Skip to content Groundwork Design Co.Want a design?Custom patio, wall, deck and yard plans, drawn by builders. Anywhere in the U.S. From $349.Start here
LOCK HAVEN, PA · PA HIC #PA212584 · INSURED FREE ESTIMATES · CALL OR TEXT
PAGE
Home / Aggregates / Asphalt wearing course

PennDOT asphalt wearing course basics

Quick answer: Under the 2020 edition of Pub 408, wearing and binder courses are in Section 413, with Superpave mixes named by nominal maximum aggregate size (9.5, 12.5, 19.0 mm and so on). Two PennDOT documents disagree on minimum VMA, so check which governs.

One section now covers wearing and binder courses

If you are reading an older Pennsylvania spec, you may see Section 409 (hot mix wearing and binder courses) or Section 411 (warm mix). Penn State’s 2025 asphalt plant refresher manual lists both as merged into Section 413 in April 2020, in a Pub 408/2020 Change 9 listing. Section 413 is titled “Superpave Asphalt Mixture Design and Construction of Plant Mixed Courses with PWL and LTS Testing.” So under the 2020 edition and later, Section 413 is where the wearing course rules live. A thin overlay Section 412 (6.3 mm mix) also appears in the same manual.

Mix size is named by nominal maximum aggregate size

PennDOT names Superpave mixes by NMAS in millimeters: 4.75, 9.5, 12.5, 19.0, 25.0 and 37.5. Section 413 Table B, as shown in the Penn State manual, sets a minimum voids in mineral aggregate (VMA) for each size.

NMASMinimum VMA, Pub 408 Section 413 Table BMinimum VMA, SOL 481-24-01 Table 7
4.75 mm16.0%Not shown
9.5 mm15.5%16.0%
12.5 mm14.5%15.0%
19.0 mm13.5%14.0%
25.0 mm12.5%13.0%
37.5 mm11.5%12.0%

The two documents disagree

The right-hand column comes from a PennDOT Solicitation (SOL 481-24-01, issued February 23, 2024) that cites Bulletin 27, 2003 edition. Every value is exactly half a point higher than the Section 413 Table B value, apart from 4.75 mm, which the SOL table does not show. The manual flags the mismatch itself and says to check which document governs your project before using either set. This page does not pick a winner.

Binder and design traffic

  • Binder grades: Section 413 Table A lists PG 58S-28, PG 64S-22 and PG 64E-22, with other binders per Bulletin 25. Section 412 thin overlays use PG 64E-22, and a special provision dated October 6, 2023 allows PG 64S-22.
  • Gyrations: Under SOL 481-24-01, binder and wearing courses use Ndesign 50 when design ESALs are under 0.3 million and Ndesign 75 at 0.3 million or more. Base courses use Ndesign 75 at all traffic levels.

Compacted lift thickness

Table G in the manual gives these compacted lift thicknesses: 1.5 inches for a 9.5 mm wearing course, 2.5 inches for a 19 mm wearing or binder course, and 3 inches for a 25 mm binder course. This page does not give a 12.5 mm value. The same section says the minimum thickness for acceptance by cores under standard construction is 2 inches.

Density and lot rules

For partially completed lots, Table E lists a density of at least 91.0% and no more than 98.0% for standard 9.5, 12.5, 19 and 25 mm wearing or binder courses, and at least 92.0% for the same mixes under RPS. Base courses (25 and 37.5 mm) run at least 90.0% and under 100.0%. A normal lot is 2,500 tons, split into five sublots of 500 tons.

Crushed stone in the mix

Section 703 as copied in Penn State’s Aggregate Course Book (Pub 408/2020 Change No. 2) says gravel used in asphalt wearing courses needs at least 85% crushed particles with two fractured faces unless otherwise specified. For comparison, an open-graded subbase calls for at least 75% with three faces.

What a homeowner can use from this

These numbers come from plant and road specifications. None of the sources discuss driveways or patios, so this page does not say what mix a residential paving job should use. What you can do is ask your paving contractor for the mix designation (for example, “9.5 mm wearing course”), the binder grade, the planned compacted thickness, and how density will be checked. Compare the answers against the project specification, not against this page.

Editions

The Section 413 values above are labeled Pub 408/2020. PennDOT’s edition index also lists a 2026 edition effective April 10, 2026 to April 12, 2030. Values in the 2026 edition may differ.

Common mistakes

  • Quoting Section 409 or 411 on a current job when both were merged into Section 413 in April 2020.
  • Mixing VMA values from different documents.
  • Assuming a 12.5 mm lift thickness without checking Table G in your edition.
  • Using this page instead of the plan notes.

Sources

Related

All aggregates · PennDOT OGS · PennDOT 2A subbase · Crushed stone vs river gravel

Get a quote

FAQ

Which Pub 408 section covers asphalt wearing courses?

Section 413. Sections 409 and 411 were merged into it in April 2020, according to Penn State’s 2025 plant refresher manual.

What do 9.5 mm and 19 mm mean in an asphalt mix?

They are nominal maximum aggregate size in millimeters, used to name PennDOT Superpave mixes: 4.75, 9.5, 12.5, 19.0, 25.0 and 37.5 mm.

How thick is a 9.5 mm wearing course?

Table G in the Penn State manual shows 1.5 inches compacted. No 12.5 mm value is given here.

Why do two PennDOT documents show different VMA numbers?

Section 413 Table B and SOL 481-24-01 Table 7 differ by half a point for the sizes both list. Check which governs your project.

Planning information only. The project specification and the contract edition of Pub 408 govern. Sources checked Nov 23, 2026.