Runoff Capture and Reuse (Cisterns): What the PA Stormwater BMP Manual Says

Home / Drainage guides / Runoff capture and reuse

Runoff capture and reuse (cisterns): how the PA BMP Manual describes it

Quick answer: In the Pennsylvania Stormwater Best Management Practices Manual, BMP 6.5.2 Runoff Capture and Reuse covers cisterns, rain barrels and other storage that holds roof runoff for later use. It needs a water budget and an overflow, and the manual does not advise drinking the water without treatment.

What it is

BMP 6.5.2 covers cisterns of 500 gallons or more, rain barrels, vertical storage and storage beneath structures. The manual lists uses such as irrigation, firefighting, combined-sewer peak reduction, greywater (including toilet flushing) and athletic field irrigation. Storage is meant to capture small, frequent storms, a water budget is required, and a bypass or overflow must handle large storms. For the homeowner-scale barrel picture in Pennsylvania, see our page on rain barrels and rainwater harvesting.

Key design points

ItemWhat the manual says
Storage pressure0.43 psi per foot of water, so a 10-foot tank gives 4.3 psi
Irrigation pressureAt least 15 psi, so a pump, pressure tank and fine mesh filter may be needed
Buried cisternsObservation risers at least 6 inches above grade
OverflowOutlet a few inches below the top of the cistern
CoversTight fitting, with light limited to reduce algae
LabelingPipes and tanks marked “Caution: Reclaimed water, Do Not Drink”
PlumbingSeparate from potable lines, no connection to domestic or commercial potable systems

The manual also asks designers to consider freeze protection and drawdown between storms, and offers first-flush diversion as optional. Its worked example is a 2,000 square foot lawn watered at 1 inch per week for 4 months. Stated performance is Medium/High volume reduction, Low recharge and Medium peak rate control. The volume reduction equals the container volume, adjusted for how often it empties.

How it reduces runoff

The manual gives no formulas for this practice. Volume reduction equals the container volume, adjusted for how often the container empties, so a barrel that is always full does nothing for the next storm. Pollutant removal is said to depend on design, with filtration and soil infiltration depending on flow rate, soil type and design. The manual says rooftop runoff carries very low concentrations of pollutants in one design consideration, but it still calls for screening and periodic cleanout, so plan for debris, leaves and algae rather than assuming the water arrives clean.

Construction and maintenance

The construction section says only to install per the manufacturer’s instructions. Maintenance is to flush and brush cisterns, then disinfect, and to empty devices before freezing. Tanks and sumps need periodic cleanout. Vertical storage containers must meet FDA drinking-water specifications if potable use is intended.

Where the manual contradicts itself

  • Pollutant removal: the table lists 100% for TSS, TP and nitrate, while the text says removal depends on design. The water quality row is also blank and misaligned.
  • Drinking water: the description says potable reuse is not advised without treatment, the specification allows potable use in FDA-compliant tanks, and the labeling rules say the water is not drinkable.
  • Roof runoff quality: one place says rooftop runoff has very low pollutant concentrations, while the vegetated roof section says roof runoff is often a contributor to nonpoint source pollution.
  • Old cost figures (2005): rain barrels $80 to $200, average $150; vertical storage $88 for 64 gallons and $10,516 for 12,000 gallons; and a stated $1.25 per gallon. The per-gallon rate does not match the listed prices (12,000 gallons at $1.25 would be $15,000). Treat all as dated.

Pennsylvania approvals and who designs it

Plumbing connections, any indoor reuse and cross-connection protection need a licensed professional and local plumbing approval. A cistern used for stormwater credit may need approval from your municipality, the county conservation district or DEP. Check the rules in PA stormwater plan rules and rain barrel laws by state.

Sources

  • Pennsylvania Department of Environmental Protection, Pennsylvania Stormwater Best Management Practices Manual (363-0300-002, December 30, 2006), BMP 6.5.2 Runoff Capture & Reuse, via the PA DEP eLibrary (greenport.pa.gov). Checked Nov 23, 2026.

Related

All drainage guides · Outdoor features · Install a dry well

Get a quote

FAQ

What size is a cistern in the PA BMP Manual?

The manual describes cisterns as 500 gallons or more, separate from rain barrels.

Can captured roof water be used for drinking?

The manual says potable reuse is not advised without water treatment, and requires the labeling Caution: Reclaimed water, Do Not Drink.

Is a tank overflow required?

Yes. The manual says a bypass or overflow must handle large storms, with the overflow outlet a few inches below the top of the cistern.

What pressure does an irrigation system need?

The manual says at least 15 psi, while a 10-foot tank gives only 4.3 psi, so a pump may be needed.

Planning information only. Design must be done by a qualified professional and approved by your municipality and, where required, DEP. Source checked Nov 23, 2026.