Low-Voltage Landscape Lighting Basics: Transformers, Wire and Voltage Drop
Low-voltage landscape lighting basics
A low-voltage landscape lighting system steps household power down to 12 volts at a transformer, then sends it through buried cable to path, wall, deck and accent fixtures. This guide covers the parts of a system, how a transformer is sized, why long wire runs make the last light dim, and where a licensed electrician has to be involved.
How a low-voltage system works
One general reference on landscape lighting notes that low-voltage fixtures run at 12 V in the United States, while line-voltage fixtures run at 120 V. A basic system has four parts: a transformer, cable, the fixtures, and some form of control. Controls can be timers, photocells (light-sensor switching), motion sensors, manual switches or remote systems. The transformer plugs into a ground-fault (GFCI) outlet, and the manufacturer guidance we reviewed says to place it within 8 feet of a standard GFCI outlet.
Cable burial depth and cable type are code questions for your municipality and your installer, and this page does not give figures for them. Ask which fixtures need buried cable and which can use above-ground cable before anyone trenches.
Common fixture types
| Type | What it is |
|---|---|
| Path and area lights | Common low-voltage fixtures for walkways and beds |
| Uplights | Directional, spot and flood lights, including stake-mounted units; tree lights can point up or down |
| In-grade lights | Buried flush with the surface |
| Wall, deck and hardscape lights | Mounted on walls and decks or built into walls |
| Step lights | Recessed into stair risers |
| Well lights | Set below grade |
Sizing the transformer
Kichler, a lighting manufacturer, states the rule plainly: the total VA of the system should not exceed the wattage rating of the transformer. Its example is a 300 VA system, which needs a transformer rated at least 300 watts. Each fixture’s VA is listed in its product specifications. As a simple arithmetic illustration, ten fixtures each listed at 20 VA add up to 200 VA, so the transformer’s rating has to be at least 200. Add up the real numbers from your spec sheets, and leave room if you expect to add lights later.
Wire runs and voltage drop
Power is lost as it travels through cable. Kichler gives this formula: voltage drop equals 2 times the cable length times the total VA on the run, divided by a cable constant that depends on wire gauge. The end fixture voltage is the transformer tap voltage minus that drop, and Kichler says it should be greater than 10 V. Fixtures on each run should operate within 9 to 15 V.
The formula shows why design matters. A longer run or more VA on one run means more drop, and the lights at the far end are the first to look dim. Kichler lists the usual fixes if the end voltage is too low:
- Move to the next higher transformer tap. Tap voltages are 12, 13, 14 or 15 V.
- Remove fixtures from the run and recalculate.
- Use a larger wire gauge. Kichler suggests starting with 12 gauge and stepping up if needed.
The cable constants come from the manufacturer’s chart, so use the numbers for the wire you are buying.
Placement and safety
- Mount the transformer at least 12 inches above ground.
- Keep it at least 10 feet from any pool or pond (Kichler guidance; check your local code too).
- Call 811 before digging trenches or driving stakes. PA One Call lets homeowners submit a locate request for a residential property.
- Pennsylvania’s Uniform Construction Code does not treat adding or relocating electric wiring as an ordinary repair, so ask your municipality whether a permit or electrical inspection applies.
Planning the layout
Start with what the lights are for: safety on steps and paths, accent on a tree or wall, or security. Use the fewest fixtures that do the job and aim them so light lands on the surface, not the neighbor’s window. The Wikipedia article on landscape lighting notes that light pollution comes from excessive, misdirected or obtrusive light. Then sketch the cable path, split the fixtures into runs of similar load, and check each run’s voltage drop before you buy the transformer. See our guide to LED vs halogen landscape lighting for how lamp choice changes the load.
Questions
What voltage is low-voltage landscape lighting?
In the United States, low-voltage landscape fixtures run at 12 V, compared with 120 V for line-voltage fixtures. A transformer steps the household voltage down.
How big a transformer do I need?
Kichler says the total VA of the fixtures should not exceed the wattage rating of the transformer. For example, a 300 VA system needs a transformer rated at least 300 watts.
Why is the last light on my run dim?
Voltage drops along the cable. Kichler says the end fixture should see more than 10 V. Fixes include a higher transformer tap, fewer fixtures on the run, or heavier wire.
Can I wire the transformer myself?
The 120-volt side is household wiring, so a licensed electrician and local code apply. This page does not give wiring instructions.
Sources
- Kichler, calculating your project load size
- Wikipedia, Landscape lighting (general reference)
- 34 Pa. Code section 403.62, Permits
- Pennsylvania 811 (PA One Call)
Planning outdoor lighting around a patio or wall?
We build the patios, walls and walkways that lighting goes into across central PA. Tell us what you are planning.
Get a quotePlanning information only, not engineering or electrical advice. Fixtures, transformers and local code vary; follow the manufacturer’s instructions and use a licensed electrician for electrical work. Sources checked Nov 23, 2026.