledger lumberAt least 2×8, pressure-treated southern yellow pine, incised hem-fir or naturally durable No. 2.IRC R507.9.1.1
LoadsNo concentrated loads from a beam or girder on the ledger.IRC R507.9.1.1
Where it can attachNot onto stone or masonry veneer.IRC R507.9.1.1
House band joistAt least 2 inch nominal SPF lumber or a 1 by 9-1/2 inch LVL.IRC R507.9.1.2
FastenersSized and spaced per Tables R507.9.1.3(1) and (2); hot-dip galvanized or stainless steel.IRC R507.9.1.3
FlashingRequired; siding is removed so flashing can be installed behind it.AWC DCA 6, p. 13
Lag screw holes1/2 inch holes in the ledger and 5/16 inch holes in the band joist.AWC DCA 6, p. 16

Lag screw spacing (AWC DCA 6, Table 5, p. 15)

Joist spanLag spacing, inches on center
6′-0″ or less30
6′-1″ to 8′-0″23
8′-1″ to 10′-0″18
10′-1″ to 12′-0″15
12′-1″ to 14′-0″13
14′-1″ to 16′-0″11
16′-1″ to 18′-0″10

The AWC table is tied to the guide’s assumptions, so check it against the exact conditions in DCA 6 before you use it. Related: rim joist, joist, joist hanger and how to flash a deck ledger.

Planning information, not engineering or legal advice. Section numbers follow the 2018 IRC numbering in Penn State’s deck materials and the 2015 AWC DCA 6. Pennsylvania began enforcing the 2021 International Residential Code on Jan. 1, 2026, so section numbers and some values may differ; confirm with your local code office. Pennsylvania L&I says the 2015 International Codes were adopted as of October 1, 2018, and numbering differs between editions. The PA-adopted edition and local amendments may differ, so confirm with your municipal code office before you build.

Questions

What size ledger board does a deck need?

At least 2×8 pressure-treated southern yellow pine, incised hem-fir or naturally durable No. 2 lumber (IRC R507.9.1.1).

Can a deck ledger attach to brick veneer?

No. The model IRC does not allow attachment to stone or masonry veneer (R507.9.1.1).

Can the deck beam bear on the ledger?

No. R507.9.1.1 does not allow concentrated loads from a beam or girder on the ledger.

What fasteners go in a ledger?

Fasteners follow Tables R507.9.1.3(1) and (2) and must be hot-dip galvanized or stainless steel (R507.9.1.3). The AWC guide gives 1/2 inch lag screw holes in the ledger and 5/16 inch holes in the band joist (p. 16).

Sources: American Wood Council, DCA 6 (2015); Penn State Housing Research Center, deck design handout; 2018 IRC deck construction summary; PA L&I, UCC regulations and statutes. Checked Nov. 22, 2026.

Muthler Landscaping & Construction · Lock Haven, PA