Quick answer: OSHA requires a stairway or ladder wherever a personnel access point has an elevation break of 19 inches or more, unless a ramp, runway, sloped embankment or hoist is provided. Temporary stairs need landings at least every 12 feet of vertical rise and must be installed between 30 and 50 degrees from horizontal (29 CFR 1926.1051 and 1926.1052).
Where the rules live
Stairways and ladders on construction sites are covered by Subpart X of 29 CFR Part 1926. Section 1926.1051 sets general requirements for access between levels, 1926.1052 covers stairways, and 1926.1060 covers training. Subpart X sits alongside the fall protection rules in Subpart M. This page summarizes the eCFR text for homeowners, general contractors and crew leads who want to understand what a compliant temporary stair looks like on a deck, retaining wall, basement or addition job. The eCFR notes that its web version is authoritative but unofficial, so check the published CFR before relying on any single detail.
When a stairway or ladder is required
Under 1926.1051(a), a stairway or ladder must be provided at all personnel access points where there is an elevation break of 19 inches (48 cm) or more. The exception is where a ramp, runway, sloped embankment or personnel hoist is provided instead. That 19-inch figure matters on grading and foundation work, where a trench edge, a footing or a first-floor deck can easily create a break that people climb over.
- Employees may not use spiral stairways that will not be a permanent part of the structure.
- A double-cleated ladder or at least two separate ladders must be provided when ladders are the only way in or out of a working area that serves 25 or more employees, or when a ladder must serve two-way traffic.
- If a building has only one point of access between levels, that point must be kept clear for free passage. If work or equipment blocks it, a second point of access must be provided and used.
- If a building has two or more points of access between levels, at least one must be kept clear.
Section 1926.1051(b) adds a timing rule. The employer must provide and install all stairway and ladder fall protection systems the subpart requires, and meet its other requirements, before employees begin work that needs those systems.
Geometry of a temporary stair
| Item | What 1926.1052(a) says |
|---|---|
| Landings | At least 30 inches deep in the direction of travel and at least 22 inches wide, at every 12 feet or less of vertical rise |
| Angle | Stairs must be installed between 30 and 50 degrees from horizontal |
| Risers and treads | Uniform within each flight; variation may not exceed 1/4 inch in any stairway system |
| Doors and gates | A platform is required where a door or gate opens directly onto a stairway, and the door swing cannot reduce the platform’s effective width to less than 20 inches |
The rule gives no numeric limit for riser height or tread depth. It requires only that they be uniform, and that includes any foundation structure used as treads. Uneven steps are a familiar trip hazard, which is why the 1/4-inch variation limit applies across the whole stairway system.
The rule also says metal pan landings and treads must be secured in place before they are filled with concrete or other material. Stairways must be free of hazardous projections such as protruding nails, and slippery conditions must be eliminated before a stairway is used to reach other levels. On a winter job that means clearing ice, mud or wet leaves before anyone climbs.
Temporary service and pan stairs
Section 1926.1052(b) addresses stairs used before they are finished. Except during stairway construction, foot traffic is prohibited on pan stairs where the treads or landings are to be filled in later, unless the stairs have temporary solid treads fitted at least to the top edge of each pan. Worn temporary treads must be replaced. Foot traffic is likewise prohibited on skeleton metal stairs that are waiting for permanent treads or landings, unless secured temporary treads and landings cover the full area. Temporary treads must be solid, such as wood, and installed the full width and depth of the stair.
Stairrails and handrails
Stairways with four or more risers, or rising more than 30 inches, whichever is less, need at least one handrail and a stairrail system along each unprotected side or edge, according to 1926.1052(c). Winding and spiral stairways need a handrail offset to prevent walking where the tread width is less than 6 inches.
- Stairrail height: at least 36 inches for rails installed after March 15, 1991; between 30 and 34 inches for rails installed before that date.
- Handrail height: between 30 and 37 inches. When the top edge of a stairrail also serves as the handrail, its height must be between 36 and 37 inches.
- Fill-in members: midrails, screens, mesh or intermediate members must fill the space between the top rail and the steps. Midrails sit midway between the top edge and the steps, balusters can be no more than 19 inches apart, and any openings can be no more than 19 inches wide.
- Strength: handrails and the top rails of stairrails must withstand at least 200 pounds applied within 2 inches of the top edge, in any downward or outward direction, without failure.
- Surface: rails must be surfaced to prevent punctures, lacerations and clothing snags, and must give an adequate handhold. Rail ends must not create a projection hazard.
- Clearance: temporary handrails need at least 3 inches of clearance from walls, stairrails and other objects.
Unprotected sides and edges of stairway landings must have guardrail systems that meet Subpart M.
Training under 1926.1060
The employer must provide a training program for each employee who uses ladders and stairways, as necessary. The program must help employees recognize ladder and stairway hazards and train them in the procedures that minimize those hazards. A competent person must train each employee, as applicable, on the nature of fall hazards in the work area, the correct procedures for erecting, maintaining and disassembling the fall protection systems in use, the proper construction, use, placement and care in handling of all stairways and ladders, the maximum intended load-carrying capacities of the ladders used, and the standards in the subpart. Retraining must be provided as necessary to maintain that understanding and knowledge.
Common mistakes
- Climbing over a 19-inch or greater elevation break with no stair, ladder, ramp or hoist.
- Building a long run of stairs without a landing at each 12 feet of rise.
- Unequal risers or treads that exceed the 1/4-inch limit.
- Leaving an open side of a stair with four or more risers without a stairrail.
- Letting ice, mud or debris build up on treads.
- Walking on pan stairs before temporary solid treads are in place.
When to get professional help
This page covers only part of Subpart X and does not replace the regulation. Stair design for permanent structures belongs under the building code and a licensed designer, and a competent person must inspect and approve temporary stairs and fall protection. A written safety program or a training plan should come from a qualified safety professional or OSHA’s consultation resources.
Sources
Sources checked Nov 23, 2026.
Related
Fall protection and ladder basics · Scaffold and aerial lift basics · Competent person for excavations · All PA site work regulations
FAQ
When does OSHA require a stairway or ladder on a construction site?
Under 1926.1051(a), one must be provided at personnel access points with an elevation break of 19 inches or more, unless a ramp, runway, sloped embankment or personnel hoist is provided.
How often do temporary stairs need a landing?
Section 1926.1052(a) calls for landings at least 30 inches deep and 22 inches wide at every 12 feet or less of vertical rise.
What angle must temporary stairs be installed at?
Stairs must be installed between 30 and 50 degrees from horizontal under 1926.1052(a).
When is a handrail required on a stairway?
Stairways with four or more risers, or rising more than 30 inches, whichever is less, need at least one handrail and a stairrail system along each unprotected side or edge.