What Is Batter in a Retaining Wall? Degrees, Inches Per Foot and How to Check It
Batter is the backward lean built into a retaining wall face so the wall tilts into the hill it holds. It is set by how far each course steps back from the one below. Batter is measured in degrees from vertical, or in inches of lean per foot of wall height.
The math
Batter comes from the setback of each course and the height of the block. Two formulas cover it:
- Inches per foot = setback per course x (12 / course height in inches)
- Degrees = arctangent of (setback / course height)
Worked out for a common 8-inch-tall block:
- 3/4 inch setback per course = about 1.1 inches per foot = about 5.4 degrees
- 1 inch setback per course = 1.5 inches per foot = about 7.1 degrees
For quick conversions the other way, 1 inch per foot is about 4.8 degrees and 2 inches per foot is about 9.5 degrees. These are our calculations from the formulas above. Your block’s actual setback is set by its lip, pin or shape, so use the manufacturer’s number for the exact product you are buying.
Quick check with a level
- Rest a 4-foot level on a lower course against the face.
- Tilt it until the bubble reads plumb.
- Measure the gap at the top between the level and the wall. That is the batter over 4 feet.
- Compare it to the setback times the number of courses the level spans, and check several spots.
For the why, the tiered-wall rules and what a wall that has lost its lean means, read the full article on retaining wall batter.
In the field
Set the first course dead level, front to back and along its length, before anything else goes on. Batter builds up one course at a time, so any error at the bottom gets repeated in every course above it. When you measure a finished wall, take the reading at the same marked spots each time and write down the gap. A single reading tells you little. The change between readings is what shows movement. For what a plumb or outward-leaning reading means, see the batter article linked above.
Batter FAQ
How much batter should a retaining wall have?
As much as the block is designed for. Each course steps back a fixed amount set by the block, which adds up to several degrees of lean. Use the manufacturer’s setback number for your block.
What decides how much a wall leans?
The setback of each course, which the block’s lip, pin or shape fixes, and the height of the block. Add the steps up the wall and you get the batter. The step itself is defined under setback.
Can a wall have zero batter?
Some systems and stone walls are built near vertical, but they are designed for it. A block wall built plumb by mistake is a problem, because it will look leaning outward as soil pressure moves it.
Sources
- CMHA, Tech Note SRW-TEC-004, Segmental Retaining Wall Design (general SRW design reference)
- Conversions above are calculated from the stated formulas. Confirm setback with your block manufacturer’s installation manual.
Keep reading
- Hardscape and Site Work Glossary
- Related terms: Geogrid and Backfill
- Retaining Wall Batter: Why a Good Wall Leans Back on Purpose
Wall leaning more than it should? Contact Muthler Landscaping & Construction and we will take a look.