PennDOT Riprap Classes R-3 to R-8: Size Ranges and What Pub 408 Does and Does Not Tell You
PennDOT riprap classes R-3 to R-8
Quick answer: Penn State and a Pennsylvania producer list riprap as R-3 through R-8, from 2 to 6 inch stone up to 15 to 42 inch stone. PennDOT’s Pub 408 puts rock lining in Section 850, and this page gives sizes only.
What riprap means in Pennsylvania
Penn State’s Aggregate 101 bulletin calls riprap a generic term for open-graded rock larger than AASHTO No. 1 stone, typically used to stabilize banks, channels and outlets. In Pennsylvania, that rock is usually ordered by an R-class number. This page lays out what the R-classes are, which sources describe them, and where the sources do not line up. For a plain-language definition, see what riprap is.
The R-class size table
The Penn State Center for Dirt and Gravel Roads Studies lists these as “Common Rip-Rap Specifications in PA” in its March 2025 Aggregate 101 appendix. A Pennsylvania stone producer’s spec sheet shows the same six rows.
| Class | Size range (in.) | Average size (in.) | General use listed |
|---|---|---|---|
| R-3 | 2 to 6 | 3.5 | Road subbase |
| R-4 | 3 to 12 | 7 | Ditches |
| R-5 | 4 to 18 | 11 | Streambanks and ditches |
| R-6 | 9 to 24 | 14 | Streambanks |
| R-7 | 12 to 30 | 20 | Streambanks |
| R-8 | 15 to 42 | 28 | Abutments |
Both sources also show a gradation row for each class that reads 100, then 15 to 50, then 0 to 15. This page leaves those numbers out of the table on purpose, so check the project spec for gradation.
Loose terms: surge, gabion and shot rock
The same sources say surge, gabion and shot rock are relatively loose terms with broader size ranges and no exact specification. The producer sheet describes gabion as 4 to 8 inches (used for baskets and ditches), surge as about 10 inches and finer (subbase and fill), and shot rock as up to 24 inches. If a plan says “gabion stone” or “surge,” ask the supplier what size they actually mean, because there is no PennDOT class behind the word.
Where the sources disagree on the governing section
- Penn State’s Aggregate 101 says most Pennsylvania aggregate specifications can be found in PennDOT Publication 408, Section 703. It also says the “R” designations are set by the National Crushed Stone Association.
- A PennDOT-hosted research report on partially grouted riprap cites “Section 850, Rock Lining” for riprap, with size and gradation under Section 850.2(a)2 and a requirement to use only Class R-6 rock on that project.
- Pub 408/2020 Change No. 2, Section 703.5(a), as copied into Penn State’s Aggregate Course Book, tells the reader to accept AASHTO No. 1 coarse aggregate as specified in Section 850.2(a)1.
Reading these together, Section 703 covers aggregates in general while Section 850 is where PennDOT’s rock lining requirements appear. This page gives no Section 850 numbers.
Modified R-classes in the research report
The same research report refers to modified classes R-5M, R-6M and R-7M for grouted riprap. This page does not publish their d50 and nominal thickness values. If you need them, read the report itself.
What goes under riprap
In that research report’s specification, the filter is a 6 inch layer of AASHTO No. 57 Type A coarse aggregate placed on a Class 4, Type A nonwoven geotextile under Section 735, with a 2 inch No. 57 leveling layer beneath the fabric. It says the fabric must be placed without voids, gaps, tears or holes, and that damaged fabric must be repaired or replaced. That is one project’s specification, not a universal rule for every riprap job. See PennDOT geotextile classes for the fabric side.
Pub 408 editions
PennDOT’s Publication 408 index lists these editions: 2016 (April 1, 2016 to April 2, 2020), 2020 (April 10, 2020 to October 10, 2025) and 2026 (April 10, 2026 to April 12, 2030). The Section 703 excerpt above comes from the 2020 edition, Change No. 2. A class or number may differ in the 2026 edition. The edition named in your bid documents controls.
Common mistakes
- Ordering by the R-number without confirming the supplier’s size range matches the plan.
- Treating “gabion” or “surge” as a PennDOT class.
- Assuming a grouted-riprap project’s R-6 requirement applies to a dry-stacked slope.
- Skipping the fabric or leaving tears under the stone.
For weight per cubic yard, see riprap weight per yard.
Sources
- Penn State Center for Dirt and Gravel Roads Studies, DSA Handbook Appendix F (3/2025)
- Penn State, Aggregate 101 technical bulletin
- Braen Stone, Common Rip Rap Specs in PA
- PennDOT research report, Environmental and Cost Effectiveness of Partially Grouted Riprap for Scour Countermeasure
- Penn State Aggregate Course Book 2022-23 (copies Pub 408/2020 Change No. 2, Section 703)
- PennDOT Publication 408 edition index
Related
All aggregates · AASHTO No. 57 stone · What is riprap · Riprap weight per yard
FAQ
What are the PennDOT riprap classes?
Penn State and a Pennsylvania producer list R-3 through R-8, from R-3 at 2 to 6 inches up to R-8 at 15 to 42 inches. Check the project spec for gradation.
Which Publication 408 section covers riprap?
Penn State points to Section 703 for aggregates generally. A PennDOT-hosted research report cites Section 850, Rock Lining, for riprap size and gradation.
What fabric goes under riprap?
One PennDOT research specification calls for a Class 4, Type A nonwoven geotextile under Section 735 with a 6 inch No. 57 filter layer. Your project spec governs.
Is gabion stone a PennDOT class?
No. Sources say gabion, surge and shot rock are loose terms with no exact specification.
Planning information only. The project specification and your engineer or inspector govern. Sources checked Nov 23, 2026.