Articles November 18, 2026 9 min read

Snow Melt System for Pavers: Electric vs Hydronic, Where It Pays and How It’s Built

A paver snow melt system is electric cable or hydronic tubing buried in the bedding sand or top of the base, switched on by a snow sensor. Electric costs less to put in and more to run; hydronic is the reverse. Plan it before the build, because adding one later means lifting the pavers.

A snow melt system for pavers is electric heating cable or hydronic tubing buried under the pavers, in the bedding sand or the top of the compacted base, with a sensor that turns it on when snow starts. Plan it before the patio, walk or driveway is built, because adding one later means lifting the pavers and bedding. As general practice, heat the steps and walks you have to use in winter rather than a whole open area, since every heated square foot adds to the running cost.

Quick answer

Electric: cable or mats in the sand, with at least 1 1/2 inches of sand over them (SunTouch). Cheaper to install, costly to run. Hydronic: water and glycol in tubing, heated by a boiler or other source. Costlier to install, cheaper to run. Base: at least 6 inches of compacted stone under walks, 10 inches under driveways (CMHA). Retrofit: lift the pavers, add the system, relay. Wiring: a licensed electrician, to local code and NEC Article 426.

38 to 50 Wper sq ft for electric cable (SunTouch)
2 inbedding sand it may take to cover cable or tubing (CMHA)
1 in/hrmelt rate CMHA calls usually acceptable at a home

How a snow melt system works under pavers

The Concrete Masonry and Hardscapes Association (CMHA), the paver industry’s trade group, covers these systems in PAV-TEC-012. Heat from the cable or tubing rises through the bedding sand and pavers and melts snow as it lands, though it generally doesn’t dry the surface. The meltwater drains off, so CMHA wants a slope of at least 2 percent and no runoff onto other paving where it can refreeze.

Output is sized to the snowfall rate, temperature and wind. CMHA quotes design guidance that melting 1 inch of snow per hour is usually acceptable at a home. A heavy storm can outrun the system, but CMHA says what’s left is easier to clear off a warm surface.

Controls decide when it runs. CMHA describes a sensor that switches the system on when snow or ice falls, a thermostat in the bedding sand, and sometimes a low idle heat that the sensor turns up. SunTouch says its controls with slab temperature sensing run at the lowest effective melting temperature to reduce operating costs.

Hydronic vs electric snow melt

ElectricHydronic
What’s buriedHeating cable or pre-spaced matsFlexible tubing filled with water and glycol
Cost to installLower (CMHA)Higher (CMHA)
Cost to runSubstantial (CMHA)Lower (CMHA)
Heat sourceDedicated circuits with ground-fault protectionA boiler, or another source such as a heat pump
Where it sits under paversIn sand, at least 1 1/2 in of sand over itUponor lays it about 4 in below the surface
Who installs itA licensed electricianAn experienced plumbing or heating contractor
CMHA PAV-TEC-012, the SunTouch ProMelt manual and Uponor’s Meltaway guide. Your system maker’s design overrides these.

Electric is simpler. The SunTouch ProMelt manual rates its cable at 50 watts per square foot at 3-inch spacing for most moderate and heavy snowfall, and 38 watts at 4-inch spacing for light to moderate snow. The cable can’t be cut or crossed, and every circuit needs ground-fault equipment protection.

Hydronic needs a heat source. CMHA says these systems typically rely on the building’s boiler. Uponor’s Meltaway guide says its system needs water of at least 35°C (95°F), which lets sources such as a heat pump feed it through a heat exchanger, and it spaces the tubing 250 mm (about 10 inches) apart.

Where the cable or tubing sits in a paver build

Sand-set pavers on a stone base

CMHA says a crushed stone base may be the most cost-effective choice for heated walks, patios and home driveways. Its minimums:

  • Base: at least 6 inches of compacted stone for walks and patios and 10 inches for driveways, more on weak or slow-draining soil, with geotextile over clay. That matches the 6 inches of compacted 2A modified we put under patios, more on clay or wet ground; see paver base depth.
  • Heating lines: in the bedding sand, or set into the top inch of the base, flush, so the sand screeds smoothly over them.
  • Bedding sand: normally 1 to 1 1/2 inches, up to 2 inches before compaction to cover the lines. Use concrete sand, never stone dust or screenings, which drain slowly.
  • Insulation: rigid foam under the bedding, for walks and patios only. CMHA says it may be needed over a high water table or on a long, narrow walk, and that under a driveway it can break and trap water.
  • Pavers: 2 3/8 inches thick for walks and home driveways, 3 1/8 inches for heavier vehicle use.

For electric, SunTouch wants at least 1 1/2 inches of sand over the cable and warns that the deeper it sits, the longer it takes to melt from a cold start. More than 4 inches of total mass can make the response unacceptably slow.

Where snow melt cable and tubing go under pavers Where the heat goes under a paver walk Sand-set pavers over a compacted stone base. Not to scale. Electric Hydronic pavers, 2 3/8 in bedding sand, up to 2 in compacted stone base geotextile on clay subgrade about 4 in to the tubing (Uponor) 6 in min, walks 10 in, driveways (CMHA) Cable in the sand 1 1/2 in min sand over it, 3 or 4 in apart (SunTouch) Tubing on the base water and glycol, about 10 in apart (Uponor) muthlerlandscaping.com
Where the heat goes in a sand-set paver build. Layer minimums from CMHA PAV-TEC-012; cable cover from SunTouch; tubing depth from Uponor’s Meltaway guide.

