Central PA soils · Drainage and water
Percolation test in Pennsylvania: what the rule requires
A percolation test is how Pennsylvania’s sewage rules measure how fast water drops in a hole dug in the proposed absorption area. This is a plain-English summary of the procedure in 25 Pa. Code § 73.15, not a substitute for it.
At least six holes, spread evenly over the proposed absorption area, each 6 to 10 inches across. Presoak 8 to 24 hours, then take readings until you have 8 or the drop stabilizes. Results are in minutes per inch. Holes too slow to measure count as 240 minutes per inch. Checked Nov. 22, 2026.
The procedure in summary
| Step | What § 73.15 says |
|---|---|
| Number of holes | At least six, in separate holes spread evenly over the proposed absorption area. Only holes inside that area count toward the average. |
| Hole size | Uniform diameter of 6 to 10 inches. |
| Hole depth | Limiting zone 60 inches or deeper: dig to the depth of the proposed absorption area. Limiting zone above 60 inches (water table, rock, other layer or slowly permeable soil): 20 inches. Fractured, open-jointed or loose rock above 60 inches: 8 inches above that zone or 20 inches, whichever is less. |
| Preparing the hole | Scarify the bottom and sides to remove smeared soil, remove loose material, and place 2 inches of coarse sand or fine gravel in the bottom. |
| Presoak | Fill to at least 12 inches over the gravel and let it stand 8 to 24 hours. Right before testing, keep at least 6 inches over the gravel, readjusting every 30 minutes for 1 hour. |
| Reading interval | If water remains in the hole after the final presoak, 30 minutes between readings. If none remains, 10 minutes (an optional reduction). |
| Measuring | Measure from a fixed reference point and keep water about 6 inches over the gravel. Continue until 8 readings or until the drop stabilizes, meaning four consecutive readings with a 1/4 inch or smaller spread. |
| Result | The drop in the final period, in minutes per inch, averaged across holes. |
Special cases
Assign 240 minutes per inch. The absorption area may go over these holes only if the average falls within the limits in § 73.16, Table A.
Holes dry at the end of a 10-minute interval are excluded from the average.
Don’t design or install over those holes unless the local agency finds an anomaly and a retest is within limits. Otherwise it may accept the remaining holes plus added tests outside the dry area.
The acceptable rate range
§ 73.16, Table A lists percolation rates in minutes per inch by band: under 3 is unsuitable, then bands of 3 to 5, 6 to 15, 16 to 30, 31 to 45, 46 to 60, 61 to 90, 91 to 120, 121 to 150 and 151 to 180, and rates above 181 are unsuitable. The table gives different required areas for standard systems and for sand mounds and subsurface sand filters. A footnote says some bands may be considered for experimental or alternate proposals. See also perched water tables as one kind of limiting zone.
Questions
How many percolation test holes does Pennsylvania require?
At least six, in separate holes spread evenly over the proposed absorption area, under 25 Pa. Code § 73.15.
How big is a perc test hole in PA?
A uniform diameter of 6 to 10 inches. Depth is 20 inches where a limiting zone sits above 60 inches; otherwise it matches the proposed absorption area depth.
How long do you presoak?
The initial presoak stands 8 to 24 hours with at least 12 inches of water over the gravel, followed by a final presoak of at least 6 inches for 1 hour, readjusted every 30 minutes.
What happens if a hole is too slow to measure?
It is assigned 240 minutes per inch, and the absorption area may go over it only if the average rate falls within the limits in § 73.16, Table A.
Sources: 25 Pa. Code § 73.15 Percolation tests (Pennsylvania DEP sewage rules, text via Cornell LII); 25 Pa. Code § 73.16 (Table A); Penn State Extension, Infiltrating Stormwater (updated Sept. 17, 2025). Checked Nov. 22, 2026.
Muthler Landscaping & Construction · Lock Haven, PA
Wet yard or a build coming up?
Our crews work central Pennsylvania from Lock Haven. If your job is in our area, we handle the grading, drainage and excavation that go with a patio, wall or driveway.