Guides · Deck code rules · Ledger
Deck ledger attachment rules: IRC R507.9 and the AWC guide
The ledger is where an attached deck hangs off the house, and it is the connection the code is strictest about. Here is what the model IRC and the AWC DCA 6 deck guide say about the ledger board, the house band joist and the fasteners.
The model IRC calls for a ledger of at least 2×8 pressure-treated southern yellow pine, incised hem-fir or naturally durable No. 2 lumber (R507.9.1.1), fastened to a band joist per Tables R507.9.1.3(1) and (2) with hot-dip galvanized or stainless fasteners. Do not attach to stone or masonry veneer, and do not hang a beam off the ledger. Confirm the edition with your code office.
Ledger rules by section
| Point | What the source states | Section |
|---|---|---|
| Ledger lumber | At least 2×8, pressure-treated southern yellow pine, incised hem-fir or naturally durable No. 2. | IRC R507.9.1.1 |
| Loads | No concentrated loads from a beam or girder on the ledger. | IRC R507.9.1.1 |
| Where it can attach | Not onto stone or masonry veneer. | IRC R507.9.1.1 |
| House band joist | At least 2 inch nominal SPF lumber or a 1 by 9-1/2 inch LVL. | IRC R507.9.1.2 |
| Fasteners | Sized and spaced per Tables R507.9.1.3(1) and (2); hot-dip galvanized or stainless steel. | IRC R507.9.1.3 |
| Flashing | Required; siding is removed so flashing can be installed behind it. | AWC DCA 6, p. 13 |
| Lag screw holes | 1/2 inch holes in the ledger and 5/16 inch holes in the band joist. | AWC DCA 6, p. 16 |
Lag screw spacing (AWC DCA 6, Table 5, p. 15)
| Joist span | Lag spacing, inches on center |
|---|---|
| 6′-0″ or less | 30 |
| 6′-1″ to 8′-0″ | 23 |
| 8′-1″ to 10′-0″ | 18 |
| 10′-1″ to 12′-0″ | 15 |
| 12′-1″ to 14′-0″ | 13 |
| 14′-1″ to 16′-0″ | 11 |
| 16′-1″ to 18′-0″ | 10 |
The AWC table is tied to the guide’s assumptions, so check it against the exact conditions in DCA 6 before you use it. Related: rim joist, joist, joist hanger and how to flash a deck ledger.
Questions
What size ledger board does a deck need?
At least 2×8 pressure-treated southern yellow pine, incised hem-fir or naturally durable No. 2 lumber (IRC R507.9.1.1).
Can a deck ledger attach to brick veneer?
No. The model IRC does not allow attachment to stone or masonry veneer (R507.9.1.1).
Can the deck beam bear on the ledger?
No. R507.9.1.1 does not allow concentrated loads from a beam or girder on the ledger.
What fasteners go in a ledger?
Fasteners follow Tables R507.9.1.3(1) and (2) and must be hot-dip galvanized or stainless steel (R507.9.1.3). The AWC guide gives 1/2 inch lag screw holes in the ledger and 5/16 inch holes in the band joist (p. 16).
Sources: American Wood Council, DCA 6 (2015); Penn State Housing Research Center, deck design handout; 2018 IRC deck construction summary; PA L&I, UCC regulations and statutes. Checked Nov. 22, 2026.