Home / PA site regulations / First aid and medical services

First aid and medical services on job sites

Quick answer: Under 29 CFR 1926.50(b), provisions must be made before the project starts for prompt medical attention in case of serious injury, and 1926.50(c) requires a worker with valid first-aid training on site when no infirmary, clinic, hospital or physician is reasonably accessible.

What 1926.50 covers

Section 1926.50 is titled Medical Services and First Aid. It applies to construction work and sets out seven things employers have to think about before a crew starts digging: medical advice, prompt treatment of serious injury, first-aid trained personnel, first aid kits, transport of injured people, emergency communication and eyewash or drenching facilities. The paragraphs below follow the order of the regulation.

Medical advice and prompt attention: (a) and (b)

Paragraph (a) requires the employer to ensure that medical personnel are available for advice and consultation on matters of occupational health. Paragraph (b) says provisions shall be made prior to commencement of the project for prompt medical attention in case of serious injury. The word that matters is before. Deciding where the nearest hospital is after somebody is hurt is too late. For a remote property, a steep slope, or a back lot in a rural part of the county, that planning step includes working out how an ambulance would actually reach the injured person.

First-aid trained worker: (c)

Paragraph (c) says that if no infirmary, clinic, hospital or physician is reasonably accessible to treat injured employees, a worker with valid first-aid training must be present at the worksite. The regulation does not turn on the size of the job. It turns on access to care. A small crew working far from a clinic is exactly the situation the paragraph is aimed at, so employers should decide who holds current first-aid training and make sure that person is on site each day.

First aid kits: (d)

Under paragraph (d)(1), first aid supplies must be easily accessible when required. Paragraph (d)(2) requires the kit to be in a weatherproof container with individually sealed packages for each type of item. The employer must check it before each job and at least weekly on each job to make sure expended items are replaced. A kit left in a truck bed through a wet spring can fail the weatherproof requirement, and an unchecked kit with empty packages does not meet the check requirement.

Transport and emergency communication: (e) and (f)

Paragraph (e) requires the employer to provide proper equipment for prompt transport of injured persons to a physician or hospital, or a communication system for contacting ambulance service. Paragraph (f) addresses telephone numbers. Where 911 is not available, the numbers of physicians, hospitals and ambulances must be conspicuously posted. Where 911 is available and a communication system is used, the employer must ensure the system works and, in areas where the caller’s location is not automatically provided, post the worksite’s latitude and longitude or other effective location information. This does not apply to land lines with automatic 911 location identification.

For crews that rely on cell phones in rural central Pennsylvania, the practical point is signal and location: confirm coverage at the site, and be ready to tell a dispatcher exactly where the crew is working, since a rural address may not lead an ambulance to a job at the back of a lot.

Eyewash and drenching: (g)

Paragraph (g) says that where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body must be provided within the work area for immediate emergency use. This connects to the hazardous chemicals covered in our hazard communication page, because the safety data sheet is where a crew learns what a product can do to eyes and skin.

Heat emergencies and first aid

First aid planning should include outdoor hazards. NIOSH says heat stroke is fatal if treatment is delayed and calls for a 911 call, moving the worker to a cool shaded area and cooling the worker quickly. Our heat illness page goes through the signs and first-aid steps for each condition.

Common mistakes

  • Waiting until an injury happens to find the nearest hospital.
  • Assuming a small crew is exempt from the first-aid trained worker requirement when no clinic is reasonably accessible.
  • Keeping a kit that is not weatherproof or has not been checked weekly on each job.
  • Relying on a phone without confirming it works at the site and that the location can be given to a dispatcher.
  • Using corrosive products without drenching or flushing facilities in the work area.

When to get professional help

First-aid and CPR training, kit contents and emergency action plans should come from a qualified provider, and decisions about whether a clinic is reasonably accessible should be reviewed with a safety professional. This page summarizes 1926.50 and the regulation text controls.

Sources

Sources checked Nov 23, 2026.

Related

Fall protection and ladder basics · OSHA trench protection basics · OSHA competent person for excavations · All PA site work regulations

Talk to us about your project

FAQ

When must a first-aid trained person be on the job site?

Section 1926.50(c) says that if no infirmary, clinic, hospital or physician is reasonably accessible to treat injured employees, a worker with valid first-aid training must be present at the worksite.

How often must a first aid kit be checked?

Section 1926.50(d)(2) says the employer must check it before each job and at least weekly on each job to replace used items, and the kit must be in a weatherproof container with individually sealed packages for each type of item.

What does 1926.50 say about 911 and phone numbers?

Paragraph (f) requires posted physician, hospital and ambulance numbers where 911 is unavailable. Where 911 is available and a communication system is used, the system must work and the worksite location must be posted where it is not automatically provided.

When are eyewash facilities required?

Section 1926.50(g) requires suitable facilities for quick drenching or flushing of the eyes and body within the work area where they may be exposed to injurious corrosive materials.

General information only, not legal or safety advice. Employers must follow the current OSHA standard and applicable Pennsylvania rules. Source pages checked Nov 23, 2026.