Guides · Deck code rules · Frost depth
Frost depth for deck footings in Pennsylvania
The code does not hand you one number. It says footings go below the frost line, and that line is set locally. This page shows exactly what the model IRC and the AWC deck guide say, and what we could not find a statewide figure for.
The model IRC requires deck footings to extend below the frost line in Table R301.2(1) (R507.3.2). The AWC DCA 6 guide says at least 12 inches below grade, or below the frost depth if deeper (p. 11). We did not find a single statewide Pennsylvania frost depth in the sources checked, so ask your municipal code office for the local figure.
What the sources say
| Source | Statement | Section |
|---|---|---|
| Model IRC | Deck footings extend below the frost line specified in Table R301.2(1). | R507.3.2 (see R403.1.4) |
| Model IRC | The frost line is a value each jurisdiction fills in on Table R301.2(1) when it adopts the code. | Table R301.2(1) |
| AWC DCA 6 | Footings bear on undisturbed soil at least 12 inches below grade, or below the frost depth if deeper. Confirm with the authority having jurisdiction. | p. 11 |
| Model IRC exception | A free-standing deck may skip frost-depth footings only if joists bear on precast pier blocks at grade, no beams or posts, 200 sq ft or less, and no more than 20 inches above grade. | R507.3.2 |
What this means for a PA deck
Call the municipal code office or the building code official who will inspect your deck and ask for the frost depth they use. That is the figure that governs your footing.
If the local frost depth is more than 12 inches, the AWC guide says to go below it (p. 11).
Most footing questions come up at the permit stage. See when a deck needs a permit in Pennsylvania.
Related: deck footing requirements, concrete per post hole, frost line depth in Pennsylvania and PA 811 before you dig.
Questions
What is the frost depth in Pennsylvania?
We did not find a single statewide figure in the sources we checked. The model IRC makes it a local value in Table R301.2(1), so your municipal code office sets the number.
Is 12 inches deep enough for a deck footing?
The AWC guide says 12 inches below grade, or below the frost depth if that is deeper (DCA 6, p. 11). If your local frost depth is more than 12 inches, go below it.
Can I skip frost-depth footings?
Only a free-standing deck that meets every limit in R507.3.2: pier blocks at grade, no beams or posts, 200 sq ft or less, and 20 inches or less above grade.
Sources: American Wood Council, DCA 6 (2015); Penn State Housing Research Center, deck design handout; 2018 IRC deck construction summary; PA L&I, UCC regulations and statutes. Checked Nov. 22, 2026.
Muthler Landscaping & Construction · Lock Haven, PA
Planning a deck?
We build decks across central Pennsylvania. Tell us what you have in mind.
Get a quoteAll guidesMuthler Landscaping & Construction LLC · 913 Bellefonte Ave, Lock Haven, PA 17745 · (570) 397-9800 · PA HIC #PA212584.