Pavers on a slab, and heated paver driveways

For streets and crosswalks, CMHA puts the lines inside a concrete slab or asphalt, with at least 2 inches of concrete above and below them, and sets the pavers in sand on top with drain holes through the slab. Over an existing slab, check the drainage first; our guide to pavers over concrete covers it.

On a home driveway, CMHA and SunTouch both show heating only the wheel tracks, with full coverage near the garage; CMHA says that lowers the installation cost, though the snow between the tracks may still need clearing. The material choice is covered in pavers vs concrete driveway.

Builder’s note: Have the electrician or heating contractor on site the day the base is finished, before the bedding sand is screeded. Cable and tubing get tested before they’re buried: SunTouch calls for resistance and insulation checks, and CMHA says liquid systems get tested for leaks. A fault found later means pulling the pavers back up.

Pavers being laid in a pattern over a compacted gravel base with a laser level on a tripod
Pavers going down over a compacted stone base on one of our jobs. On a heated patio or walk, the cable or tubing is already buried in the bedding sand or set into the top of the base before this stage.

Heated outdoor steps and walks: where it pays

CMHA lists the payoffs: fewer slips and less liability, less shoveling, less freeze-thaw and deicer damage, and cleaner floors inside. As general practice, that points to the entry steps, landing and main walk.

On steps, SunTouch keeps its cable within 3 inches of the front edge of each tread and at least 6 inches from the sides, and says to mark on the drawings where future railings can safely go. It never goes on wood or composite stairs or in the deck around a pool. Our guide to building paver steps covers the risers and base.

Is a heated patio worth it? For snow, the general practice is to heat only the path you actually use in January. Heating a patio for comfort is a different design: SunTouch says that kind of outdoor heating has to be set in a concrete or mortar slab, never directly in sand, which conducts heat poorly.

Is a heated driveway worth it? That depends on the slope, the length and who has to get out in a storm.

Running cost: do the math before you build

A 4 by 25 foot walk is 100 square feet. At 50 watts per square foot, that’s 5,000 watts, or 5 kilowatts, so it uses 5 kilowatt-hours for every hour it runs. Multiply by your rate per kilowatt-hour and the hours it runs in a winter, idle time included. On 240 volts that load draws about 21 amps (5,000 divided by 240 is 20.8), which falls in the “30 amp circuit for load up to 24 amps” line of SunTouch’s sizing table, since circuits are sized for 125 percent of the load. Your electrician sizes the real circuit.

For hydronic, Uponor’s worked example is a truck loading area: 160 square meters (about 1,722 square feet) designed at 200 watts per square meter, estimated at 26,100 kilowatt-hours of energy a year with 600 hours of snowfall. Ask your system designer to run the numbers for your site.

Snow melt retrofit under existing pavers

CMHA says snow melt can be added after construction. With pavers, that means lifting the surface: pull the pavers and bedding sand, confirm the base is sound and deep enough, lay the cable or tubing, screed new sand and relay the same pavers. CMHA’s maintenance guide calls this unzipping and zipping the pavement. Budget for the conduit and junction box, or the supply lines, manifold and heat source, too.

Who should install it

CMHA says the wiring or tubing should be installed by an electrical or plumbing contractor experienced with these systems, working from the manufacturer’s design. SunTouch says installation must follow local codes and NEC Article 426, and its wiring diagrams say all electrical work must be done by a qualified licensed electrician. Hire a licensed electrician for the wiring, and check with your building or electrical department about permits. This is general information, not legal or electrical advice.

If the patio or walk is still on paper, settle the heated zone, conduit route and drainage first; our online patio design plans set the layout, base depth and pitch everyone builds to.

Frequently Asked Questions

Can you add snow melt under existing pavers?

Yes, by lifting them. CMHA says snow melt can be added after construction: the pavers and bedding come up, the cable or tubing goes in, and the same pavers go back down on new bedding sand.

Is electric or hydronic snow melt better for pavers?

CMHA says electric costs less to install and more to run, and hydronic is the reverse. As general practice, that makes electric the usual pick for small areas like steps and walks, and hydronic worth pricing for larger areas or a home that already has a boiler.

How much does it cost to run a heated paver walkway?

A 100 square foot walk at 50 watts per square foot uses 5 kilowatt-hours each hour it runs; multiply by your electric rate and the hours it runs in a season.

Can heated cable go under paver steps?

Yes, on masonry steps. SunTouch keeps the cable within 3 inches of the front edge of each tread and at least 6 inches from the sides, and says never to use it on wood or composite stairs.

Sources: CMHA PAV-TEC-012, Snow Melting Systems for Interlocking Concrete Pavements (rev. 2022); CMHA PAV-TEC-006, Operation and Maintenance Guide for Interlocking Concrete Pavement; SunTouch (Watts), ProMelt Electric Snow Melting Mats and Cables Installation Manual (2021); Uponor, Meltaway Snow and Ice Melting System for Outdoor Areas, technical information (2017)

Groundwork Design Co. · designed by builders

Plan the whole backyard as one project

Groundwork Design Co. lays out patios, fire pits, walls, lighting and planting for any U.S. yard, drawn to scale and checked by crews who build this work. Full-yard plans are $895.

See backyard designSee sample plans

In central PA? We design and build it. See our fixed-price outdoor living packages.

Published by Muthler Landscaping & Construction, owned by Thayne Muthler (PA HIC #PA212584). How we research and check facts: editorial policy.